CE6810-24S2Q-LI-B is one of the Huawei CE6810-24S2Q-LI Series Switches. The Huawei CE6810-24S2Q-LI Series Switches provide high-throughput, low-latency performance for data centers and high-end campus networks. 2 40 GE uplink ports enable exceptional performance when bridging with core switches using a Transparent Interconnection of Lots of Links (TRILL) network. Combine CE6800 and CE12800 switches to implement a non-blocking network platform. Huawei CloudEngine 6800 (CE6800) series switches are next-generation 10G Ethernet switches designed for data centers and high-end campus networks. Using the Huawei VRP8 software platform, CE6800 switches provide extensive data center service features and high stacking capability. In addition, the airflow direction (front-to-back or back-to-front) can be changed. CE6800 switches can work with CE12800 switches to build an elastic, virtualized, high-quality fabric that meets the requirements of cloud-computing data centers.o help enterprises and carriers build a scalable data center network platform in the cloud computing era.
Quick Specs
Figure 1 shows the appearance of CE6810-24S2Q-LI-B.
Table 1 shows the Quick Specs.
Product Code |
CE6810-24S2Q-LI-B |
Part Number |
02350GUD |
Software Version |
V100R005C10 and later |
Fixed GE interfaces |
None |
Fixed 10GE interfaces |
24*10GE SFP+ |
Fixed 40GE interfaces |
2*40GE QSFP+ A 40GE interface can be split into four 10GE interfaces. |
Fixed 100GE interfaces |
None |
Switching Capacity |
640 Gbit/s |
Forwarding Rate |
480 Mpps |
Rated voltage range(with power module) |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum power consumption |
171W |
Airflow Design |
Front-to-back or back-to-front |
Dimensions (W x D x H) |
442 mm x 600 mm x 43.6 mm |
Weight (fully loaded) |
10.1 kg (22.3 lb) |
Product Details
Figure 2 shows the rear (port side) panel of CE6810-24S2Q-LI-B.
Note:
① |
Twenty-four 10GE SFP+ Ethernet optical ports |
② |
Two 40GE QSFP+ Ethernet optical ports |
Figure 3 shows the front (power supply side) panel of CE6810-24S2Q-LI-B.
Note:
① |
Power supply slot 1 |
② |
Fan slot 1 |
③ |
Console port |
④ |
Bar code label |
⑤ |
Fan slot 2 |
⑥ |
Power supply slot 2 |
⑦ |
USB port |
⑧ |
ETH management port |
The Modules
Table 2 shows the recommended elements for the CE6810-24S2Q-LI-B.
Model |
Description |
GE-SFP Optical Transceiver |
|
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC) |
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC) |
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC) |
10G-SFP+ Optical Transceiver |
|
SFP-10G-USR |
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC) |
OMXD30000 |
Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC) |
40GE QSFP+ optical transceiver |
|
QSFP-40G-iSR4
|
40GBase-iSR4 Optical Transceiver,QSFP+,40G,Multi-mode (850nm,0.15km,MPO)(Connect to four SFP+ Optical Transceiver) |
QSFP-40G-LR4
|
40GBase-LR4 Optical Transceiver,QSFP+,40GE,Single-mode Module(1310nm,10km,LC) |
GE Copper Transceiver |
|
SFP-1000BaseT |
Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45) |
FAN-40EA |
|
FAN-40EA-F
|
Fan box(EA,Front to Back,FAN panel side intake) |
FAN-40EA-B
|
Fan box(EA,Back to Front,FAN panel side exhaust) |
Compare to Similar Items
Table 3 shows the comparison of CE6810-24S2Q-LI-B, CE6810-32T16S4Q-LI-B and CE6810-48S4Q-EI.
Product Code |
CE6810-24S2Q-LI-B |
CE6810-32T16S4Q-LI-B |
CE6810-48S4Q-EI |
Software Version |
V100R005C10 and later |
V100R005C10 and later |
V100R003C00 and later |
Fixed 10GE interfaces |
24*10GE SFP+ |
32*10GBASE-T 16*10GE SFP+ |
48*10GE SFP+ |
Fixed 40GE interfaces |
2*40GE QSFP+ A 40GE interface can be split into four 10GE interfaces. |
4*40GE QSFP+ A 40GE interface can be split into four 10GE interfaces |
4*40GE QSFP+ A 40GE interface can be split into four 10GE interfaces. |
Fixed 100GE interfaces |
None |
None |
None |
Switching Capacity |
640 Gbit/s |
1.28 Tbit/s |
1.28 Tbit/s |
Forwarding Rate |
480 Mpps |
960 Mpps |
960 Mpps |
Maximum power consumption |
171W |
288W |
238W |
Get more information
Do you have any question about the CE6810-24S2Q-LI-B?
Contact us now via Live Chat or info@itg-spb.ru.
CE6810-24S2Q-LI-B Specification |
|
10G Base-T Ports |
0 |
SFP+ Ports |
24 |
QSFP+ Ports |
2 |
Switching Capacity |
640 Gbit/s |
Forwarding Rate |
480 Mpps |
Airflow Design |
Front-to-back or back-to-front |
Device Virtualization |
iStack |
Super Virtual Fabric (SVF) |
|
Network Virtualization |
M-LAG |
VM Awareness |
Agile Controller |
Network Convergence |
FCoE |
DCBX, PFC, and ETS |
|
Programmability |
OpenFlow |
OPS |
|
Linux container for open source and customization programming |
|
Traffic Analysis |
NetStream |
sFlow |
|
VLAN |
Adding access, trunk, and hybrid interfaces to VLANs |
Default VLAN |
|
QinQ |
|
MUX VLAN |
|
GVRP |
|
ACL |
Ingress: 1,250 |
MAC Address Table |
Maximum: 128k |
Dynamic learning and aging of MAC addresses |
|
Static, dynamic, and blackhole MAC address entries |
|
Packet filtering based on source MAC addresses |
|
MAC address limiting based on ports and VLANs |
|
ARP (maximum) |
1.5k |
IPv4 FIB (maximum) |
1.5k |
IP Routing |
IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS |
IPv6 FIB (maximum) |
/ |
Multicast FIB (maximum) |
/ |
Multicast |
IGMP snooping |
Reliability |
LACP |
STP, RSTP, VBST, MSTP |
|
BPDU protection, root protection, and loop protection |
|
Smart Link and multi-instance |
|
DLDP |
|
ERPS (G.8032) |
|
VRRP, VRRP load balancing, and BFD for VRRP |
|
QoS |
Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority |
Actions of ACL, CAR, re-marking, and scheduling |
|
Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, and PQ + DRR |
|
Congestion avoidance mechanisms, including WRED and tail drop |
|
Traffic shaping |
|
Configuration and Maintenance |
Console, Telnet, and SSH terminals |
Network management protocols, such as SNMPv1/v2c/v3 |
|
File upload and download through FTP and TFTP |
|
BootROM upgrade and remote upgrade |
|
802.3az Energy Efficient Ethernet (EEE) |
|
Hot patches |
|
User operation logs |
|
ZTP |
|
Security and Management |
802.1x authentication |
Command line authority control based on user levels, preventing unauthorized users from using commands |
|
DoS, ARP, and ICMP attack defenses |
|
Port isolation, port security, and sticky MAC |
|
Binding of the IP address, MAC address, interface number, and VLAN ID |
|
Authentication methods, including AAA, RADIUS, and HWTACACS |
|
Remote Network Monitoring (RMON) |
|
Dimensions (W x D x H) |
442 mm x 600 mm x 43.6 mm |
Weight (fully loaded) |
10.1 kg (22.3 lb) |
Environmental Parameters |
Operating temperature: 0°C to 40°C (32°F to 104°F) (0m to 1,800m) |
Operating Voltage |
AC: 90V to 290V |
Max. Power Consumption |
171W |
Характеристики | |
/ | Multicast |
1.5k | IP Routing |
10G Base-T Ports | 0 |
802.3az Energy Efficient Ethernet (EEE) | Hot patches |
Adding access, trunk, and hybrid interfaces to VLANs | Default VLAN |
Agile Controller | Network Convergence |
Airflow Design | Front-to-back or back-to-front |
Authentication methods, including AAA, RADIUS, and HWTACACS | Remote Network Monitoring (RMON) |
BPDU protection, root protection, and loop protection | Smart Link and multi-instance |
Command line authority control based on user levels, preventing | DoS, ARP, and ICMP attack defenses |
Console, Telnet, and SSH terminals | Network management protocols, such as SNMPv1/v2c/v3 |
Device Virtualization | iStack |
Dimensions (W x D x H) | 442 mm x 600 mm x 43.6 mm |
DLDP | ERPS (G.8032) |
Environmental Parameters | Operating temperature: 0°C to 40°C (32°F to 104°F) (0m to 1,800m) Storage temperature: -40°C to 70°C (-40°F to 158°F) Relative humidity: 5% RH to 95% RH, non-condensing |
FCoE | DCBX, PFC, and ETS |
File upload and download through FTP and TFTP | BootROM upgrade and remote upgrade |
Forwarding Rate | 480 Mpps |
GVRP | ACL |
IGMP Snooping | Reliability |
Ingress: 1,250 Egress: 500 | MAC Address Table |
IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS | IPv6 FIB (maximum) |
LACP | STP, RSTP, VBST, MSTP |
M-LAG | VM Awareness |
MAC address limiting based on ports and VLANs | ARP (maximum) |
Max. Power Consumption | 171W |
maximum: 128k | Dynamic learning and aging of MAC addresses |
Operating Voltage | AC: 90V to 290V DC: -38.4V to -72V |
OPS | Linux container for open source and customization programming |
Port isolation, port security, and sticky MAC | Binding of the IP address, MAC address, interface number, and VLAN ID |
Programmability | OpenFlow |
QinQ | MUX VLAN |
QSFP+ Ports | 2 |
Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, a | Congestion avoidance mechanisms, including WRED and tail drop |
Security and Management | 802.1x authentication |
sFlow | VLAN |
SFP+ Ports | 24 |
Static, dynamic, and blackhole MAC address entries | Packet filtering based on source MAC addresses |
Super Virtual Fabric (SVF) | Network Virtualization |
Switching capacity | 640 Gbit/s |
Traffic Analysis | NetStream |
Traffic classification based on Layer 2 headers, Layer 3 protoco | Actions of ACL, CAR, re-marking, and scheduling |
Traffic shaping | Configuration and Maintenance |
User operation logs | ZTP |
VRRP, VRRP load balancing, and BFD for VRRP | QoS |
Weight (fully loaded) | 10.1 kg (22.3 lb) |
Теги: CE6810-24S2Q-LI-B Huawei