Общая информация (PWR-C45-6000ACV)
PWR-C45-6000ACV is a Cisco Catalyst Switch 4500 Series Switch Power Supply, delivering 6000W AC power (Data and PoE) for Cisco 4500 switches. Notice that PWR-C45-6000ACV= is similar with PWR-C45-6000ACV, except that PWR-C45-6000ACV= is a spare one.
Быстрые спецификации
Table 1.
Product Code |
PWR-C45-6000ACV |
Manufacturer |
Cisco System Inc. |
Product Type |
Power Supply Module |
Compatible product |
Cisco Catalyst 4500-E Series Switches and classic chassis |
Power Input |
2800W Data and 4200W PoE Power |
Auto-Sensing |
110V (15A) / 220V (20A) |
Redundancy |
Dual input power supply for additional redundancy |
Rated MTBF (Hours) |
341,356 |
Детали продукта
Figure 1. PWR-C45-6000ACV can be installed in the Catalyst 4500 switch Chassis.
Compatible Products
Table 2. Recommended Compatible Switches.
Model |
Description |
WS-C4503-E |
Cat4500 E-Series 3-Slot Chassis, fan, no ps |
WS-C4507R-E |
Cat4500 E-Series 7-Slot Chassis, fan, no ps, Red Sup Capable |
WS-C4510R-E |
Cat4500 E-Series 10-Slot Chassis, fan, no ps,Red Sup Capable |
WS-C4507R+E |
Catalyst 4500E 7 slot chassis for 48Gbps/slot - Supervisor Engine redundancy - Power redundancy |
WS-C4506-E |
Catalyst 4500 E-Series 6-Slot Chassis, fan, no ps |
Сравнение с аналогом
Table 3. Comparison of similar item.
Product Code |
PWR-C45-6000ACV |
PWR-C45-4200ACV |
Manufacturer |
Cisco System Inc. |
Cisco System Inc. |
Product Type |
Power Supply Module |
Power Supply Module |
Compatible product |
Cisco Catalyst 4500-E Series Switches and classic chassis |
Cisco Catalyst 4500-E Series Switches and classic chassis |
Power Input |
2800W Data and 4200W PoE Power |
4200W AC dual input |
Rated MTBF (Hours) |
341,356 |
331,945 |
Что бы получить больше информации
У вас есть какие-либо вопросы о PWR-C45-6000ACV?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
kVA rating5 | 6.8 kVA (power factor = 0.99) |
INPUT OK | Green—Source AC voltage is OK. (Input voltage is 85 VAC or greater.) Off—Source AC voltage falls below 70 VAC, is not present, or the power supply is turned off. |
AC-input type | Autoranging inputs with power factor correction Note Power factor correction is a standard feature on all Catalyst 4500 E-series AC-input power supplies. PFC reduces the reactive component in the source AC current allowing higher power factors (typically 99 percent or better) and lower harmonic current components. |
AC-input voltage | Low-line (120 VAC nominal)—85 VAC (min) to 132 VAC (max) High-line (230 VAC nominal)—170 VAC (min) to 264 VAC (max) |
AC-input current | 12 A (max) @ 120 VAC (for each input) 16 A (max) @ 230 VAC (for each input) |
AC-input frequency | 50/60 Hz (nominal) (±3% for full range) |
Power supply output | Total output depends on the number of inputs connected and the source AC voltage. If two inputs are used, they should both be of the same AC voltage. 1050 W operation (with one 120 VAC nominal input) – 70.8 A @ 12 VDC (data only) – 12.5 A @ 3.3 VDC (data only) – 18.4 A @ –50 VDC (PoE if used) 2100 W operation (with two 120 VAC nominal inputs) – 141.6 A @ 12 VDC (data only) – 12.5 A @ 3.3 VDC (data only) – 37.0 A @ –50 VDC (PoE if used) 3000 W operation (with one 230 VAC nominal input) – 183.3 A @ 12 VDC (data only) – 12.5 A @ 3.3 VDC (data only) – 48 A @ –50 VDC (PoE if used) 6000 W operation (with two 230 VAC nominal inputs) – 183.3 A @ 12 VDC (data only) – 12.5 A @ 3.3 VDC (data only) – 96 A @ –50 VDC (PoE if used) |
Power supply output capacity | 6000 W maximum |
Output holdup time | 20 ms minimum |
Heat dissipation | 2,720 BTUs/hr (approx.) |
Minimum software requirement | Cisco IOS Release 12.2(52)SG |
Power over Ethernet | Supported, up to 4800 W |
FAN OK | Green—Power supply fan is operating properly. Off—Power supply fan failure is detected. |
OUTPUT FAIL | Red—Problem with one or more of the DC-output voltages of the power supply is detected. Off—DC-output voltage with acceptable margins. Note For proper operation of the OUTPUT FAIL LED, systems with single power supplies must be configured with a minimum of one fan tray assembly and one supervisor engine. Systems with dual power supplies must have a minimum configuration of one fan tray assembly, one supervisor engine, and one additional module. Failure to meet these minimum configuration requirements can cause a false power supply output fail signal. |