+7 (812) 309 34 73. Договоримся!
Общая информация (LE0KS9306)
S9306 is one of the S9300 series switches(S9300 for short). And the LE0KS9306 is the Huawei S9306 Assembly Chassis. The S9300 series switches are next-generation high-end terabit routing switches, developed by Huawei and designed for multiservice convergence. The S9300 design is based on Huawei's intelligent multilayer switching technology to provide high-definition video services, large-capacity wireless networks, elastic cloud computing, IPv6-capable hardware, and integrated security, in addition to high-performance L2/L3 switching services. The S9300 is a highly extensible and reliable platform, integrating switching and routing functions to facilitate end-to-end integrated networks. It is widely used in WANs, MANs, campus networks, and data centers to help enterprises build application-oriented networks.
Быстрые спецификацииs
Figure 1 shows the S9306 chassis appearance. LE0KS9306 is one of the S9306 chassis, including no cards, modulesunits.
Таблица 1 показывает Быстрые спецификацииs.
Product Code |
LE0KS9306 |
Packet forwarding rate |
2880Mpps |
Switching Capacity |
3.84Tbps |
Service slot quantity |
6 |
MPU Slots |
2 |
LPU slots |
6 |
Fan slots |
2 |
System power supply slots |
4 |
PoE power supply slots |
4 |
Chassis power supply capability (without PoE power supply) |
1600W |
Chassis PoE power supply capability |
8800W |
Maximum power consumption (fully loaded, no PoE power supply) |
2200 W |
Working voltage |
DC: –38.4V to –72V AC: 90V to 290V |
Dimensions (W x D x H, excluding rack-mounting brackets) |
With cable management frames: 442 mm x 585 mm x 441.7 mm (17.4 in. x 23.0 in. x 17.39 in. (10 U)) Without cable management frames: 442 mm x 489 mm x 441.7 mm (17.4 in. x 19.3 in. x 17.39 in. (10 U)) |
Weight (empty/fully loaded) |
15 kg/42 kg (33.1 lb/92.6 lb) |
Детали продукта
Figure 2 shows the S9306 chassis structure (front view).
Note:
? |
Six service cards, including:
|
? |
Two MPUs |
? |
A pair of mounting brackets |
? |
Four power modules |
? |
Two LE0DCMUA0000-Centralized Monitoring Unit |
? |
Four PoE power modules |
? |
Ground screw |
? |
Front ESD jack |
? |
Cable management frames |
Figure 3 shows S9306 chassis structure (rear view).
Note:
? |
Two Fan Module |
? |
Rear ESD jack |
? |
Air filter |
? |
A pair of removable handles |
The Modules, Cards
Table 2 shows the recommended elements for the LE0KS9306.
Model |
Description |
FE-SFP optical transceiver |
|
SFP-FE-SX-MM1310 |
Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC) |
eSFP-FE-LX-SM1310 |
Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC) |
S-SFP-FE-LH40-SM1310 |
Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC) |
GE-SFP optical transceiver |
|
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC) |
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC) |
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC) |
10G-SFP+ optical transceiver |
|
SFP-10G-USR |
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC) |
OMXD30000 |
Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC) |
OSX010000 |
Optical Transceiver, SFP+, 10G, Single-mode Module(1310nm, 10km, LC) |
40GE CFP optical transceiver |
|
CFP-40G-SR4 |
High Speed Transceiver CFP-40G-SR4,CFP,40G,Multimode Module(850nm,4*10G,0.1km,MPO) |
CFP-40G-LR4 |
High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,10km,stright LC) |
CFP-40G-ER4 |
High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,40km,stright LC) |
40GE QSFP+ optical transceiver |
|
QSFP-40G-eSR4 |
40GBase-eSR4 Optical Transceiver,QSFP+,40G,Multi-mode (850nm,0.3km,MPO)(Connect to four SFP+ Optical Transceiver) |
QSFP-40G-ER4 |
40GBase-ER4 Optical Transceiver,QSFP+,40G,Single-mode Module (1310nm,40km,LC) |
100GE CFP optical transceiver |
|
CFP-100G-SR10
|
High Speed Transceiver,CFP,100G,Multimode Module(850nm,10*10G,0.1km,MPO) |
CFP-100G-LR4 |
CFP, 100G, Single-mode Module(1310nm band,4*25G,10km,stright LC) |
CFP-100G-ER4
|
High Speed Transceiver,CFP,100G,Single-mode Module(1310nm band,4*25G,40km,stright LC) |
GE copper transceiver |
|
SFP-1000BaseT |
Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45) |
100GE interface card |
|
ET1D2C02FEE0 |
2-Port 100GBASE-X Interface Card(EE,CFP) ET1D2C02FEE0series) |
10GE interface card |
|
ET1D2X32SSC0 |
32-Port 10GBASE-X Interface Card(SC,SFP+) |
ET1D2X12SSA0 |
12-Port 10GBASE-X Interface Card(SA,SFP+) |
40GE interface card |
|
ET1D2L08QSC0
|
8-Port 40GBASE-X Interface Card(SC,QSFP+) |
ET1D2L02QSC0 |
2-Port 40GBASE-X Interface Card(SC,QSFP+) |
Centralized monitoring unit |
|
EH1D200CMU00 |
Centralized Monitoring Board |
Cluster switching system unit |
|
EH1D2VS08000 |
8-Port 10G Cluster Switching System Service Unit (SFP+) |
Firewall module |
|
ET1D2FW00S02 |
NGFW Module C,with HW General Security Platform Software |
ET1D2FW00S01 |
NGFW Module B,with HW General Security Platform Software |
GE/10GE interface card |
|
ET1D2S08SX1E |
8-Port 10GBASE-X and 8-Port 100/1000BASE-X and 8-Port 10/100/1000BASE-T Combo Interface Card(X1E,RJ45/SFP/SFP+) |
ET1D2S04SX1E |
4-Port 10GBASE-X and 24-Port 100/1000BASE-X and 8-Port 10/100/1000BASE-T Combo Interface Card(X1E,RJ45/SFP/SFP+) |
Intrusion prevention system module |
|
ET1D2IPS0S00 |
IPS Module A,with HW General Security Platform Software |
Main processing unit |
|
ET1D2MPUA000 |
S12708/S12712,Main Processing Unit A(Optional clock) |
Switch fabric unit |
|
ET1D2SFUD000 |
S12708/S12712,Switch Fabric Unit D |
ET1D2SFUA000 |
S12708/S12712,Switch Fabric Unit A |
Wireless access controller unit |
|
ACU2 |
WLAN ACU2 Access Controller Unit(128 AP Control Resource Included) |
GE interface card |
|
ET1D2T36SEA0 |
36-Port 10/100/1000BASE-T and 12-Port 100/1000BASE-X Interface Card(EA,RJ45/SFP) |
ET1D2G48SX1E |
48-Port 100/1000BASE-X Interface Card(X1E,SFP) |
Сравнить похожие товары
Table 3 shows the comparison of LE0KS9306 and EH1BS9712E00.
Product Code |
LE0KS9306 |
EH1BS9712E00 |
Switching Capacity |
2 T/5.12 T |
8.64 Tbit/s18.56 Tbit/s |
MPU Slots |
2 |
2 |
LPU slots |
6 |
12 |
Service Slots |
6 |
12 |
Fan slots |
2 |
4 |
Power slots |
4 |
6 |
Maximum power consumption (fully loaded) |
2200 W |
4500 W |
Что бы получить больше информации
У вас есть какие-либо вопросы о LE0KS9306?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
PoE | ·Power input: Versions earlier than V200R006C00 support only AC power supply. V200R006C00 and later versions support both AC power supply and DC power supply (only 2200 W DC power modules). ·PoE power module backup: no backup, 3+1 backup, or 2+2 backup ·Maximum output power: 8800 W |
Switching capacity | 3.84Tbps |
QoS | Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p fields ACL, CAR, and actions including Remark and Schedule Queuing algorithms, such as SP, WRR, DRR, SP+WRR, and SP+DRR Congestion avoidance mechanisms, including WRED and tail drop H-QOS Traffic shaping |
Multicast | IGMPv1/v2/v3 and IGMP v1/v2/v3 snooping PIM-DM, PIM-SM, and PIM-SSM MSDP and MBGP Prompt leave Multicast traffic control Multicast querier Multicast protocol packet suppression Multicast CAC Multicast ACL |
Reliability and availability | MTBF: 24.2 years MTTR: 52 minutes Availability: 0.9999959 |
MAC address | MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses MAC address limiting based on ports and VLANs |
VLAN | Access, trunk, and hybrid Default VLAN VLAN switching QinQ and selective QinQ MAC-based VLAN assignment |
IP routing | IPv4 dynamic routing protocols, such as RIP, OSPF, IS-IS, and BGP IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+ |
Packet forwarding rate | 2880Mpps |
Reliability | LACP and inter-chassis E-Trunk VRRP and BFD for VRRP BFD for BGP/IS-IS/OSPF/static route NSF and GR for BGP/IS-IS/OSPF/LDP TE FRR and IP FRR Ethernet OAM in compliance with IEEE 802.3ah and 802.1ag (hardware-level) ITU-Y.1731 DLDP |
Service slot quantity | 6 |
User management | Unified user management 802.1x, MAC, and Portal authentications Charging based on traffic volume and online duration User authorization based on user groups, domains, and time ranges |
Configuration and maintenance | iPCA, monitor network quality for any service flow at any network node, at any time, and without extra costs Terminal access services such as console port login, Telnet, and SSH Network management protocols, such as SNMPv1/v2/v3 File uploading and downloading through FTP and TFTP BootROM upgrade and remote in-service upgrade Hot patches User operation logs |
Security and user management | 802.1x authentication and Portal authentication NAC RADIUS and HWTACACS authentication for login users Command line authority control based on user levels (unauthorized users cannot use commands) Defense against DoS attacks, TCP SYN Flood attacks, UDP Flood attacks, broadcast storms, and traffic flooding attacks 1K CPU queues Ping and traceroute RMON |
Security protection | Firewall Network Address Translation (NAT) IPSec, SSL VPN Intrusion Protection System (IPS) Load balancing Analog Digital Conversion (ADC) |
Energy saving | Energy Efficient Ethernet (802.3az) |
LPU slots | 6 |
STP/ERPS | STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) BPDU protection, root protection, and loop protection BPDU tunnel G.8032 Ethernet Ring Protection Switching (ERPS) |
MPU slots | 2 |
Fan slots | 2 |
System power supply slots | 4 |
PoE power supply slots | 4 |
Maximum port density | ·V100R006C00 and V200R001C00: 288xFE, 288xGE, 240x10GE ·V200R002C00 to V200R007C00: 288xFE, 288xGE, 240x10GE, 12x40GE ·V200R008C00 to V200R009C00: 288xFE, 288xGE, 240x10GE, 12x40GE, 12x100GE ·V200R010C00 and later versions: 288xFE, 288xGE, 288x10GE, 48x40GE, 24x100GE |
Installation | In an N66E or N68E cabinet, one or two chassis in a cabinet |
CSS | CSS card or service port clustering |
Maximum power consumption (fully loaded, no PoE power supply) | 2200 W |
Power specifications | ·DC input voltage Rated voltage: -48 V DC/-60 V DC Maximum voltage range: 1600 W/2400 W DC power module: -38.4 V DC to -72 V DC 2200 W DC power module: -40 V DC to -72 V DC ·AC input voltage Rated voltage: 110 V AC/220 V AC, 50/60 Hz Maximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input voltage is in the range of 90 V AC to 175 V AC.) |
Dimensions (W x D x H, excluding rack-mounting brackets) | ·With cable management frames: 442 mm x 585 mm x 441.7 mm (17.4 in. x 23.0 in. x 17.39 in. (10 U)) ·Without cable management frames: 442 mm x 489 mm x 441.7 mm (17.4 in. x 19.3 in. x 17.39 in. (10 U)) |
Weight (empty/fully loaded) | 15 kg/42 kg (33.1 lb/92.6 lb) |
Environment parameters | ·Operating temperature and altitude: -60 m to +1800 m (197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F) 1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m (722 ft.). 4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F) ·Operating relative humidity: 5% RH to 95% RH (noncondensing) ·Storage temperature: -40°C to +70°C (-40°F to +158°F) ·Storage altitude: < 5000 m (16404 ft.) ·Storage relative humidity: 5% RH to 95% RH (noncondensing) |
Noise at normal temperature (acoustic power) | 72 dBA |
EMC compliance | CISPR22 Class A CISPR24 EN55022 Class A EN50024 ETSI EN 300 386 Class A ICES 003 Class A AS/NZS CISPR22 Class A VCCI Class A IEC61000-6-2 IEC61000-6-4 IEC61000-4-2 ITU-T K 20 ITU-T K 21 ITU-T K 44 CNS13438 CLASS A KN 22 CLASS A |
Environmental standards compliance | RoHS REACH WEEE |
Safety standards compliance | IEC 60950-1 EN 60950-1 UL 60950-1 CSA C22.2 No 60950-1 AS/NZS 60950.1 BS EN 60950-1 |
MPLS | Basic MPLS functions MPLS OAM MPLS TE MPLS VPN/VLL/VPLS |
Теги: LE0KS9306 Huawei