S5730-68C-PWR-SI is a Huawei S5730-68C-PWR-SI Bundle, providing 48 x Ethernet 10/100/1,000 ports, 4 x 10 Gig SFP+, PoE+, with 1 interface slot. Huawei S5730-SI series switches are next-generation standard gigabit Layer 3 Ethernet switches that provide flexible full gigabit access and cost-effective fixed GE ports and 10 GE uplink ports, meanwhile can provide 40 GE uplink ports with an interface card. The S5730-SI was developed based on next-generation high-performing hardware and the Huawei Versatile Routing Platform (VRP). The S5730-SI supports simplified Operations and Maintenance (O&M), intelligent Stack (iStack), flexible Ethernet networking. It also provides enhanced Layer 3 features and mature IPv6 features. The S5730-SI can be used as an access or aggregation switch on a campus network or as an access switch in a data center.
Quick Spec
Table 1 shows the quick spec.
SKU |
S5730-68C-PWR-SI |
Ports |
48 PoE+ 10/100/1000BASE-T ports, 4 x 10 Gig SFP+ |
Slots |
One interface slot |
Forwarding performance |
240 Mpps |
Switching capacity |
680 Gbit/s |
PoE Supported |
PoE+ Supported |
Dimensions (W x D x H) |
442 mm x 420 mm x 44.4 mm |
Product Details
Figure 1 shows the front view of S5730-68C-PWR-SI.
Note:
① |
One ETH management port |
④ |
One USB port |
② |
PNP button |
⑤ |
Four 10GE SFP+ ports |
③ |
One console port |
⑥ |
48 PoE+ 10/100/1000BASE-T ports |
Figure 2 shows the back view of S5730-68C-PWR-SI.
Note:
① |
Ground screw |
④ |
Fan slot |
② |
ESN label |
⑤ |
Power module slot 2 |
③ |
Rear card slot |
⑥ |
Power module slot 1 |
The Options
Table 2 shows the recommended optional accessories.
Model |
Description |
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module (850nm,0.5km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm,10km, LC) |
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm,40km, LC) |
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module (1550nm,40km, LC) |
S-SFP-GE-LH80-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module (1550nm,80km, LC) |
eSFP-GE-ZX100-SM1550 |
eSFP, GE, Single-mode Module (1550nm,100km, LC) |
SFP-1000BaseT |
1000BASE-T (RJ45) SFP Electrical Module, Auto Negotiate,100m |
SFP-10G-USR |
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module (850nm,0.1km, LC) |
OSXD22N00 |
Optical Transceiver, SFP+, 10G, Multi-mode Module (1310nm,0.22km, LC, LRM) |
OMXD30000 |
Huawei Optical Transceiver OMXD30000, SFP+,10G, Multi-mode Module (850nm,0.3km, LC) |
SFP-10G-iLR |
Optical Transceiver, SFP+,9.8G, Single-mode Module (1310nm,1.4km, LC) |
OSX010000 |
Optical Transceiver, SFP+,10G, Single-mode Module (1310nm,10km, LC) |
OSX040N01 |
SFP+, 10G, Single-mode Module (1550nm,40km, LC) |
SFP-10G-ER-1310 |
Optical Transceiver, SFP+,10G, Single-mode Module (1310nm,40km, LC) |
SFP-10G-CU3M |
Huawei SFP+,10G, High Speed Direct-attach Cables,3m, SFP+20M, CC2P0.254B(S), SFP+20M, Used indoor |
Compare to Similar Items
Table 3 shows the comparison.
Item |
S5730-48C-SI-AC |
S5730-48C-PWR-SI-AC |
S5730-68C-SI-AC |
S5730-68C-PWR-SI-AC |
S5730-68C-PWR-SI |
Fixed Ports |
24 x 10/100/1,000 Base-T, 8 x 10 Gig SFP+ |
24 x 10/100/1,000 Base-T, 8 x 10 Gig SFP+ |
48 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ |
48 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ |
48 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ |
MAC Address Table |
32K MAC |
32K MAC |
32K MAC |
32K MAC |
32K MAC |
Dimensions (W x D x H) |
442 mm x 420 mm x 44.4 mm |
442 mm x 420 mm x 44.4 mm |
442 mm x 420 mm x 44.4 mm |
442 mm x 420 mm x 44.4 mm |
442 mm x 420 mm x 44.4 mm |
Slot |
One extended slot that supports an interface card: 4 x 40 GE QSFP+ interface card |
One extended slot that supports an interface card: 4 x 40 GE QSFP+ interface card |
One extended slot that supports an interface card: 4 x 40 GE QSFP+ interface card |
One extended slot that supports an interface card: 4 x 40 GE QSFP+ interface card |
One extended slot that supports an interface card: 4 x 40 GE QSFP+ interface card |
Get More Information
Do you have any question about the S5730-68C-PWR-SI?
Contact us now via Live Chat or info@itg-spb.ru.
S5730-68C-PWR-SI Specification |
|
Fixed Ports |
48 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ |
PoE Supported |
PoE+ Supported |
MAC Address Table |
32K MAC |
Dimensions (W x D x H) |
442 mm x 420 mm x 44.4 mm |
Slot |
One extended slot that supports an interface card: 4 x 40 GE QSFP+ interface card |
Input Voltage |
AC: Rated AC voltage: 100V to 240V; 50/60 Hz Max AC voltage: 90V to 264V; 47 Hz to 63 Hz |
DC: Rated DC power: -48V to -60V Max DC voltage: -36V to -72V |
|
Maximum Power Consumption |
· Without card and PD: 68.3W · Without card and full PoE load: 925W (switch power consumption: 185W, PoE: 740W) with AC 500W/DC 650W power supply · Without card and full PoE load: 1,733W (switch power consumption: 294W, PoE: 1,440W) with AC 1,150W power supply |
Typical Power Consumption (without PD) Operating Temperature |
Without card: 50.1W |
0m to 1,800m altitude: 0°C to 45°C (long-term); -5°C to 50°C (short-term) |
|
Relative Humidity |
5% to 95% (non-condensing) |
Heat Dissipation |
Heat dissipation using fans supporting intelligent speed adjustment |
Surge Protection |
Surge protection capability of service ports: 7 kV |
MAC Address Table |
IEEE 802.1d compliance |
32K MAC address entries |
|
MAC address learning and aging |
|
Static, dynamic, and blackhole MAC address entries |
|
Packet filtering based on source MAC addresses |
|
VLAN |
4094 VLANs |
Guest VLAN and voice VLAN |
|
GVRP |
|
MUX VLAN |
|
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports |
|
1:1 and N:1 VLAN mapping |
|
Reliability |
RRPP ring topology and RRPP multi-instance |
Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover |
|
SEP |
|
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
|
ERPS (G.8032) |
|
BPDU protection, root protection, and loop protection |
|
IP Routing |
Static route, RIPv1/v2, RIPng, OSPF, OSPFv3, ECMP, IS-IS, IS-ISv6, BGP, BGP4+, VRRP, and VRRP6 |
Multicast |
PIM DM, PIM SM, and PIM SSM |
IGMP v1/v2/v3 and IGMP v1/v2/v3 snooping and IGMP fast leave |
|
MLD v1/v2 and MLD v1/v2 snooping |
|
Multicast forwarding in a VLAN and multicast replication between VLANs |
|
Multicast load balancing among member ports of a trunk |
|
Controllable multicast |
|
Port-based multicast traffic statistics |
|
IPv6 Features |
Neighbor Discovery (ND) |
Path MTU (PMTU) |
|
IPv6 ping, IPv6 tracert, and IPv6 Telnet |
|
6to4 tunnel, ISATAP tunnel, and manually configured tunnel |
|
ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type |
|
QoS/ACL |
Rate limiting on packets sent and received by a port |
Packet redirection |
|
Port-based traffic policing and two-rate three-color CAR |
|
Eight queues on each port |
|
WRR, DRR, SP, WRR + SP, and DRR + SP queue scheduling algorithms |
|
Re-marking of the 802.1p priority and DSCP priority |
|
Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID |
|
Rate limiting in each queue and traffic shaping on ports |
|
Security |
Hierarchical user management and password protection |
DoS attack defense, ARP attack defense, and ICMP attack defense |
|
Binding of the IP address, MAC address, port number, and VLAN ID |
|
Port isolation, port security, and sticky MAC |
|
MFF |
|
Blackhole MAC address entries |
|
Limit on the number of learned MAC addresses |
|
IEEE 802.1x authentication and limit on the number of users on a port |
|
AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC |
|
SSH v2.0 |
|
HTTPS |
|
CPU defense |
|
Blacklist and whitelist |
|
IEEE 802.1x authentication, MAC address authentication, and Portal authentication |
|
DHCPv4/v6 client/relay/server/snooping |
|
Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets |
|
SVF |
Plug-and-play SVF client |
Automatic software and patch loading to clients |
|
One-click and automatic delivery of service configurations |
|
Independent client running |
|
OAM |
Software OAM |
EFM OAM |
|
CFM OAM |
|
Y.1731 performance test |
|
Management and Maintenance |
iStack (using service ports as stack ports) |
Virtual cable test |
|
SNMP v1/v2c/v3 |
|
RMON |
|
Web-based NMS |
|
System logs and alarms of different levels |
|
802.3az EEE |
|
sFlow |
|
Intelligent O&M |
|
Interoperability |
Supports VBST (compatible with PVST/PVST+/RPVST) |
Supports LNP (similar to DTP) |
|
Supports VCMP (similar to VTP) |
Характеристики | |
1:1 and N:1 VLAN mapping | Reliability |
32K MAC address entries | MAC address learning and aging |
6to4 tunnel, ISATAP tunnel, and manually configured tunnel | ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type |
AAA authentication, RADIUS authentication, HWTACACS authenticati | SSH v2.0 |
Automatic software and patch loading to clients | One-click and automatic delivery of service configurations |
Binding of the IP address, MAC address, port number, and VLAN ID | Port isolation, port security, and sticky MAC |
Blacklist and whitelist | IEEE 802.1x authentication, MAC address authentication, and Portal authentication |
CFM OAM | Y.1731 performance test |
Controllable multicast | Port-based multicast traffic statistics |
DC:Rated DC power: -48V to -60VMax DC voltage: -36V to -72V | Maximum Power Consumption |
DHCPv4/v6 client/relay/server/snooping | Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets |
Dimensions (W x D x H) | 442 mm x 420 mm x 44.4 mm |
Eight queues on each port | WRR, DRR, SP, WRR + SP, and DRR + SP queue scheduling algorithms |
ERPS (G.8032) | BPDU protection, root protection, and loop protection |
Fixed ports | 48 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ |
Guest VLAN and voice VLAN | GVRP |
Heat dissipation | Heat dissipation using fans supporting intelligent speed adjustment |
Hierarchical user management and password protection | DoS attack defense, ARP attack defense, and ICMP attack defense |
HTTPS | CPU defense |
IGMP v1/v2/v3 and IGMP v1/v2/v3 snooping and IGMP fast leave | MLD v1/v2 and MLD v1/v2 snooping |
Independent client running | OAM |
Input voltage | AC:Rated AC voltage: 100V to 240V; 50/60 HzMax AC voltage: 90V to 264V; 47 Hz to 63 Hz |
Interoperability | Supports VBST (compatible with PVST/PVST+/RPVST) |
IP Routing | Static route, RIPv1/v2, RIPng, OSPF, OSPFv3, ECMP, IS-IS, IS-ISv6, BGP, BGP4+, VRRP, and VRRP6 |
IPv6 features | Neighbor Discovery (ND) |
Limit on the number of learned MAC addresses | IEEE 802.1x authentication and limit on the number of users on a port |
MAC Address Table | IEEE 802.1d compliance |
Management and Maintenance | iStack (using service ports as stack ports) |
MFF | Blackhole MAC address entries |
Multicast | PIM DM, PIM SM, and PIM SSM |
Multicast forwarding in a VLAN and multicast replication between | Multicast load balancing among member ports of a trunk |
MUX VLAN | VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports |
Packet redirection | Port-based traffic policing and two-rate three-color CAR |
Path MTU (PMTU) | IPv6 ping, IPv6 tracert, and IPv6 Telnet |
PoE Supported | PoE+ Supported |
QoS/ACL | Rate limiting on packets sent and received by a port |
Rate limiting in each queue and traffic shaping on ports | Security |
Re-marking of the 802.1p priority and DSCP priority | Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID |
Relative humidity | 5% to 95% (non-condensing) |
RMON | Web-based NMS |
RRPP ring topology and RRPP multi-instance | Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover |
SEP | STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
sFlow | Intelligent O&M |
Slot | One extended slot that supports an interface card: 4 x 40 GE QSFP+ interface card |
Software OAM | EFM OAM |
Static, dynamic, and blackhole MAC address entries | Packet filtering based on source MAC addresses |
Supports LNP (Similar to DTP) | Supports VCMP (similar to VTP) |
Surge Protection | Surge protection capability of service ports: 7 kV |
SVF | Plug-and-play SVF client |
System logs and alarms of different levels | 802.3az EEE |
Virtual cable test | SNMP v1/v2c/v3 |
VLAN | 4094 VLANs |
Without card: 50.1W | 0m to 1,800m altitude: 0°C to 45°C (long-term); -5°C to 50°C (short-term) 1,800m to 5,000m altitude: The operating temperature reduces by 1°C for each 220m increase in altitude. |
· Without card and PD: 68.3W· Without card and full PoE load: 92 | Typical Power Consumption (without PD)Operating Temperature |
Теги: S5730-68C-PWR-SI Huawei