+7 (812) 309 34 73. Договоримся!
Huawei S6720-54C-EI-48S-AC switch is one of the Huawei S6720 series Switches. The S6720 series offers high-availability, scalable 10 Gbit/s server access for Internet Data Centers (IDCs) and large traditional data centers. It also provides optional configuration of 4 x 40 GE QSFP+ interface card gives the S6720-EI Series Switches unusual flexibility: use to provide access to high-bandwidth server-based applications, or as a core or aggregation switch in enterprise campus networks.
Quick Specs
Figure 1 shows the appearance of Huawei S6720-54C-EI-48S-AC switch.
Table 1 shows the Quick Specs.
Product Code |
S6720-54C-EI-48S-AC |
Ports |
48 x 10 GE SFP+, 2 x 40 GE QSFP+ ports |
Interface Slot |
1 |
Power Supply |
AC Power Supply |
Forwarding Performance |
1,080 Mpps |
Switching Capacity |
2.56 Tbit/s |
Stack |
Supported |
Stack Ports |
- Any 10GE SFP+ ports (a maximum of 16 physical ports) - Any 40GE QSFP+ ports (a maximum of 6 physical ports) |
Memory (RAM) |
2 GB |
Flash |
240 MB |
Dimensions (W x D x H) |
44.2 cm x 42 cm x 4.44 cm |
Weight (Kg) |
10.2 Kg |
Product Details
Figure 2 shows the front panel of Huawei S6720-54C-EI-48S-AC switch.
Note:
① |
48 × 10GE SFP+ ports |
④ |
ETH management port |
② |
2 × 40GE QSFP+ ports |
⑤ |
One console port |
③ |
One USB port |
Figure 3 shows the back panel of Huawei S6720-54C-EI-48S-AC switch with installed fan modules and power modules. These modules should be purchased separately.
Note:
① |
Ground screw |
④ |
Power module slot 2 |
② |
Rear card slot |
⑤ |
Power module slot 1 |
③ |
Fan slot |
The Accessories
Table 2 shows the recommended transceivers, card and power module.
Model |
Description |
|
GE-SFP Optical Transceiver |
||
SFP-1000BaseT |
Electrical Transceiver, SFP, GE, Electrical Interface Module(100m,RJ45) |
|
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm,0.55km,LC) |
|
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,10km,LC) |
|
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,40km,LC) |
|
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm,40km,LC) |
|
10GE SFP+ optical transceiver |
||
SFP-10G-USR |
10GBase-USR Optical Transceiver,SFP+,10G,Multi-mode Module(850nm,0.1km,LC) |
|
OMXD30000 |
Optical Transceiver,SFP+,10G,Multi-mode Module(850nm,0.3km,LC) |
|
OSX010000 |
Optical Transceiver,SFP+,10G,Single-mode Module(1310nm,10km,LC) |
|
40GE optical transceiver |
||
QSFP-40G-ER4 |
40GBase-ER4 Optical Transceiver,QSFP+,40G,Single-mode Module (1310nm,40km,LC) |
|
QSFP-40G-LR4 |
40GBase-LR4 Optical Transceiver,QSFP+,40GE,Single-mode Module(1310nm,10km,LC) |
|
Card |
||
ES5D21Q04Q01 |
Huawei 4 × 40 Gig QSFP+ interface card(used in S6720EI series) |
|
Power Module |
||
PAC-600WA-B |
600W AC Power Module(Back to Front,Power panel side exhaust) |
Compare to Similar Items
Table 3 shows the comparison of Huawei S6720-30C-EI-24S-AC, S6720-54C-EI-48S-AC and S6720S-26Q-EI-24S-AC.
Models |
S6720-30C-EI-24S-AC |
S6720-54C-EI-48S-AC |
S6720S-26Q-EI-24S-AC |
Switching Capacity |
2.56 Tbit/s |
2.56 Tbit/s |
2.56 Tbit/s |
Forwarding Performance |
720 Mpps |
1,080 Mpps |
480 Mpps |
Fixed Ports |
24 x 10 GE SFP+, 2 x 40 GE QSFP+ ports |
48 x 10 GE SFP+, 2 x 40 GE QSFP+ ports |
24 x 10 GE SFP+, 2 x 40 GE QSFP+ ports |
Extended Slot |
One extended slot for 4 x 40 GE QSFP+ interface card |
One extended slot for 4 x 40 GE QSFP+ interface card |
Not supported |
Power Supply |
AC Power Supply |
AC Power Supply |
AC Power Supply |
Get more information
Do you have any question about the Huawei S6720-54C-EI-48S-AC switch?
Contact us now via Live Chat or info@itg-spb.ru.
S6720-54C-EI-48S-AC Specifications |
|
Fixed Ports |
48 × 10 GE SFP+, 2 x 40 GE QSFP+ ports |
Extended Slot |
One extended slot for 4 x 40 GE QSFP+ interface card |
MAC Address Table |
288K MAC address entries |
VLAN |
4K VLANs |
IPv4 Routing |
Static routing, RIPv1, RIPv2, ECMP, and URPF |
IPv6 Routing |
Static route |
IPv6 Features |
Neighbor Discovery (ND) |
Multicast |
Static Layer 2 multicast MAC address |
QoS/ACL |
Rate limiting on packets sent and received by an interface |
MPLS |
MPLS, MPLS VLL, L3VPN |
VPLS |
Martini VPLS |
Reliability |
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
Security |
User privilege management and password protection |
Super Virtual Fabric (SVF) |
Working as the parent node to vertically virtualize downlink switches as one device for management, supports two-layer clients architecture |
Management and Maintenance |
iStack (using service ports as stack ports) |
Operating Environment |
Operating temperature: 0m to 1,800m: 0°C to 45°C; 1,800m to 5,000m: 1°C decrease for every 220m increase in altitude |
Input Voltage |
AC: |
Dimensions (W x D x H) |
442 mm x 420 mm x 44.4 mm |
Typical Power Consumption |
AC: |
Характеристики | |
Dimensions (W x D x H) | 442 mm x 420 mm x 44.4 mm |
Extended slot | One extended slot for 4 x 40 GE QSFP+ interface card |
Fixed ports | 48 × 10 GE SFP+, 2 x 40 GE QSFP+ ports |
Input voltage | AC:Rated voltage range: 100V to 240V, 50 Hz/60 HzMaximum voltage range: 90V to 264V, 50 Hz/60 Hz |
IPv4 routing | Static routing, RIPv1, RIPv2, ECMP, and URPFOSPF, IS-IS, and BGPVRRPPolicy-based routingRouting policy |
IPv6 features | Neighbor Discovery (ND)PMTUIPv6 ping, IPv6 tracert, and IPv6 Telnet6to4 tunnel, ISATAP tunnel, and manually configured tunnelACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol typeMLD v1/v2 snooping |
IPv6 routing | Static routeRIPngOSPFv3BGP4+ISISv6 |
MAC Address Table | 288K MAC address entriesMAC address learning and agingStatic, dynamic, and black hole MAC address entriesPacket filtering based on source MAC addresses |
Management and Maintenance | iStack (using service ports as stack ports)MAC Forced Forwarding (MFF)Virtual cable testEthernet OAM (IEEE 802.3ah and 802.1ag)Local port mirroring and Remote Switched Port Analyzer (RSPAN), allowing an observing port to forward packetsRemote configuration and maintenance using TelnetSNMP v1/v2c/v3RMONWeb NMSSystem logs and alarms of different levelsGVRPMUX VLAN |
MPLS | MPLS, MPLS VLL, L3VPN |
Multicast | Static Layer 2 multicast MAC addressMAC-based multicast forwardingIGMP snooping and IGMP fast leaveMulticast VLANMLD snoopingIGMP proxyControllable multicastPort-based multicast traffic statisticsIGMP v1/v2/v3PIM-SM, PIM-DM, and PIM-SSMMSDPMVPN |
Operating Environment | Operating temperature: 0m to 1,800m: 0°C to 45°C; 1,800m to 5,000m: 1°C decrease for every 220m increase in altitudeRelative humidity: 5% to 95% (non-condensing) |
QoS/ACL | Rate limiting on packets sent and received by an interfacePacket redirectionPort-based traffic policing and two-rate three-color CAREight queues on each portWRR, DRR, SP, WRR + SP, and DRR + SP queue scheduling algorithmsRe-marking of the 802.1p priority and DSCP priorityPacket filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, port number, protocol type, and VLAN IDRate limiting in each queue and traffic shaping on ports |
Reliability | STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)BPDU protection, root protection, and loop protectionRRPP ring topology and RRPP multi-instanceSmart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchoverSEPERPS (G.8032v2)BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIME-Trunk |
Security | User privilege management and password protectionDoS attack defense, ARP attack defense, and ICMP attack defenseBinding of the IP address, MAC address, interface, and VLANPort isolation, port security, and sticky MACBlackhole MAC address entriesLimit on the number of learned MAC addresses802.1x authentication and limit on the number of users on an interfaceAAA authentication, RADIUS authentication and TACACS authenticationSSH v2.0Hypertext Transfer Protocol Secure (HTTPS)CPU defenseBlacklist and whitelist |
Super Virtual Fabric (SVF) | Working as the parent node to vertically virtualize downlink switches as one device for management, supports two-layer clients architectureSupport as a client node to be managed by SVF parent |
Typical Power Consumption | AC:without subcard: 190Wwith subcard: 209W |
VLAN | 4K VLANsGuest VLAN and voice VLANVLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports1:1 and N:1 VLAN MappingQinQ and selective QinQ |
VPLS | Martini VPLS |