Характеристики
Airflow direction Air flows in from the left side and front panel, and exhausts from the right side.
Availability >0.99999
Certification EMC certificationSafety certificationManufacturing certification
Chassis height [U] 1 U
Console Port RJ45
Dimensions with packaging (H x W x D) [mm(in.)] 90 mm × 555 mm × 345 mm (3.54 in. x 21.85 in. x 13.58 in.)
Dimensions without packaging (H x W x D) [mm(in.)] Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 228.0 mm (1.72 in. x 17.4 in. x 9.0 in.)
Eth Management port RJ45
Flash Memory 1 GB in total. To view the available flash memory size, run the display version command.
Heat dissipation mode Heat dissipation with fan, intelligent fan speed adjustment
Input voltage range [V] AC input: 90 V AC to 290 V AC, 45 Hz to 65 HzHigh-Voltage DC input: 190 V DC to 290 V DC
Item Specification
Long-term operating altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Long-term operating relative humidity [RH] 5% to 95%, noncondensing
Long-term operating temperature [°C(°F)] -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
Maximum heat dissipation [BTU/hour] 378.74 BTU/hour
Maximum input current [A] 6.0 A
Maximum power consumption [W] 111 W
Memory 2 GB
MTBF [year] 41.97 year
MTTR [hour] 2 hour
Noise at normal temperature (acoustic power) [dB(A)] 56.8 dB(A)
Noise at normal temperature (acoustic pressure) [dB(A)] 44.8 dB(A)
Number of card slots 0
Number of fans modules 3
Number of power slots 0
PoE Not supported
Power Supply Mode AC built-in
Power supply surge protection [kV] ±6 kV in differential mode, ±6 kV in common mode
Rated input voltage [V] AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC, 50/60 HzHigh-Voltage DC input: 240 V DC
Redundant power supply Not supported
Restriction on the operating temperature variation rate [°C(°F)] When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.
RPS input Not supported
RTC Supported
Service port surge protection [kV] -
Short-term operating temperature [°C(°F)] -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
Storage altitude [m(ft.)] 0-5000 m (0-16404 ft.)
Storage temperature [°C(°F)] -40°C to +70°C (-40°F to +158°F)
Types of fans Built-in
Typical heat dissipation [BTU/hour] 296.85 BTU/hour
Typical power consumption [W] 87 W
USB Not supported