Общая информация (S5700-28C-HI)
The S5700-28C-HI is advanced Ethernet switch based on new generation of high-performance hardware and Huawei Versatile Routing Platform (VRP). With 24 GE ports (10/100/1000Base-T), it provides a large switching capacity, high-density GE interfaces for users, besides, it can be equipped with multiple types of card modules and power modules to meet the different demands of users. All these features make the S5700-28C-HI the best choice as an access switch on large and medium-sized campus networksdata centers and aggregation switch on small campus networks. The S5700-28C-HI integrates many advanced technologies in terms of reliability, security, and energy conservation in order to help enterprise customers build a next-generation IT network.
Быстрые спецификацииs
На рисунке 1 показан внешний вид Huawei S5700-28C-HI switch.
Note:
Product Code |
S5700-28C-HI |
Ports |
24 × 10/100/1,000 Base-T ports |
Extended Slots |
1 extended slot |
Memory (RAM) |
512 MB |
Flash |
64 MB |
MAC Address Table Size |
32 MAC |
Subcard Supported |
4 x 1,000 Base-X SFP subcard 2 x 10 GE SFP+ subcard 4 x 10 GE SFP+ subcard |
Voltage Required |
AC: Rated voltage range: 100V to 240V, 50/60 Hz Maximum voltage range: 90V to 264V, 50/60 Hz DC: Rated voltage range: –48V to –60V, DC Maximum voltage range: –36V to –72V, DC |
Power Device |
Do double hot-swappable AC/DC power supplies |
Power Consumption Operational |
<76 W |
Forwarding performance |
96 Mpps |
Switching capacity |
256 Gbit/s |
Dimensions (W x D x H) |
442 mm x 220 mm x 43.6 mm |
Package Weight |
4.2 kg |
PoE |
Not supported |
Детали продукта
На рисунке 2 показана передняя панель HuaweiS5700-28C-HI switch.
Note:
? |
Power module slot 1 |
? |
Power module slot 2 |
? |
ESD jack |
? |
One console port |
? |
ETH management port |
? |
USB port |
? |
Twenty-four 10/100/1000BASE-T ports |
? |
Front card slot |
* The front card slot is equipped with the card module, but the card module should be purchased separately.
*Before installingmaintaining a switch, wear an ESD wrist strap and insert the other end of the ESD wrist strap into this ESD jack.
* The power module slot 1 has been installed with the DC power module.
* The power module slot 2 has been installed with the AC power module.
На рисунке 3 показана задняя панель Huawei S5700-28C-HI.
Note:
? |
Ground screw |
? |
Monitoring port |
* The ground screw is used with a ground cable. The switch has two ground screws, any of which can be used to install a ground table.
* The monitoring port monitors the cabinet door, power module, battery power, and power supply of the air conditioner.
Recommended Modules
Table 2 shows the recommended modules.
|
Model |
Description |
Power Module |
W0PSA1701 |
170W AC Power Module(Used In HI Series) |
ES5M0PSD1700 |
170W DC power module (Used In HI Series) |
|
Optical Transceivers |
OMXD30000 |
Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm,0.3km,LC) |
OSX010000 |
Optical Transceiver, SFP+, 10G, Single-mode Module(1310nm,10km,LC) |
|
SFP-10G-USR |
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm,0.1km,LC) |
|
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm,0.5km,LC) |
|
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP ,GE ,Single-mode Module(1310nm,10km,LC) |
|
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,40km,LC) |
|
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm,40km,LC) |
|
Copper Transceivers |
SFP-1000BaseT |
1000BASE-T (RJ45) SFP Electrical Module, Auto Negotiate,100m |
Card |
ES5D00X2SA00 |
2 10 Gig SFP+ interface card(used in S5700HI series) |
ES5D00X4SA00 |
4 10 Gig SFP+ interface card(used in S5700HI series) |
|
ES5D00G4SC00 |
4 Gig SFP interface card(used in S5700HI series) |
Compare with Similar Item
Table 3 shows the comparison of Huawei S5700-28C-HI, S5700-28C-HI-AC and S5700-28C-HI-24S.
Models |
S5700-28C-HI |
S5700-28C-HI-AC |
S5700-28C-HI-24S |
Fixed Ports |
24 x 10/100/1,000 Base-T |
24 x 10/100/1,000 Base-T |
24 x 100/1,000 Base-X
|
Extended Slots |
1 extended slot |
1 extended slots |
1 extended slots |
Power Supply |
Double hot-swappable AC/DC |
Double hot-swappable AC/DC |
Double hot-swappable AC |
Forwarding Performance |
96 Mpps |
96 Mpps |
96 Mpps |
Switching Capacity |
256 Gbit/s |
256 Gbit/s |
256 Gbit/s |
Power Consumption |
<76W |
<76W |
<80W |
Comparison between LI, SI, EI and HI
Huawei S5700 Series Enterprise Switches provides LI (Lite), SI (Standard), EI (Enhanced) and HI (Hyper) models for users. There are some differences among these four versions.
Click this PDF to know more.
Comparison of Huawei S5700-LI, SI, EI and HI Series Switches.pdf
Что бы получить больше информации
У вас есть какие-либо вопросы о Huawei S5700-28C-HI switch?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
Input voltage | AC: Rated voltage range: 100 V to 240 V AC, 50/60 Hz Maximum voltage range: 90 V to 264 V AC, 47/63 Hz DC: Rated voltage range: –48 V to –60 V, DC Maximum voltage range: –36 V to –72 V DC Note: PoE-support switches do not use DC power supplies. |
Multicast | IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) |
Security | User privilege management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, interface, and VLAN Port isolation, port security, and sticky MAC MFF Blackhole MAC address entries Limit on the number of learned MAC addresses 802.1x authentication and limit on the number of users on an interface AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC SSH v2.0 Hypertext Transfer Protocol Secure (HTTPS) CPU defense Blacklist and whitelist |
VLAN | 4K VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports 1:1 and N:1 VLAN Mapping SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) |
Ring protection | RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover SEP ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) STP, RSTP, and MSTP BPDU protection, root protection, and loop protection BPDU Tunnel |
MPLS features | MPLS L3VPN MPLS L2VPN(VPWS/VPLS) MPLS-TE MPLS QoS Notes: supported by S5710-EI, S5700-HI and S5710-HI |
Management and maintenance | Virtual cable test Port mirroring and RSPAN (remote port mirroring) Remote configuration and maintenance using Telnet SNMP v1/v2c/v3 RMON Web NMS HGMP System logs and alarms of different levels 802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN switches) NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series) |
MAC address table | IEEE 802.1d compliance MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses MAC address entries: S5700S-LI series: 8K, S5700-LI/S5700-SI series: 16K, S5700-EI series: 32K, S5720-EI series: 64K, S5700-HI series: S5700-HI: 32K, S5710-HI: 456K, S5720-HI: 128K |
IP routing | Static routing RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) |
Interoperability | Supports VBST (Compatible with PVST/PVST+/RPVST) Supports LNP (Similar to DTP) Supports VCMP (Similar to VTP) |
IPv6 features | Neighbor Discovery (ND) Path MTU (PMTU) IPv6 ping, IPv6 tracert, and IPv6 Telnet ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type MLD v1/v2 snooping 6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series) |
Operating environment | Operating temperature: 0 –50 Relative humidity: 10%–90% (non-condensing) |
Reliability | Ethernet OAM (IEEE 802.3ah and 802.1ag) ITU-Y.1731 DLDP LACP E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series) BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) |
QoS/ACL | Rate limiting on packets sent and received by an interface Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues on each port WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms WRED (supported by the S5710-EI and S5700-HI) Re-marking of the 802.1p priority and DSCP priority Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Rate limiting in each queue and traffic shaping on ports |
Access Security | DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security |