S5730-60C-PWH-HI is a Huawei S5730-HI switch, providing 48 x 10/100/1,000 BASE-T ports, 4 x 10 GE SFP+ ports, 1 expansion slot, PoE++, without power module. Huawei S5730-HI gigabit Ethernet switches are Huawei-developed next-generation agile switches that provide fixed full gigabit access and 10 GE uplink interfaces as well as one or two slots for uplink interface extension. The switches are developed based on Huawei Versatile Routing Platform (VRP) to implement software definition and service change on demand. With services and network convergence as the core, the switches provide the free mobility function to ensure consistent user experience. The Super Virtual Fabric (SVF) function virtualizes the entire network into one device. In addition, the switches support flexible Ethernet networking, comprehensive VPN tunnel solutions, various security control methods, intelligent deployment, and simple Operations and Maintenance (O&M). The S5730-HI series switches are the best choices for the access or aggregation layers of medium and large-sized campus networks, and the core layer of branch or small campus networks.
Quick Spec
Table 1 shows the quick spec.
SKU |
S5730-60C-PWH-HI |
Ports |
48 x 10/100/1,000 BASE-T ports, 4 x 10 GE SFP+ ports |
Slots |
1 extended slot |
Power Supply |
1+1 power backup, with AC, DC, or AC + DC power supply |
PoE Supported |
PoE++ |
Switching capacity |
758 Gbit/s |
Dimensions (W x D x H) |
442 mm x 420 mm x 44.4 mm |
Product Details
Figure 1 shows the front view of S5730-60C-PWH-HI.
Note:
① |
One ETH management port |
④ |
One USB port |
② |
PNP button |
⑤ |
Four 10GE SFP+ ports |
③ |
One console port |
⑥ |
48 x 10/100/1,000 Base-T Ethernet ports |
Figure 2 shows the back view of S5730-60C-PWH-HI.
Note:
① |
Ground screw |
⑤ |
Fan |
② |
SSD Card Slot |
⑥ |
Power module slot 2 |
③ |
ESN label |
⑦ |
Power module slot 1 |
④ |
Rear card slot |
|
The Options
Table 2 shows the recommended optional accessories.
Model |
Description |
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module (850nm,0.5km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm,10km, LC) |
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm,40km, LC) |
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module (1550nm,40km, LC) |
S-SFP-GE-LH80-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module (1550nm,80km, LC) |
eSFP-GE-ZX100-SM1550 |
eSFP, GE, Single-mode Module (1550nm,100km, LC) |
SFP-1000BaseT |
1000BASE-T (RJ45) SFP Electrical Module, Auto Negotiate,100m |
SFP-10G-USR |
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module (850nm,0.1km, LC) |
OSXD22N00 |
Optical Transceiver, SFP+, 10G, Multi-mode Module (1310nm,0.22km, LC, LRM) |
OMXD30000 |
Huawei Optical Transceiver OMXD30000, SFP+,10G, Multi-mode Module (850nm,0.3km, LC) |
SFP-10G-iLR |
Optical Transceiver, SFP+,9.8G, Single-mode Module (1310nm,1.4km, LC) |
OSX010000 |
Optical Transceiver, SFP+,10G, Single-mode Module (1310nm,10km, LC) |
OSX040N01 |
SFP+, 10G, Single-mode Module (1550nm,40km, LC) |
SFP-10G-ER-1310 |
Optical Transceiver, SFP+,10G, Single-mode Module (1310nm,40km, LC) |
SFP-10G-CU3M |
Huawei SFP+,10G, High Speed Direct-attach Cables,3m, SFP+20M, CC2P0.254B(S), SFP+20M, Used indoor |
Compare to Similar Items
Table 3 shows the comparison.
Item |
S5730-60C-HI |
S5730-60C-PWH-HI |
S5730-68C-HI |
S5730-68C-PWH-HI |
Fixed Ports |
48 x 10/100/1,000 Base-T ports, 4 x 10 GE SFP+ ports |
48 x 10/100/1,000 Base-T (PoE++) ports, 4 x 10 GE SFP+ ports |
48 x 10/100/1,000 Base-T ports, 4 x 10 GE SFP+ ports |
48 x 10/100/1,000 Base-T (PoE++) ports, 4 x 10 GE SFP+ ports |
Dimensions (W x D x H) |
442 mm x 420 mm x 44.4 mm |
442 mm x 420 mm x 44.4 mm |
442 mm x 420 mm x 44.4 mm |
442 mm x 420 mm x 44.4 mm |
Extended Slots |
One extended slot, supporting 8-port 10 GE electrical, 8-port 10 GE optical, or 2-port 40 GE optical interface card |
One extended slot, supporting 8-port 10 GE electrical, 8-port 10 GE optical, or 2-port 40 GE optical interface card |
Two extended slots (one of them is reserved), supporting 8-port 10 GE electrical, 8-port 10 GE optical, or 2-port 40 GE optical interface card |
Two extended slots (one of them is reserved), supporting 8-port 10 GE electrical, 8-port 10 GE optical, or 2-port 40 GE optical interface card |
Get More Information
Do you have any question about the S5730-60C-PWH-HI?
Contact us now via Live Chat or info@itg-spb.ru.
S5730-60C-PWH-HI Specification |
|
Fixed Ports |
48 x 10/100/1,000 Base-T (PoE++) ports, 4 x 10 GE SFP+ ports |
Dimensions (W x D x H) |
442 mm x 420 mm x 44.4 mm |
Extended Slots |
One extended slot, supporting 8-port 10 GE electrical, 8-port 10 GE optical, or 2-port 40 GE optical interface card |
Input Voltage |
AC: |
DC: |
|
Maximum Power Consumption |
· 500W AC/650W DC: 106W (without PDs); 830W (with PDs, PDs: 739.2W) · 1,150W AC: 119.7W (without PDs); 1,610W (with PDs, PDs: 1,440W) |
Operating Temperature |
0m to 1,800m altitude: 0°C to 45°C |
Relative Humidity |
5% to 95% (non-condensing) |
Heat Dissipation |
Air cooling heat dissipation, intelligent speed adjustment, and pluggable fans |
MAC Address Table |
IEEE 802.1d standards compliance |
256K MAC address entries |
|
MAC address learning and aging |
|
Static, dynamic, and blackhole MAC address entries |
|
Packet filtering based on source MAC addresses |
|
VLAN |
4094 VLANs |
Guest VLAN and voice VLAN |
|
GVRP |
|
MUX VLAN |
|
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports |
|
VLAN mapping |
|
Wireless Service |
AP access control, AP domain management, and AP configuration template management |
Radio band management, unified static configuration, and dynamic centralized management |
|
WLAN basic services, QoS, security, and user management |
|
CAPWAP, tag/terminal location, and spectrum analysis |
|
Ethernet Loop Protection |
RRPP ring topology and RRPP multi-instance |
Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover |
|
SEP |
|
ERPS (G.8032) |
|
BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM |
|
STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
|
BPDU protection, root protection, and loop protection |
|
MPLS |
MPLS L3VPN |
MPLS L2VPN (VPWS/VPLS) |
|
MPLS-TE |
|
MPLS QoS |
|
IP Routing |
Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, and routing policy |
Interoperability |
VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST |
Link-type Negotiation Protocol (LNP), similar to DTP |
|
VLAN Central Management Protocol (VCMP), similar to VTP |
|
IPv6 Features |
Neighbor Discover (ND) |
PMTU |
|
IPv6 Ping, IPv6 Tracert, and IPv6 Telnet |
|
ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types |
|
Multicast Listener Discovery snooping (MLDv1/v2) |
|
IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN |
|
Multicast |
IGMP v1/v2/v3 snooping and IGMP fast leave |
Multicast forwarding in a VLAN and multicast replication between VLANs |
|
Multicast load balancing among member ports of a trunk |
|
Controllable multicast |
|
Port-based multicast traffic statistics |
|
IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM |
|
MSDP |
|
MVPN |
|
QoS/ACL |
Rate limitation in the inbound and outbound directions of a port |
Packet redirection |
|
Port-based traffic policing and two-rate three-color CAR |
|
Eight queues on each port |
|
DRR, SP, and DRR + SP queue scheduling algorithms |
|
WRED |
|
Re-marking of the 802.1p and DSCP fields of packets |
|
Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID |
|
Queue-based rate limitation and shaping on ports |
|
Security |
Hierarchical user management and password protection |
DoS attack defense, ARP attack defense, and ICMP attack defense |
|
Binding of the IP address, MAC address, port number, and VLAN ID |
|
Port isolation, port security, and sticky MAC |
|
MAC Forced Forwarding (MFF) |
|
Blackhole MAC address entries |
|
Limit on the number of learned MAC addresses |
|
IEEE 802.1x authentication and limit on the number of users on a port |
|
AAA authentication, RADIUS authentication, and HWTACACS authentication |
|
NAC |
|
SSH V2.0 |
|
HTTPS |
|
CPU protection |
|
Blacklist and whitelist |
|
Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets |
|
Secure Boot |
|
IPSec |
|
ECA |
|
Deception |
|
Reliability |
LACP |
E-trunk |
|
Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag) |
|
ITU-Y.1731 |
|
DLDP |
|
LLDP |
|
BFD for BGP, BFD for IS-IS, BFD for OSPF, and BFD for static route |
|
VXLAN |
VXLAN L2 and L3 gateways |
Centralized and distributed gateway |
|
BGP-EVPN |
|
Configured through the NETCONF protocol |
|
Super Virtual Fabric (SVF) |
The S5730-HI can work as the parent node to vertically virtualize downlink switches and APs as one device for management |
A two-layer client architecture is supported |
|
IGMP snooping can be enabled on Access Switches (ASs) and the maximum number of access users on a port can be configured |
|
ASs can be independently configured. Services that are not supported by templates can be configured on the parent |
|
Third-party devices are allowed between SVF parent and clients |
|
iPCA |
Directly coloring service packets to collect real-time statistics on the number of lost packets and packet loss ratio |
Collection of statistics on the number of lost packets and packet loss ratio at network and device levels |
|
TWAMP |
Two-way IP link performance measurement |
Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter |
|
Management and Maintenance |
iStack |
Virtual cable test |
|
SNMP v1/v2c/v3 |
|
RMON |
|
Web-based NMS |
|
System logs and alarms of different levels |
|
GVRP |
|
MUX VLAN |
|
802.3az Energy Efficient Ethernet (EEE) |
|
NetStream |
|
Dying gasp upon power-off |
|
Intelligent O&M |
Характеристики | |
0m to 1,800m altitude: 0°C to 45°C 1,800m to 5,000m altitude: Th | Relative Humidity |
4094 VLANs | Guest VLAN and voice VLAN |
5% to 95% (non-condensing) | Heat Dissipation |
802.3az Energy Efficient Ethernet (EEE) | NetStream |
ACLs based on source IPv6 addresses, destination IPv6 addresses, | Multicast Listener Discovery snooping (MLDv1/v2) |
Air cooling heat dissipation, intelligent speed adjustment, and | MAC Address Table |
BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM | STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
Blackhole MAC address entries | Limit on the number of learned MAC addresses |
Blacklist and whitelist | Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets |
BPDU protection, root protection, and loop protection | MPLS |
CAPWAP, tag/terminal location, and spectrum analysis | Ethernet Loop Protection |
Centralized and distributed gateway | BGP-EVPN |
Configured through the NETCONF protocol | Super Virtual Fabric (SVF) |
DC: Rated DC voltage: -48V to -60V Max. DC voltage: -38.4V to -7 | Maximum Power Consumption (without cards) |
Dimensions (W x D x H) | 442 mm x 420 mm x 44.4 mm |
Directly coloring service packets to collect real-time statistic | Collection of statistics on the number of lost packets and packet loss ratio at network and device levels |
DoS attack defense, ARP attack defense, and ICMP attack defense | Binding of the IP address, MAC address, port number, and VLAN ID |
Dying gasp upon power-off | Intelligent O&M |
E-trunk | Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag) |
ECA | Deception |
Eight queues on each port | DRR, SP, and DRR + SP queue scheduling algorithms |
Extended slots | One extended slot, supporting 8-port 10 GE electrical, 8-port 10 GE optical, or 2-port 40 GE optical interface card |
Fixed ports | 48 x 10/100/1,000 Base-T (PoE++) ports, 4 x 10 GE SFP+ ports |
GVRP | MUX VLAN |
HTTPS | CPU protection |
IEEE 802.1d standards compliance | 256K MAC address entries |
IEEE 802.1x authentication and limit on the number of users on a | AAA authentication, RADIUS authentication, and HWTACACS authentication |
IGMP snooping can be enabled on Access Switches (ASs) and the ma | ASs can be independently configured. Services that are not supported by templates can be configured on the parent |
IGMP v1/v2/v3 snooping and IGMP fast leave | Multicast forwarding in a VLAN and multicast replication between VLANs |
Input voltage | AC: Rated AC voltage: 100V to 240V; 50/60 Hz Max. AC voltage: 90V to 264V; 47 Hz to 63 Hz |
Interoperability | VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST |
IP Routing | Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, and routing policy |
IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and | Multicast |
IPv6 features | Neighbor Discover (ND) |
iStack | Virtual cable test |
ITU-Y.1731 | DLDP |
Link-type Negotiation Protocol (LNP), similar to DTP | VLAN Central Management Protocol (VCMP), similar to VTP |
LLDP | BFD for BGP, BFD for IS-IS, BFD for OSPF, and BFD for static route |
MAC address learning and aging | Static, dynamic, and blackhole MAC address entries |
Measurement on two-way packet delay, one-way packet loss rate, a | Management and Maintenance |
MPLS L3VPN | MPLS L2VPN (VPWS/VPLS) |
MPLS-TE | MPLS QoS |
MSDP | MVPN |
Multicast load balancing among member ports of a trunk | Controllable multicast |
NAC | SSH V2.0 |
Packet filtering at Layer 2 to Layer 4, filtering out invalid fr | Queue-based rate limitation and shaping on ports |
Packet filtering based on source MAC addresses | VLAN |
Packet redirection | Port-based traffic policing and two-rate three-color CAR |
PMTU | IPv6 Ping, IPv6 Tracert, and IPv6 Telnet |
Port isolation, port security, and sticky MAC | MAC Forced Forwarding (MFF) |
Port-based multicast traffic statistics | IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM |
QoS/ACL | Rate limitation in the inbound and outbound directions of a port |
Radio band management, unified static configuration, and dynamic | WLAN basic services, QoS, security, and user management |
Reliability | LACP |
RRPP ring topology and RRPP multi-instance | Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover |
Secure Boot | IPSec |
Security | Hierarchical user management and password protection |
SEP | ERPS (G.8032) |
SNMP v1/v2c/v3 | RMON |
The S5730-HI can work as the parent node to vertically virtualiz | A two-layer client architecture is supported |
Third-party devices are allowed between SVF parent and clients | iPCA |
TWAMP | Two-way IP link performance measurement |
VLAN assignment based on MAC addresses, protocols, IP subnets, p | VLAN mapping |
VXLAN | VXLAN L2 and L3 gateways |
Web-based NMS | System logs and alarms of different levels |
Wireless service | AP access control, AP domain management, and AP configuration template management |
WRED | Re-marking of the 802.1p and DSCP fields of packets |
· 500W AC/650W DC:106W (without PDs);830W (with PDs, PDs: 739.2W | Operating Temperature |
Теги: S5730-60C-PWH-HI Huawei