Характеристики
Availability > 0.99999
Certification EMC certificationSafety certificationManufacturing certification
Dimensions (H x W x D) Basic dimensions (excluding the parts protruding from the body): 44.4 mm x 442.0 mm x 425.0 mm (1.75 in. x 17.4 in. x 16.73 in.)Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 44.4 mm x 442.0 mm x 451.3 mm (1.75 in. x 17.4 in. x 17.77 in.)When 1150 W power modules are installed, they stretch out from the chassis. Therefore, the total depth of the switch changes to 541.1 mm (21.3 in.).
Flash 512 MB in total. To view the available flash memory size, run the display version command.
Item Description
Maximum power consumption (100% throughput, full speed of fans) Using 650 W DC or 500 W AC power modulesNot providing the PoE function: 68.3 W (without card)100% PoE loads: 925 W (system power consumption: 185.8 W, PoE: 739.2 W, without card)Using 1150 W AC or 1000 W AC power modulesNot providing the PoE function: 68.3 W (without card)100% PoE loads: 1733 W (system power consumption: 293 W, PoE: 1440 W, without card)
Maximum voltage range 90 V AC to 264 V AC, 47 Hz to 63 Hz-38.4 V DC to -72 V DC
Mean time between failures (MTBF) 43.28 years
Mean time to repair (MTTR) 2 hours
Memory (RAM) 1 GB
Noise under normal temperature (27°C, sound power) < 64.3 dB(A)
Operating altitude 0-5000 m (0-16404 ft.)
Operating Temperature 0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)NOTE:When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).The operating temperature of the switch is 0°C to 40°C (32°F to 104°F) when it uses QSFP+ optical modules with 10 km or longer transmission distances.
PoE Supported
Power supply surge protection Using 500 W AC or 1000 W AC power modules: ±6 kV in differential mode, ±6 kV in common modeUsing 650 W DC or 1150 W AC power modules: ±2 kV in differential mode, ±4 kV in common mode
Rated voltage range 100 V AC to 240 V AC, 50/60 Hz-48 V DC to -60 V DC
Relative humidity 5% to 95%, noncondensing
RPS Not supported
RTC Supported
Service port surge protection Common mode: ±7 kV
Short-term operating temperature -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)NOTE:When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.
Stack ports Any 10GE SFP+ or 40GE QSFP+ portsPorts on the 2-port QSFP+ rear stack card
Storage temperature -40°C to +70°C (-40°F to +158°F)
Typical power consumption (30% of traffic load)Tested according 50.1 W (without card)