+7 (812) 309 34 73. Договоримся!
Built on next-generation, high-performance hardware and powered by Huawei’s Versatile Routing Platform (VRP), CloudEngine S5735-L switches feature flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks.
Quick Spec
Table 1 shows the quick spec.
Product Model |
S5735-L48T4X-A1 |
Memory |
512 MB |
Flash memory |
512 MB |
Typical power consumption [W] |
51.9 W |
Typical heat dissipation [BTU/hour] |
177.09 BTU/hour |
Supported Transceivers
Table 2 shows the recommended models.
Model |
Description |
OMXD30000 |
Huawei Optical Transceiver OMXD30000, SFP+, 10G, Multi-mode Module (850nm, 0.3km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 10km, LC) |
OMXD30009 |
Transceiver, QSFP+, 1310nm, 41.25Gbps, -7dBm, 2.3dBm, -11.5dBm, LC, SMF, 10 |
ESFP-GE-SX-MM850
|
Optical Transceiver, eSFP, GE, Multi-mode Module (850nm,0.5km, LC) |
Compare to Similar Items
Table 3 shows the comparison.
Product Model |
S5735S-L12T4S-A S5735S-L12P4S-A |
S5735S-L24T4S-A S5735S-L24P4S-A |
S5735S-L24T4X-A S5735S-L24P4X-A |
S5735S-L48T4S-A |
S5735S-L48T4X-A S5735S-L48P4X-A |
S5735S-L32ST4X-A |
Forwarding Performance |
24 Mpps |
42 Mpps |
96 Mpps |
78 Mpps |
132 Mpps |
108 Mpps |
Switching Capacity2 |
32 Gbit/s/336 Gbit/s |
56 Gbit/s/336 Gbit/s |
128 Gbit/s/336 Gbit/s |
104 Gbit/s/432 Gbit/s |
176 Gbit/s/432 Gbit/s |
144 Gbit/s/432 Gbit/s |
Fixed Ports |
12 x 10/100/1000Base-T ports, 4 x GE SFP ports |
24 x 10/100/1000Base-T ports, 4 x GE SFP ports |
24 x 10/100/1000Base-T ports, 4 x 10 GE SFP+ ports |
48 x 10/100/1000BASE-T ports, 4 x GE SFP ports |
48 x 10/100/1000BASE-T ports, 4 x 10 GE SFP+ ports |
24 x GE SFP ports, 8 x 10/100/1000BASE-T ports, 4 x 10 GE SFP+ ports |
PoE+ |
CloudEngine S5735S-L12P4S-A: Supported |
Get More Information
Do you have any question about the S5735-L48T4X-A1?
Contact us now via Live Chat or info@itg-spb.ru.
S5735-L48T4X-A1 Specification |
|
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] |
90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Chassis height [U] |
1 U |
Typical power consumption [W] |
43.2 W |
Typical heat dissipation [BTU/hour] |
147.4 BTU/hour |
Maximum power consumption [W] |
51.9 W |
Maximum heat dissipation [BTU/hour] |
177.09 BTU/hour |
MTBF [year] |
53.67 year |
MTTR [hour] |
2 hour |
Availability |
>0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] |
48 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] |
36.2 dB(A) |
Number of card slots |
0 |
Number of power slots |
0 |
Number of fans modules |
1 |
Redundant power supply |
Not supported |
Long-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Short-term operating temperature [°C(°F)] |
-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The operating temperature ranges from -5°C to +45°C (23°F to 113°F) when optical modules with transmission distances greater than or equal to 70 km are used. The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:
The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
Storage temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
AC built-in |
Rated input voltage [V] |
AC input: 100 V AC to 240 V AC, 50/60 Hz |
Input voltage range [V] |
AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum input current [A] |
2 A |
Memory |
512 MB |
Flash memory |
512 MB |
Console port |
RJ45 |
Eth Management port |
Not supported |
USB |
Supported |
RTC |
Not supported |
RPS input |
Not supported |
Service port surge protection [kV] |
Common mode: ±7 kV |
Power supply surge protection [kV] |
±6 kV in differential mode, ±6 kV in common mode |
Types of fans |
Built-in |
Heat dissipation mode |
Heat dissipation with fan, intelligent fan speed adjustment |
Airflow direction |
Air intake from left and front, air exhaustion from right |
PoE |
Not supported |
Certification |
EMC certification Safety certification Manufacturing certification |
Характеристики | |
Airflow direction | Air intake from left and front, air exhaustion from right |
Availability | >0.99999 |
Certification | EMC certificationSafety certificationManufacturing certification |
Chassis height [U] | 1 U |
Console Port | RJ45 |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.7 in.)Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Eth Management port | Not supported |
Flash Memory | 512 MB |
Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
Input voltage range [V] | AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz |
Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Long-term operating relative humidity [RH] | 5% to 95%, noncondensing |
Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
Maximum heat dissipation [BTU/hour] | 177.09 BTU/hour |
Maximum input current [A] | 2 A |
Maximum power consumption [W] | 51.9 W |
Memory | 512 MB |
MTBF [year] | 53.67 year |
MTTR [hour] | 2 hour |
Noise at normal temperature (acoustic power) [dB(A)] | 48 dB(A) |
Noise at normal temperature (acoustic pressure) [dB(A)] | 36.2 dB(A) |
Number of card slots | 0 |
Number of fans modules | 1 |
Number of power slots | 0 |
PoE | Not supported |
Power Supply Mode | AC built-in |
Power supply surge protection [kV] | ±6 kV in differential mode, ±6 kV in common mode |
Rated input voltage [V] | AC input: 100 V AC to 240 V AC, 50/60 Hz |
Redundant power supply | Not supported |
Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).The operating temperature ranges from -5°C to +45°C (23°F to 113°F) when optical modules with transmission distances greater than or equal to 70 km are used.The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year.The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year.The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year.The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. |
RPS input | Not supported |
RTC | Not supported |
Service port surge protection [kV] | Common mode: ±7 kV |
Short-term operating temperature [°C(°F)] | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) |
Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Types of fans | Built-in |
Typical heat dissipation [BTU/hour] | 147.4 BTU/hour |
Typical power consumption [W] | 43.2 W |
USB | Supported |
Теги: S5735-L48T4X-A1 Huawei