OSN 9800 P32 subrack is an ultra-large capacity all-optical cross-connect product. It is mainly used at the backbone core layer and metro aggregation layer. It works with the OSN 9800/1800 to build a complete E2E WDM/OTN backbone transmission solution, achieving transparent and ultra-large capacity transmission.
View Overview of Huawei Transmission Network Hot Series
- Huawei OptiX OSN 1800
- Huawei OptiX OSN 500/550/580
- Huawei OptiX OSN 8800/6800/3800
- Huawei OptiX OSN 9800
- Huawei OptiX OSN 7500/7500 II
Quick Spec
Table 1 shows the quick spec.
Model |
Huawei OptiX OSN 9800 P32 |
|
Subrack dimensions (mm) |
1390 (H) x 496 (W) x 315 (D) (without cabinet) |
|
Suitable cabinet |
ETSI 300 cabinets, such as A63B |
|
Number of slots for service boards |
32 |
|
Switching capability |
Optical |
1 to 32-degree reconfigurable optical add/drop multiplexer (ROADM) |
Electrical |
N/A |
|
Max. number of wavelengths |
Fixed grid: 96 wavelengths @50 GHz grid Flex grid: The maximum number of wavelengths is related to the width of the flex channel. |
Product Details
Huawei OptiX OSN 9800 P32 Chassic:
Subrack Areas and Slots
Boards need to be installed in the designated slots in a subrack. The subrack runs on -48 V DC or -60 V DC.
The equipment includes the following areas: the power supply, system control, optical supervisory, and interface area, fan area, fiber routing area, and service board area. PIU boards are located in the power supply, system control, optical supervisory, and interface area. If an area has the same background color as a PIU board, the PIU board powers the boards located in this area.
Figure 1. Schematic diagram of the areas and slots in the OptiX OSN 9800 P32 subrack
Table 2 shows Descriptions of the areas and slots in the OptiX OSN 9800 P32 subrack.
Area |
Composition |
Slot |
Function |
Power supply, system control, optical supervisory, and interface area |
6 PIU boards (PIU) 2 CTU system control boards (TMP1CTU) 1 EFI board (TMP1EFI) 1 spectrum analyzer boards (TMP1MON32) |
PIU: IU100-IU102, IU110-IU112 CTU: IU105, IU107 EFI: IU106 MON32: IU108-IU109 Reserved slots: IU103-IU104 |
The PIU boards are in mutual backup. Therefore, the failure of any power input to the equipment does not affect the normal operation of the equipment. NOTE: The PIU boards on the left and right sides of the EFI board are in mutual backup, for example, the PIU boards in slots IU100 and IU110, the PIU boards in slots IU101 and IU111, and the PIU boards in slots IU102 and IU112. The system control boards are configured in 1+1 backup mode. The system control board manages and provides a clock to all other boards in the equipment. It also provides for inter-NE communication. The EFI board provides maintenance and management interfaces. The MON32 board detects the insertion loss between the board and the backplane and detects the single-wavelength optical power of optical signals in line directions. |
Fan areas |
2 fan tray assemblies (TMP1FAN) |
Lower portion: IU90 Upper portion: IU91 |
The fan tray assemblies are used to ventilate the equipment. |
Fiber-routing areas |
4 fiber troughs |
N/A |
Fiber patch cords connecting to boards are routed to the left or right side of the equipment through the upper- and lower-side fiber troughs. |
Service board areas |
32 service boards |
Lower portion: IU1–IU16 Upper portion: IU17–IU32 |
Service boards need to be configured based on the service plan and all of them are installed in the two service board areas. |
Requirements for Inserting Service Boards in a Subrack
To ensure that service grooming is normal and fiber routing is convenient, service boards must be inserted into the subrack in accordance with certain requirements.
To insert service boards into the 9800 P32 subrack, the following requirements must be met:
- The sequence of installing optical tributary boards is D->C->B->A. That is, you can insert boards in the next area only after all slots of area D are fully inserted with boards.
- The sequence of installing optical line boards is A->B->C->D. That is, you can insert boards in the next area only after all slots of area A are fully inserted with boards.
When the preceding board installation sequence is met:
- Because there are a large number of optical fibers on the front panels of optical tributary boards, to facilitate future expansion using optical fibers, install the optical tributary boards from edge side to the middle in sequence. Example: During the installation in area D, if there are two OT3232 optical tributary boards, you need to select the area with the most convenient fiber routing according to the actual environment. Assume that the left-side area D is selected. Preferentially use slots IU1 and IU2, and then use slots IU3 and IU4 in sequence. Assume that the right-side area D is selected. Preferentially use slots IU16 and IU15. Other areas comply with the same rules.
- Because there are a few optical fibers on the front panels of optical line boards, install the optical line boards in each area from left to right. Example: If there are three optical line boards, preferentially install the three optical line boards in slots IU5-IU7 of area A from left to right in sequence. If new optical line boards need to be installed, install them from left to right in sequence until area A is full. Other areas comply with the same rules.
NOTE:
Slots D and C on the left and right sides are the same. There is no requirement on the sequence of installing boards in the two slots.
Figure 2. Slots for installing service boards in the OptiX OSN 9800 P32 subrack
NOTE:
The cable trough in the middle of the subrack is printed with the requirements for inserting service boards.
Get More Information
Do you have any question about the Huawei OptiX OSN 9800 P32?
Contact us now via Live Chat or info@itg-spb.ru.
Huawei OptiX OSN 9800 P32 Specifications |
||
Subrack dimensions (mm) |
1390 (H) x 496 (W) x 315 (D) (without cabinet) |
|
Suitable cabinet |
ETSI 300 cabinets, such as A63B |
|
Number of slots for service boards |
32 |
|
Switching capability |
Optical |
1 to 32-degree reconfigurable optical add/drop multiplexer (ROADM) |
Electrical |
N/A |
|
Max. number of wavelengths |
Fixed grid: 96 wavelengths @50 GHz grid Flex grid: The maximum number of wavelengths is related to the width of the flex channel. |
|
Channel spacing |
Fixed grid: 50 GHz grid/100 GHz grid Flex grid: Supports channel spacing designs, and the minimum can be set to 6.25 GHz. |
|
Center wavelength range |
DWDM system: 1529.16 nm to 1567.13 nm (extend C-band, ITU-T G.694.1) |
|
Topology |
Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, and mesh |
|
Redundancy and protection |
Network level protection |
Optical line protection |
Equipment level protection |
Power redundancy, fan redundancy, communication control and clock processing unit redundancy |
|
Optical power management |
IPA |
|
Easy O&M |
Optical Doctor System (OD), Fiber Doctor System (FD) |
|
Synchronization |
Synchronous Ethernet clock IEEE 1588v2 ITU-T G.8275.1 |
|
Power Supply |
Nominal working voltage: -48V DC/-60V DC Working voltage range: -48 V DC: -40 V to -57.6 V -60 V DC: -48 V to -72 V |
|
Operation environment |
Subrack temperature: Long-term operation: 5°C (41°F) to 40°C (104°F) Short-term operationba: -5°C (23°F) to 45°C (113°F) Relative humidity: Long-term operation: 5% to 85% Short-term operationa: 5% to 90% |
|
Mean Time To Repair (MTTR) |
4 hours |
|
Mean Time Between Failure (MTBF) |
64.37 years |
|
a: Short-term operation means that the continuous operating time does not exceed 96 hours and the accumulated time per year does not exceed 15 days. |
Характеристики | |
1 to 32-degree reconfigurable optical add/drop multiplexer (ROAD | Electrical |
DWDM system: 1529.16 nm to 1567.13 nm (extend C-band, ITU-T G.69 | Topology |
Easy O&M | Optical Doctor System (OD), Fiber Doctor System (FD) |
Equipment level protection | Power redundancy, fan redundancy, communication control and clock processing unit redundancy |
Fixed grid: 50 GHz grid/100 GHz gridFlex grid: Supports channel | Center wavelength range |
Fixed grid: 96 wavelengths @50 GHz gridFlex grid: The maximum nu | Channel spacing |
Mean time between failure (MTBF) | 64.37 years |
Mean time to repair (MTTR) | 4 hours |
N/A | Max. number of wavelengths |
Network level protection | Optical line protection |
Number of Slots for Service Boards | 32 |
Operation environment | Subrack temperature:Long-term operation: 5°C (41°F) to 40°C (104°F)Short-term operationba: -5°C (23°F) to 45°C (113°F)Relative humidity:Long-term operation: 5% to 85%Short-term operationa: 5% to 90% |
Optical power management | IPA |
Point-to-point, chain, star, ring, ring-with-chain, tangent ring | Redundancy and protection |
Power supply | Nominal working voltage:-48V DC/-60V DCWorking voltage range:-48 V DC: -40 V to -57.6 V-60 V DC: -48 V to -72 V |
Subrack dimensions (mm) | 1390 (H) x 496 (W) x 315 (D) (without cabinet) |
Suitable cabinet | ETSI 300 cabinets, such as A63B |
Switching capability | Optical |
Synchronization | Synchronous Ethernet clockIEEE 1588v2ITU-T G.8275.1 |