The H801SCUN board is a super control unit board. It is the core of the system control and service switching and aggregation. The H801SCUN board can also function as the management and control core of the integrated network management system (NMS). It communicates with service boards about the key management and control information through the master/slave serial port and inband GE/10GE channel. In this manner, the H801SCUN board configures, manages, and controls the device, and also implements the simple route protocol functions.
Quick Spec
Table 1 shows the quick spec.
Board |
H801SCUN |
Access Service |
Optical and copper |
Daughter Board |
H801FLBA H801CKMC H801CKMD H801M2XA |
Load sharing |
Yes (supported in V800R011C00 and later versions) |
Ethernet synchronization |
No |
Temperature querying and high temperature alarming |
Yes |
Built-in 2GB CF card |
No |
Centric Management for GE Remote Extended Subracks |
Yes |
D-CCAP |
No |
Product Details
All MA5600T SCU boards support the functions as below:
- System control and management unit
- Active/standby switchover
- Local and remote maintenance through maintenance serial port CON or maintenance Ethernet port ETH
- Environmental monitoring through environment monitoring serial port ESC
Compare to Similar Item
Table 2 shows the comparison.
Board |
H801SCUN |
H801SCUB |
Access Service |
Optical and copper |
Copper |
Daughter Board |
H801FLBA H801CKMC H801CKMD H801M2XA |
H801FLBA H801CKMC H801CKMD |
Load sharing |
Yes (supported in V800R011C00 and later versions) |
No |
Ethernet synchronization |
No |
No |
Temperature querying and high temperature alarming |
Yes |
Yes |
Built-in 2GB CF card |
No |
No |
Centric Management for GE Remote Extended Subracks |
Yes |
No |
D-CCAP |
No |
No |
Get More Information
Do you have any question about the H801SCUN?
Contact us now via Live Chat or info@itg-spb.ru.
H801SCUN Specification |
|
Access Service |
Optical and copper |
Daughter Board |
H801FLBA H801CKMC H801CKMD H801M2XA |
Load sharing |
Yes (supported in V800R011C00 and later versions) |
Ethernet synchronization |
No |
Temperature querying and high temperature alarming |
Yes |
Built-in 2GB CF card |
No |
Centric Management for GE Remote Extended Subracks |
Yes |
D-CCAP |
No |
Panel ports |
4 GE ports |
Internal interfaces |
|
Channel to the service board |
16 GE/10GE channels |
Channel to the GIU board |
Providing two GE/10GE channels for each upstream boards |
Channel to the standby control board |
Providing two 10GE channels for load sharing with the standby H801SCUN board (supported in V800R011C00 and later versions) |
Характеристики | |
16 GE/10GE channels | Channel to the GIU board |
Access Service | Optical and copper |
Built-in 2GB CF card | No |
Centric Management for GE Remote Extended Subracks | Yes |
D-CCAP | No |
Daughter Board | H801FLBAH801CKMCH801CKMDH801M2XA |
Ethernet synchronization | No |
Internal interfaces | Channel to the service board |
Load sharing | Yes (supported in V800R011C00 and later versions) |
Panel ports | 4 GE ports |
Providing two GE/10GE channels for each upstream boards | Channel to the standby control board |