Характеристики
4094 VLANsGuest VLAN and voice VLANGVRPMUX VLANVLAN assignment b Ethernet loop protection
A two-layer client architecture is supported.IGMP snooping can b iPCA
Chassis Height 1 U
Chassis weight (including packaging) 8.55 kg
Dimensions (W x D x H) 442 mm x 420 mm x 43.6 mm
Directly coloring service packets to collect real-time statistic TWAMP
Fixed port 48 x 10/100/1000Base-T ports, 4 x 10GE SFP+ ports
Heat dissipation Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans
Hierarchical user management and password protectionDoS attack d Reliability
IEEE 802.1d standards compliance32K MAC address entriesMAC addre VLAN
IGMP v1/v2/v3 snooping and IGMP fast leaveMulticast forwarding i QoS/ACL
iStack, with up to 9 member switches in a stackSNMP v1/v2c/v3RMO *CloudEngine S5731-S series switches require the VXLAN license or N1 advanced software package to support the VXLAN feature.
LACPE-trunkEthernet OAM (IEEE 802.3ah and IEEE 802.1ag)ITU-Y.173 VXLAN*
Maximum power consumption 124 W
Maximum voltage range • AC input (150 W AC ): 90 V AC to 264 V AC, 47 Hz to 63 Hz• AC input (600 W AC ): 90 V AC to 290 V AC, 45 Hz to 65 Hz• High-voltage DC input (600 W AC): 190 V DC to 290 V DC (meeting 240 V high-voltage DC certification)• DC input (1000 W DC): -38.4 V DC to -72V DC
Noise • Under normal temperature (sound power): 57.5dB (A)• Under high temperature (sound power): 70.9dB (A)• Under normal temperature (sound pressure): 47.5dB (A)
Operating Temperature • 0-1800 m altitude: -5°C to +45°C• 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m.
Power supply type • 150 W AC (pluggable)• 600 W AC (pluggable)• 1000 W DC (pluggable)
Rate limiting in the inbound and outbound directions of a portPa Security
Rated voltage range • AC input (150 W AC ): 100 V AC to 240 V AC, 50/60 Hz• AC input (600 W AC ): 100 V AC to 240 V AC, 50/60 Hz• DC input (1000 W DC): -48 VDC to -60 V DC
Relative humidity 5% to 95% (non-condensing)
RRPP ring topology and RRPP multi-instanceSmart Link tree topolo IP routing
Service Features MAC address table
Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BG Interoperability
Storage temperature -40℃ to +70℃
Surge protection specification (power port) • AC power port: ±6 kV in differential mode, ±6 kV in common mode• DC power port: ±2 kV in differential mode, ±4 kV in common mode
Surge protection specification (service port) Common mode: ±6 kV
Two-way IP link performance measurementMeasurement on two-way pa Management and maintenance
Up to 8K ND entriesPMTUIPv6 Ping, IPv6 Tracert, and IPv6 TelnetA Multicast
VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and R IPv6 features
VXLAN L2 and L3 gatewaysCentralized and distributed gatewayBGP-E Super Virtual Fabric (SVF)