+7 (812) 309 34 73. Договоримся!
NE40E-X16A Basic Configuration CR5P16BASD77 (Including NE40E-X16A Chassis, 2 MPUs, 4 SFUs(1 T),10 DC Power,6 Fan Tray, without Software Charge and Document).
Quick Specs
Figure 1 shows the appearance of Huawei Router - CR5P16BASD77.
Table 1 shows the Quick Specs.
Product Code |
Huawei Router - CR5P16BASD77 |
Switching Capacity |
12.58 Tbit/s |
Forwarding Performance |
5,760 Mpps |
MPU Slots |
2 |
SFU Slots |
4 |
LPU Slots |
16 |
Service Card Slots |
Maximum 48 |
Dimensions (W x H x D) |
1,420 mm x 442 mm x 650 mm (32U) |
Product Details
Figure 2 shows the front panel of Huawei Router - CR5P16BASD77.
Note:
① |
Air intake vent |
② |
MPU slot |
③ |
Front cable management tray |
④ |
SFU slot |
⑤ |
LPU slot |
Figure 3 shows the back panel of Huawei Router - CR5P16BASD77.
Note:
① |
Fan module |
② |
Filler Panel |
③ |
DC power entry module (PEM) |
④ |
Rear cable management tray |
⑤ |
Power monitoring module |
⑥ |
Ground terminal |
The Optical transceiver
Table 2 shows the recommended elements for the Huawei Router - CR5P16BASD77.
Model |
Description |
FE-SFP Optical Transceiver |
|
SFP-FE-SX-MM1310 |
SFP,100M/155M,Multi-mode Module(1310nm,2km,LC) |
eSFP-FE-LX-SM1310 |
eSFP,100M/155M,Single-mode Module(1310nm,15km,LC) |
S-SFP-FE-LH40-SM1310 |
eSFP,FE,Single-mode Module(1310nm,40km,LC) |
GE-SFP Optical Transceiver |
|
SFP-1000BaseT |
SFP,GE,Electrical Interface Module(100m,RJ45) |
eSFP-GE-SX-MM850 |
eSFP,GE,Multi-mode Module(850nm,0.55km,LC) |
SFP-GE-LX-SM1310 |
eSFP,GE,Single-mode Module(1310nm,10km,LC) |
S-SFP-GE-LH40-SM1310 |
eSFP,GE,Single-mode Module(1310nm,40km,LC) |
S-SFP-GE-LH40-SM1550 |
eSFP,GE,Single-mode Module(1550nm,40km,LC) |
Compare to Similar Items
Table 3 shows the comparison between CR5P16BASD77 and CR5P08BASA71.
Model |
CR5P16BASD77 |
CR5P08BASA71 |
Switching Capacity |
12.58 Tbit/s |
25.16 Tbit/s |
Forwarding Performance |
5,760 Mpps |
5,760 Mpps |
MPU Slots |
2 |
2 |
SFU Slots |
4 |
2 |
LPU Slots |
16 |
8 |
Dimensions (W x H x D) |
1,420 mm x 442 mm x 650 mm (32U) |
442 mm x 650 mm x 934 mm (21U) |
Get more information
Do you have any question about the CR5P16BASD77?
Contact us now via Live Chat or info@itg-spb.ru.
CR5P16BASD77 Specification |
|
Switching Capacity |
50.32 Tbit/s |
Forwarding Performance |
11,520 Mpps |
Number of Slots |
22 slots, including 2 MPUs (1:1 backup), 4 SFUs (3+1 backup), and 16 LPUs |
Dimensions (W x D x H) |
442 mm x 650 mm x 1,778 mm (40U) |
Power Consumption (in full configuration) |
9,040W (480G) |
Weight (in full configuration) |
356 kg (480G) |
Interface Types |
100 GE/40 GE 10 GE- LAN/WAN GE/FE OC-192c/STM-64c POS OC-48c/STM-16c POS OC-12c/STM-4c POS OC-3c/STM-1cPOS Channelized OC-3/STM-1 Channelized STM-4 OC-3c/STM-1c ATM OC-12c/STM-4c ATM E3/T3 CE1/CT1 |
IPv4 |
Support for static routing as well as dynamic routing protocols, such as RIP, OSPF, IS-IS, and BGP-4 Line rate forwarding on all interfaces in complex routing environments, for example, when route flapping occurs |
IPv6 |
Various IPv4-to-IPv6 transition technologies: manual tunnel, automatic tunnel, 6to4 tunnel, GRE tunnel, and ISATAP tunnel IPv4 over IPv6 tunnel and IPv6 Provider Edge (6PE) IPv6 static routes and dynamic routing protocols, such as BGP4+, RIPng, OSPFv3, and IS-ISv6 IPv6 neighbor discovery, PMTU discovery, TCP6, ping IPv6, tracert IPv6, socket IPv6, static IPv6 DNS, IPv6 DNS server, TFTP IPv6 client, and IPv6 policy-based routing Internet Control Message Protocol Version 6 (ICMPv6), Management Information Base (MIB), User Datagram Protocol Version 6 (UDP6) MIB, TCP6 MIB, and IPv6 MIB L2NAT, NAT444, DS-Lite, and NAT64 |
MPLS |
MPLS TE and MPLS/BGP VPN, in compliance with RFC 2547 Inter-AS VPN Option A/B/C Integration with Internet services Martini and Kompella MPLS L2VPN L2VPN techniques, such as VPLS and VLL IP interworking over heterogeneous media Multicast VPN MPLS-TP, EVPN, Remote LFA |
Layer 2 Features |
IEEE 802.1Q, IEEE802.1ad, IEEE 802.1D, IEEE 802.1w, and IEEE 802.1s VLAN aggregation (super VLAN) Filtering list based on MAC addresses and ports 1483B |
Reliability |
IP/LDP/VPN/TE/VLL FRR Protection mechanisms such as IP/TE auto rerouting, IGP/BGP/multicast route convergence, VRRP, RRPP, IP-Trunk load balancing and backup, BFD, MPLS/Ethernet OAM, Y.1731, and routing protocol/port/VLAN damping PW redundancy, E-Trunk, E-APS, and E-STP In-service patching for smooth software upgrade Passive backplane design Redundancy backup for key components, such as route processing modules, SFUs, and power modules to guard against single points of failure Switching between components that hot-back up each other GR, NSF, NSR, and ISSU Hot swap of all components |
QoS |
Well-designed HQoS and advanced scheduling and congestion avoidance technologies on each LPU Accurate traffic policing and traffic shaping Complex rule definition and fine-grained flow identification MPLS H-QoS, ensuring QoS for MPLS VPN, VLL, and PWE3 services 8CT that combines MPLS TE and the DiffServ model TE-tunnel-oriented QoS |
OAM |
Y.1731, IP FPM, RFC 2544, MPLS OAM, 802.1ag, and 802.3ah, OPS |
Multicast |
IGMPv1, IGMPv2, and IGMPv3 Multicast routing protocols, including PIM-DM, PIM-SM, PIM-SSM, Multicast Source Discovery Protocol (MSDP), and Multiprotocol BGP (MBGP) Static multicast Multicast CAC Interoperability between multicast protocols Processing of multicast policies based on multicast routing protocols and multicast forwarding Multicast QoS and multicast replication for IPoE access users Two-level multicast replication on the SFUs and LPUs to optimize the multicast effect |
Security |
ACL-based packet filtering URPF GTSM DHCP snooping ARP attack defense and DoS attack defense MAC address limit and MAC-IP binding Secure Shell (SSH) and SSH version 2 (SSH v2) BGP-Flowspec RIPv2, OSPF, IS-IS, and BGP MD5, SHA256, Keychain |
Value-added Services |
IPsec tunnel Distributed GRE tunnel Distributed NetStream High-precision NAT: CGN |
Environment Requirements |
Long-term operating temperature: 0°C to 45°C Short-term operating temperature: -5°C to 55°C Long-term operating humidity: 5% RH to 85% RH Short-term operating humidity: 0% RH to 100% RH Operating altitude: ≦ 3,000 meters |
Характеристики | |
Dimensions (W x D x H) | 442 mm x 650 mm x 1,778 mm (40U) |
Environment Requirements | Long-term operating temperature: 0°C to 45°CShort-term operating temperature: -5°C to 55°CLong-term operating humidity: 5% RH to 85% RHShort-term operating humidity: 0% RH to 100% RHOperating altitude: ≦ 3,000 meters |
Forwarding Performance | 11,520 Mpps |
Interface Types | 100 GE/40 GE10 GE- LAN/WANGE/FEOC-192c/STM-64c POSOC-48c/STM-16cPOS OC-12c/STM-4c POSOC-3c/STM-1cPOSChannelized OC-3/STM-1Channelized STM-4OC-3c/STM-1c ATMOC-12c/STM-4c ATME3/T3CE1/CT1 |
IPv4 | Support for static routing as well as dynamic routing protocols, such as RIP, OSPF, IS-IS, and BGP-4Line rate forwarding on all interfaces in complex routing environments, for example, when route flapping occurs |
IPv6 | Various IPv4-to-IPv6 transition technologies: manual tunnel, automatic tunnel, 6to4 tunnel, GRE tunnel, and ISATAP tunnelIPv4 over IPv6 tunnel and IPv6 Provider Edge (6PE)IPv6 static routes and dynamic routing protocols, such as BGP4+, RIPng, OSPFv3, and IS-ISv6IPv6 neighbor discovery, PMTU discovery, TCP6, ping IPv6, tracert IPv6, socket IPv6, static IPv6 DNS, IPv6 DNS server, TFTP IPv6 client, and IPv6 policy-based routingInternet Control Message Protocol Version 6 (ICMPv6), Management Information Base (MIB), User Datagram Protocol Version 6 (UDP6) MIB, TCP6 MIB, and IPv6 MIBL2NAT, NAT444, DS-Lite, and NAT64 |
Layer 2 features | IEEE 802.1Q, IEEE802.1ad, IEEE 802.1D, IEEE 802.1w, and IEEE 802.1sVLAN aggregation (super VLAN)Filtering list based on MAC addresses and ports1483B |
MPLS | MPLS TE and MPLS/BGP VPN, in compliance with RFC 2547Inter-AS VPN Option A/B/CIntegration with Internet servicesMartini and Kompella MPLS L2VPNL2VPN techniques, such as VPLS and VLLIP interworking over heterogeneous mediaMulticast VPNMPLS-TP, EVPN, Remote LFA |
Multicast | IGMPv1, IGMPv2, and IGMPv3Multicast routing protocols, including PIM-DM, PIM-SM, PIM-SSM, Multicast Source Discovery Protocol (MSDP), and Multiprotocol BGP (MBGP)Static multicastMulticast CACInteroperability between multicast protocolsProcessing of multicast policies based on multicast routing protocols and multicast forwardingMulticast QoS and multicast replication for IPoE access usersTwo-level multicast replication on the SFUs and LPUs to optimize the multicast effect |
Number of Slots | 22 slots, including2 MPUs (1:1 backup), 4 SFUs(3+1 backup), and 16 LPUs |
OAM | Y.1731, IP FPM, RFC 2544, MPLS OAM, 802.1ag, and 802.3ah, OPS |
Power consumption (in full configuration) | 9,040W (480G) |
QoS | Well-designed HQoS and advanced scheduling and congestion avoidance technologies on each LPUAccurate traffic policing and traffic shapingComplex rule definition and fine-grained flow identificationMPLS H-QoS, ensuring QoS for MPLS VPN, VLL, and PWE3 services8CT that combines MPLS TE and the DiffServ modelTE-tunnel-oriented QoS |
Reliability | IP/LDP/VPN/TE/VLL FRRProtection mechanisms such as IP/TE auto rerouting, IGP/BGP/multicast route convergence, VRRP, RRPP, IP-Trunk load balancing and backup, BFD, MPLS/Ethernet OAM, Y.1731, and routing protocol/port/VLAN dampingPW redundancy, E-Trunk, E-APS, and E-STPIn-service patching for smooth software upgradePassive backplane designRedundancy backup for key components, such as route processing modules, SFUs, and power modules to guard against single points of failureSwitching between components that hot-back up each otherGR, NSF, NSR, and ISSUHot swap of all components |
Security | ACL-based packet filteringURPFGTSMDHCP snoopingARP attack defense and DoS attack defenseMAC address limit and MAC-IP bindingSecure Shell (SSH) and SSH version 2 (SSH v2)BGP-FlowspecRIPv2, OSPF, IS-IS, and BGP MD5, SHA256, Keychain |
Switching capacity | 50.32 Tbit/s |
Value-added Services | IPsec tunnelDistributed GRE tunnelDistributed NetStreamHigh-precision NAT: CGN |
Weight (in full configuration) | 356 kg (480G) |
Теги: CR5P16BASD77 Huawei