+7 (812) 309 34 73. Договоримся!
S5735S-S24T4S-A is the Huawei S5735-S switch with 24 × 10/100/1000Base-T ports, 4 × GE SFP ports, and 1 × 60W AC Power Supply. Huawei CloudEngine S5735S-S is a series of standard gigabit access switches that provide 24–48 flexible all-GE downlink ports and four fixed 10 GE uplink ports. They are designed for enterprise campus network access and aggregation, as well as data center access. Built on next-generation, high-performance hardware and with the Huawei Versatile Routing Platform (VRP), CloudEngine S5735-S switches boast advanced features, such as enhanced Layer 3 functionality, simplified O&M, flexible Ethernet networking, and mature IPv6 capabilities.
Quick Spec
Table 1 shows the quick spec.
Product Model |
S5735-S24T4S-A |
Fixed Ports |
24 × 10/100/1000Base-T ports, 4 × GE SFP ports |
PoE+ |
Not supported |
Supported Transceivers
Table 2 shows the recommended models.
Model |
Description |
OMXD30000 |
Huawei Optical Transceiver OMXD30000, SFP+, 10G, Multi-mode Module (850nm, 0.3km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 10km, LC) |
OMXD30009 |
Transceiver, QSFP+, 1310nm, 41.25Gbps, -7dBm, 2.3dBm, -11.5dBm, LC, SMF, 10 |
ESFP-GE-SX-MM850
|
Optical Transceiver, eSFP, GE, Multi-mode Module (850nm,0.5km, LC) |
Get More Information
Do you have any question about the S5735S-S24T4S-A?
Contact us now via Live Chat or info@itg-spb.ru.
S5735S-S24T4S-A Specification |
|
Memory (RAM) |
1 GB |
Flash |
512 MB in total. To view the available flash memory size, run the display version command. |
Mean time between failures (MTBF) |
69.42 years |
Mean time to repair (MTTR) |
1.73 hours |
Availability |
> 0.99999 |
Service port surge protection |
Common mode: ±7 kV |
Power supply surge protection |
Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode Using DC power modules: ±2 kV in differential mode, ±4 kV in common mode |
Dimensions (H x W x D) |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 444.2 mm (1.72 in. x 17.4 in. x 17.49 in.) |
Stack ports |
Any 10/100/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions) |
RTC |
Supported |
RPS |
Not supported |
PoE |
Not supported |
Rated voltage range |
AC input: 100 V AC to 240 V AC, 50/60 Hz High-Voltage DC input: 240 V DC DC input: -48 V DC to -60 V DC |
Maximum voltage range |
AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz High-Voltage DC input: 190 V DC to 290 V DC DC input: -38.4 V DC to -72 V DC |
Maximum power consumption (100% throughput, full speed of fans) |
44 W |
Typical power consumption (30% of traffic load) Tested according to ATIS standard EEE enabled No PoE power consumption |
29 W |
Operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
Short-term operating temperature |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) NOTE: When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year. The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year. The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year. The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
Noise under normal temperature (27°C, sound power) |
< 58.9 dB(A) |
Relative humidity |
5% to 95%, noncondensing |
Operating altitude |
0-5000 m (0-16404 ft.) |
Certification |
EMC certification Safety certification Manufacturing certification |
Характеристики | |
Availability | > 0.99999 |
Certification | EMC certificationSafety certificationManufacturing certification |
Dimensions (H x W x D) | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 444.2 mm (1.72 in. x 17.4 in. x 17.49 in.) |
Flash | 512 MB in total. To view the available flash memory size, run the display version command. |
Maximum power consumption (100% throughput, full speed of fans) | 44 W |
Maximum voltage range | AC input: 90 V AC to 264 V AC, 47 Hz to 63 HzHigh-Voltage DC input: 190 V DC to 290 V DCDC input: -38.4 V DC to -72 V DC |
Mean time between failures (MTBF) | 69.42 years |
Mean time to repair (MTTR) | 1.73 hours |
Memory (RAM) | 1 GB |
Noise under normal temperature (27°C, sound power) | < 58.9 dB(A) |
Operating altitude | 0-5000 m (0-16404 ft.) |
Operating Temperature | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)NOTE:When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).The switch cannot be started when the ambient temperature is lower than 0°C (32°F). |
PoE | Not supported |
Power supply surge protection | Using AC power modules: ±6 kV in differential mode, ±6 kV in common modeUsing DC power modules: ±2 kV in differential mode, ±4 kV in common mode |
Rated voltage range | AC input: 100 V AC to 240 V AC, 50/60 HzHigh-Voltage DC input: 240 V DCDC input: -48 V DC to -60 V DC |
Relative humidity | 5% to 95%, noncondensing |
RPS | Not supported |
RTC | Supported |
Service port surge protection | Common mode: ±7 kV |
Short-term operating temperature | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)NOTE:When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Stack ports | Any 10/100/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions) |
Storage temperature | -40°C to +70°C (-40°F to +158°F) |
Typical power consumption (30% of traffic load)Tested according | 29 W |
Теги: S5735S-S24T4S-A Huawei