+7 (812) 309 34 73. Договоримся!
Huawei CE5855-24T4S2Q-EI-F provides 24 * GE line-speed ports plus 4 * 10 GE and 2 * 40G upstream ports for stacking up to 16 switches. 10 GE and 40G ports enable creation of a non-blocking stack that can extend across geographical distances between data centers. Using the Huawei VRP8 software platform, CE5800 switches support Transparent Interconnection of Lots of Links (TRILL) and have a high stacking capability (up to 16-member switches in a stack system). In addition, the airflow direction (front-to-back or back-to-front) can be changed. CE5800 switches can work with CE12800 switches to build an elastic, virtualized, high-quality fabric that meets the requirements of cloud-computing data centers. CE5800 switches provide high-density GE access to help enterprises build a scalable data center network platform for cloud computing. They can also be used as aggregation or access switches for enterprise campus networks.
Quick Specs
Figure 1 shows the appearance of CE5855-24T4S2Q-EI-F.
Table 1 shows the Quick Specs.
Product Code |
CE5855-24T4S2Q-EI-F |
Software Version |
V100R005C10 and later |
Base-T Ports |
24 |
SFP+ Ports |
4 |
QSFP+ Ports |
2 |
Switching Capacity |
288 Gbit/s |
Forwarding Rate |
215 Mpps |
Power module type |
Pluggable AC or DC power module, 1+1 backup supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz -48 V DC to -60 V DC |
Maximum power consumption |
75W |
Airflow |
Front-to-back or back-to-front, depending on the fan modules and power modules used in the chassis |
Dimensions (W x D x H) |
442 mm x 420 mm x 43.6 mm |
Weight (fully loaded) |
8.1 kg (17.8 lb) |
Product Details
Figure 2 shows the CE5855-24T4S2Q-EI-F rear view (port side).
Note:
① |
Twenty-four 10/100/1000BASE-T Ethernet electrical ports |
② |
Four 10GE SFP+ Ethernet optical ports |
③ |
Two 40GE QSFP+ Ethernet optical ports |
Figure 3 shows the CE5855-24T4S2Q-EI-F front view (power supply side).
Note:
① |
Power supply slot 1 |
② |
Fan slot 1 |
③ |
Console port |
④ |
Barcode label |
⑤ |
Fan slot 2 |
⑥ |
Power supply slot 2 |
⑦ |
USB port |
⑧ |
ETH management port (RJ45) |
The Modules
Table 2 shows the recommended elements for the CE5855-24T4S2Q-EI-F.
Model |
Description |
GE-SFP Optical Transceiver |
|
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC) |
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC) |
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC) |
10G-SFP+ Optical Transceiver |
|
SFP-10G-USR |
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC) |
OMXD30000 |
Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC) |
GE Copper Transceiver |
|
SFP-1000BaseT |
Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45) |
FAN-040A |
|
FAN-040A-F |
Huawei Fan box(F,FAN panel side intake) FAN-040A-F |
FAN-040A-B |
Huawei Fan box(B,FAN panel side exhaust) FAN-040A-B |
Compare to Similar Items
Table 3 shows the comparison of CE5855-24T4S2Q-EI-F and CE5855-48T4S2Q-EI-B.
Product Code |
CE5855-24T4S2Q-EI-F |
CE5855-48T4S2Q-EI-B |
Software Version |
V100R005C10 and later |
V100R005C10 and later |
Base-T Ports |
24 |
48 |
SFP+ Ports |
4 |
4 |
QSFP+ Ports |
2 |
2 |
Switching Capacity |
288 Gbit/s |
336 Gbit/s |
Forwarding Rate |
215 Mpps |
252 Mpps |
Maximum power consumption |
75W |
103W |
Get more information
Do you have any question about the CE5855-24T4S2Q-EI-F?
Contact us now via Live Chat or info@itg-spb.ru.
CE5855-24T4S2Q-EI-F Specifications |
|
Base-T Ports |
24 |
SFP+ Ports |
4 |
QSFP+ Ports |
2 |
Switching Capacity |
288 Gbit/s |
Forwarding Rates |
215 Mpps |
Airflow Design |
Front-to-back or back-to-front |
Device Virtualization |
iStack |
Super Virtual Fabric (SVF) |
|
Network Virtualization |
M-LAG |
TRILL (CE5855 & CE5850) |
|
Programmability |
Open Programmability System (OPS) |
Traffic Analysis |
NetStream |
sFlow |
|
VLAN |
Adding access, trunk, and hybrid interfaces to VLANs |
Default VLAN |
|
QinQ |
|
MUX VLAN |
|
GVRP |
|
ACL |
ingress: 4.5k |
MAC Address Table |
maximum: 64k |
Dynamic learning and aging of MAC addresses |
|
Static, dynamic, and black hole MAC address entries |
|
Packet filtering based on source MAC addresses |
|
MAC address limiting based on ports and VLANs |
|
ARP (maximum) |
54k |
ND (Maximum) |
16k |
IPv4 FIB (maximum) |
32k |
IP Routing |
IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS |
IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+ |
|
IPv6 FIB (maximum) |
16k |
IPv6 |
IPv6 Neighbor Discovery (ND) |
Path MTU Discovery (PMTU) |
|
TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6 |
|
Multicast FIB (maximum) |
2k |
Multicast |
IGMP, PIM-SM, PIM-DM, MSDP, and MBGP |
IGMP snooping |
|
Fast leave of multicast member interfaces |
|
Multicast traffic suppression |
|
Multicast VLAN |
|
Reliability |
LACP |
STP, RSTP, VBST, MSTP |
|
BPDU protection, root protection, and loop protection |
|
Smart Link and multi-instance |
|
DLDP |
|
ERPS (G.8032) |
|
VRRP, VRRP load balancing, and BFD for VRRP |
|
BFD for BGP/IS-IS/OSPF/Static route |
|
QoS |
Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority |
Actions of ACL, CAR, re-marking, and scheduling |
|
Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, and PQ + DRR |
|
Congestion avoidance mechanisms, including WRED and tail drop |
|
Traffic shaping |
|
Configuration and Maintenance |
Console, Telnet, and SSH terminals |
Network management protocols, such as SNMP v1/v2c/v3 |
|
File upload and download through FTP and TFTP |
|
BootROM upgrade and remote upgrade |
|
802.3az Energy Efficient Ethernet (EEE) |
|
Hot patches |
|
User operation logs |
|
Zero-Touch Provisioning (ZTP) |
|
Security and Management |
802.1x authentication |
Command line authority control based on user levels, preventing unauthorized users from using commands |
|
DoS, ARP, and ICMP attack defenses |
|
Port isolation, port security, and sticky MAC |
|
Binding of the IP address, MAC address, interface number, and VLAN ID |
|
Authentication methods, including AAA, RADIUS, and HWTACACS |
|
Remote Network Monitoring (RMON) |
|
Dimensions (W x D x H) |
442 mm x 420 mm x 43.6 mm |
Weight (fully loaded) |
8.1 kg (17.8 lb) |
Environmental Parameters |
Operating temperature: 0°C to 40°C (32°F to 104°F) (0m to 1,800m) |
Storage temperature: -40°C to 70°C (-40°F to 158°F) |
|
Relative humidity: 5% to 95%, non-condensing |
|
Operating Voltage |
AC: 90V to 264V |
DC: -38.4V to -72V |
|
Maximum Power Consumption |
75W |
Характеристики | |
16K | IPv4 FIB (maximum) |
32k | IP Routing |
54k | ND (Maximum) |
802.3az Energy Efficient Ethernet (EEE) | Hot patches |
Adding access, trunk, and hybrid interfaces to VLANs | Default VLAN |
Airflow Design | Front-to-back or back-to-front |
Authentication methods, including AAA, RADIUS, and HWTACACS | Remote Network Monitoring (RMON) |
Base-T Ports | 24 |
BFD for BGP/IS-IS/OSPF/Static route | QoS |
Command line authority control based on user levels, preventing | DoS, ARP, and ICMP attack defenses |
Console, Telnet, and SSH terminals | Network management protocols, such as SNMP v1/v2c/v3 |
DC: -38.4V to -72V | Maximum Power Consumption |
Device Virtualization | iStack |
Dimensions (W x D x H) | 442 mm x 420 mm x 43.6 mm |
Environmental Parameters | Operating temperature: 0°C to 40°C (32°F to 104°F) (0m to 1,800m) |
ERPS (G.8032) | VRRP, VRRP load balancing, and BFD for VRRP |
File upload and download through FTP and TFTP | BootROM upgrade and remote upgrade |
Forwarding Rates | 215 Mpps |
GVRP | ACL |
IGMP Snooping | Fast leave of multicast member interfaces |
ingress: 4.5k egress: 1k | MAC Address Table |
IPv4 routing protocols, such as RIP, OSPF, BGP, and IS-IS | IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+ |
IPv6 | IPv6 Neighbor Discovery (ND) |
IPv6 FIB (maximum) | 16k |
M-LAG | TRILL (CE5855 & CE5850) |
MAC address limiting based on ports and VLANs | ARP (maximum) |
maximum: 64k | Dynamic learning and aging of MAC addresses |
Multicast | IGMP, PIM-SM, PIM-DM, MSDP, and MBGP |
Multicast FIB (maximum) | 2k |
Multicast traffic suppression | Multicast VLAN |
Operating Voltage | AC: 90V to 264V |
Path MTU Discovery (PMTU) | TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6 |
Port isolation, port security, and sticky MAC | Binding of the IP address, MAC address, interface number, and VLAN ID |
Programmability | Open Programmability System (OPS) |
QinQ | MUX VLAN |
QSFP+ Ports | 2 |
Queue scheduling algorithms, including PQ, WRR, DRR, PQ + WRR, a | Congestion avoidance mechanisms, including WRED and tail drop |
Reliability | LACP |
Security and Management | 802.1x authentication |
sFlow | VLAN |
SFP+ Ports | 4 |
Smart Link and multi-instance | DLDP |
Static, dynamic, and black hole MAC address entries | Packet filtering based on source MAC addresses |
Storage temperature: -40°C to 70°C (-40°F to 158°F) | Relative humidity: 5% to 95%, non-condensing |
STP, RSTP, VBST, MSTP | BPDU protection, root protection, and loop protection |
Super Virtual Fabric (SVF) | Network Virtualization |
Switching capacity | 288 Gbit/s |
Traffic Analysis | NetStream |
Traffic classification based on Layer 2 headers, Layer 3 protoco | Actions of ACL, CAR, re-marking, and scheduling |
Traffic shaping | Configuration and Maintenance |
User operation logs | Zero-Touch Provisioning (ZTP) |
Weight (fully loaded) | 8.1 kg (17.8 lb) |