Huawei S5720-52P-EI-AC Gigabit Switch provides resilient, energy-efficient GE ports for access switching in data centers, and aggregation switching in enterprise campus networks. With fourty-eight 10/100/1,000 Base-T Ethernet ports and four 1,000 Base-X SFP ports, its performance enhancements include advanced processing hardware, 10 Gbit/s uplink ports, and large MAC address and routing tables; Super Virtual Fabric (SVF) support enables intelligent virtualization, iStack clustering, and operation in N + 1 backup mode for simplified O&M and high availability. Mature IPv6 features ensure smooth migration to next-generation IP networking.
Быстрые спецификацииs
На рисунке 1 показан внешний вид Huawei S5720-52P-EI-AC switch.
Таблица 1 показывает Быстрые спецификацииs.
Product Code |
S5720-52P-EI-AC |
Fixed Ports |
48 x 10/100/1,000 Base-T, 4 Gig SFP |
Extended Slots |
Not supported |
Memory (RAM) |
2 GB |
Flash |
340 MB |
MAC Address Table Size Forwarding Performance |
64 MAC |
Forwarding Performance |
78 Mpps |
Switching Capacity |
598 Gbit/s |
Power Supply |
AC power supply, supporting RPS |
Voltage Required |
AC Rated voltage range: 100V to 240V AC, 50/60 Hz Maximum voltage range: 90V to 264V AC, 47 Hz/63 Hz |
Front Power Input |
No |
Typical Power Consumption |
51.1W |
Dimensions (W x D x H) |
442 mm x 420 mm x 43.6 mm |
Weight |
4.66kg |
Детали продукта
На рисунке 2 показана передняя панель Huawei S5720-52P-EI-AC switch.
Note:
? |
Forty-eight 10/100/1000BASE-T ports |
? |
Four 1000BASE-X ports |
? |
One ETH management port |
? |
One mini USB port |
? |
One console port |
? |
One USB port |
* The console port is used with a console cable. The console cable is not delivered with the switch and needs to be separately purchased if needed.
На рисунке 3 показана задняя панель Huawei S5720-52P-EI-AC switch.
Note:
? |
Ground screw |
? |
Two QSFP+ stack optical ports |
? |
RPS socket |
? |
AC socket |
*The ground screw is used with a ground cable.
* The RPS socket is used with an RPS cable, which is not hot swappable.
*AC socket is used with an AC power cable.
Optical Modules
Table 2 shows the recommended optical modules.
|
Model |
Description |
GE-SFP Optical Transceiver |
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm,0.55km,LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,10km,LC) |
|
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,40km,LC) |
|
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm,40km,LC) |
|
GE copper transceiver |
SFP-1000BaseT |
Electrical Transceiver, SFP , GE ,Electrical Interface Module(100m,RJ45) |
Compare with Similar Item
Table 3 shows the comparison of Huawei S5720-32P-EI-AC, S5720-52P-EI-AC and S5720-52X-EI-AC.
Models |
S5720-32P-EI-AC |
S5720-52P-EI-AC |
S5720-52X-EI-AC |
Fixed Ports |
24 x 10/100/1,000 Base-T, 4 x 100/1,000 Base-X SFP, 4 Gig SFP |
48 x 10/100/1,000 Base-T, 4 Gig SFP |
48 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ |
Extended Slots |
NA |
NA |
NA |
Power Supply |
AC power supply, supporting RPS, power socket on the front panel |
AC power supply, supporting RPS | AC power supply, supporting RPS |
Forwarding Performance |
48 Mpps |
78 Mpps |
132 Mpps |
Switching Capacity |
598 Gbit/s |
598 Gbit/s |
598 Gbit/s |
Front Power Input |
AC: Yes |
AC: No |
No |
Power Consumption |
39.8W |
51.1W |
52.3W |
Comparison between LI, SI, EI and HI
Huawei S5720 Series Enterprise Switches provides LI (Lite), SI (Standard), EI (Enhanced) and HI (Hyper) models for users. There are some differences among these four versions.
Click this PDF to know more.
Comparison of Huawei S5720-LI, SI, EI and HI Series Switches.pdf
Get More Information
Do you have any question about the Huawei S5720-52P-EI-AC switch?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
Input voltage | AC: Rated voltage range: 100 V to 240 V A C, 50 Hz to 60 Hz Maximum voltage range: 90 V to 264 V A C, 47 Hz to 63 Hz DC: Rated voltage range: –48 V to –60 V, DC Maximum voltage range: –36 V to –72 V, DC |
Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM MSDP MVPN |
Security | Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, port number, and VLAN ID Port isolation, port security, and sticky MAC MFF Blackhole MAC address entries Limit on the number of learned MA C addresses IEEE 802.1x authentication and limit on the number of users on a port AAA authentication, RADIUS authentication, and HWTACACS authentication NAC SSH v2.0 HTTPS CPU defense Blacklist and whitelist Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and M LD packets |
VLAN | 4K VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports 1:1 and N:1 VLAN mapping VLAN-based transparent transmission of protocol packets |
Extended slot | NA |
Super Virtual Fabric (SVF) | Plug-and-play SVF client Automatic software and patch loading to clients One-click and automatic delivery of service configurations Independent client running |
Management and Maintenance | iStack Virtual cable test SNMP v1/v2c/v3 RMON/RMON2 Web-based NMS System logs and alarms of different levels sFlow 802.3az Energy Efficient Ethernet (EEE) |
MAC address table | IEEE 802.1d 64K MAC address entries MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses |
IP routing | Static routing, RIPv1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, and policy-based routing |
Interoperability | VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST Link-type Negotiation Protocol (LNP), similar to DTP VLAN Central Management Protocol (VCMP), similar to VTP |
IPv6 features | Neighbor Discovery (ND) Path MTU (PMTU) IPv6 ping, IPv6 tracert, and IPv6 Telnet 6to4 tunnel, ISATAP tunnel, and manually configur ed tunnel ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or pr otocol type MLD v1/v2 snooping |
Operating environment | Operating temperature: 0-1800 m altitude: 0oC to 45oC 1800-5000 m altitude: The operating temperature reduces by 1oC every time the altitude increases by 220 m. Relative humidity: 5% to 95% (non-condensing) |
Jumbo frame | 12K |
Reliability | Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag) ITU-Y.1731 BFD for BGP, BFD for IS-IS, BFD for OSPF, BFD for static route VRRP4, VRRP6 |
QoS/ACL | Rate limiting on packets sent and received by a port Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues on each port WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms WRED Re-marking of the 802.1p priority and DSCP priority Packet filtering at Layer 2 to Layer 4, filtering out invalid fr ames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Rate limiting in each queue and traffic shaping on ports 1:1, N:1, N:4 port mirroring |
Fixed ports | S5720-52P-EI-AC: 48 10/100/1000Base-T, 4 Gig SFP, 2 QSFP+ |
Ethernet loop protection | RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover SEP ERPS (G.8032) STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) BPDU protection, root protection, and loop protection BPDU tunnel |
TWAMP | Two-way IP link performance measurement Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter |
Dimensions (W x D x H, mm) | 442 220 43.6 |
Front power input | S5720-52P-EI-AC: No |
Typical power consumption | S5720-52P-EI-AC: 51.1 W |
MPLS | MPLS L3VPN MPLS L2VPN (VPWS/VPLS) MPLS-TE MPLS QoS |