+7 (812) 309 34 73. Договоримся!
Общая информация (S5720-32X-EI-24S-DC)
Huawei S5720-32X-EI-24S-DC is one of the S5720-EI switches. Huawei’s S5720-EI Series Gigabit Switches provide resilient, energy-efficient GE ports for access switching in data centers, and aggregation switching in enterprise campus networks. Performance enhancements include advanced processing hardware, 10 Gbit/s uplink ports, and large MAC address and routing tables; Super Virtual Fabric (SVF) support enables intelligent virtualization, iStack clustering, and operation in N + 1 backup mode for simplified O&M and high availability. Mature IPv6 features ensure smooth migration to next-generation IP networking.
Быстрые спецификацииs
На рисунке 1 показан внешний вид S5720-32X-EI-24S-DC.
Таблица 1 показывает Быстрые спецификацииs.
Product Code |
S5720-32X-EI-24S-DC |
Switching Capacity |
598 Gbit/s |
Forwarding Performance |
102 Mpps |
Fixed Interfaces |
24 x 100/1,000 Base-X SFP ports, 4 x 10/100/1,000 Base-T Ethernet ports, and 4 x 10G SFP+ ports |
Power Supply |
DC power supply, supporting RPS, power socket on the front panel |
Memory |
2 GB |
Flash |
340 MB |
Dimensions (W x D x H) |
442.0 mm x 220.0 mm x 43.6 mm (17.4 in. x 8.7 in. x 1.72 in.) |
Weight |
≤ 8 kg (17.64 lb) |
Детали продукта
На рисунке 2 показана передняя панель S5720-32X-EI-24S-DC.
Note:
? |
Twenty-four 100/1000BASE-X ports |
? |
Four 10/100/1000BASE-T ports |
? |
Four 10GE SFP+ ports |
? |
One mini USB port |
? |
One console port |
? |
One ETH management port |
? |
One USB port |
? |
DC power terminal |
?·One console port is used with a console cable. The console cable is not delivered with the switch and needs to be separately purchased if needed.
На рисунке 3 показана задняя панель S5720-32X-EI-24S-DC.
Note:
? |
Ground screw |
? |
Two QSFP+ stack optical ports |
? |
RPS socket |
The Modules
Table 2 shows the recommended elements for the S5720-32X-EI-24S-DC.
Model |
Description |
FE-SFP Optical Transceiver |
|
SFP-FE-SX-MM1310 |
Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC) |
eSFP-FE-LX-SM1310 |
Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC) |
S-SFP-FE-LH40-SM1310 |
Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC) |
GE-SFP Optical Transceiver |
|
eSFP-GE-SX-MM850 |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC) |
SFP-GE-LX-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC) |
S-SFP-GE-LH40-SM1310 |
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC) |
S-SFP-GE-LH40-SM1550 |
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC) |
10G-SFP+ Optical Transceiver |
|
SFP-10G-USR |
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC) |
OMXD30000 |
Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC) |
OSX010000 |
Optical Transceiver, SFP+, 10G, Single-mode Module(1310nm, 10km, LC) |
GE Copper Transceiver |
|
SFP-1000BaseT |
Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45) |
Сравнить похожие товары
Table 3 shows the comparison of S5720-32X-EI-24S-DC and S5720-56PC-EI-AC.
Product Code |
S5720-32X-EI-24S-DC |
S5720-56PC-EI-AC |
Switching Capacity |
598 Gbit/s |
598 Gbit/s |
Forwarding Performance |
102 Mpps |
108 Mpps |
Extended Slot |
No |
One extended slot |
Fixed Interfaces |
24 x 100/1,000 Base-X SFP ports, 4 x 10/100/1,000 Base-T Ethernet ports, and 4 x 10G SFP+ ports |
48 x 10/100/1,000 Base-T Ethernet ports and 4 x 1,000 Base-X SFP ports |
Comparison between LI, SI, EI and HI
Huawei S5720 Series Enterprise Switches provides LI (Lite), SI (Standard), EI (Enhanced) and HI (Hyper) models for users. There are some differences among these four versions.
Click this PDF to know more.
Comparison of Huawei S5720-LI, SI, EI and HI Series Switches.pdf.
Что бы получить больше информации
У вас есть какие-либо вопросы о S5720-32X-EI-24S-DC?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
Dimensions (W x D x H) | 442 mm x 220 mm x 43.6 mm |
Security Features | Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, interface number, and VLAN ID of a user Port isolation, port security, and sticky MAC MAC Forced Forwarding (MFF) Blackhole MAC address entries Limit on the number of learned MAC addresses IEEE 802.1x authentication and the limit on the number of users on an interface AAA authentication, RADIUS authentication, HWTACACS+ authentication, and NAC SSH v2.0 Hypertext Transfer Protocol Secure (HTTPS) CPU defense Blacklist and whitelist MACSec |
VLANs | 4K VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports 1:1 and N:1 VLAN mapping VLAN-based transparent transmission of protocol packets |
Input Voltage | DC: Rated voltage range: –48V to –60V Maximum voltage range: –36V to –72V |
Switching Capacity | 598 Gbit/s |
Forwarding Performance | 102 Mpps |
Management and Maintenance | iStack Virtual cable test SNMPv1/v2c/v3 RMON/RMON2 Web-based network management system System logs and multi-level alarms sFlow LLDP/LLDP-MED Secure Copy Protocol (SCP), TFTP, FTP Store dual software images and configuration files 802.3az Energy Efficient Ethernet (EEE) |
Interoperability | VLAN-based Spanning Tree (working with PVST/PVST+/RPVST) Link-type Negotiation Protocol (LNP), similar to the Dynamic Trunking Protocol (DTP) VLAN Central Management Protocol (VCMP), similar to the VLAN Trunk Protocol (VTP) |
Operating Environment | Operating temperature: Zero to 1,800m altitude: 0°C to 45°C 1,800m to 5,000m altitude: Operating temperature reduces by 1°C for every altitude increase of 220m. Relative humidity: 5% to 95% (non-condensing) |
Fixed Ports | 24 x 100/1,000 Base-X SFP, 4 x 10/100/1,000 Base-T, 4 x 10 Gig SFP+ |
MAC Address Table | 64k |
Reliability | Ethernet OAM (IEEE 802.3ah and 802.1ag) ITU-Y.1731 BFD for BGP/IS-IS/OSPF/static route |
IP Routing | Static routing, RIPv1/v2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, and policy-based routing |
IPv6 Features | Neighbor Discovery (ND) Path Maximum Transmission Unit (PMTU) IPv6 Ping, IPv6 Tracert, and IPv6 Telnet 6to4 tunnel, ISATAP tunnel, and manually configured tunnel ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types Multicast Listener Discovery (MLD) v1/v2 snooping |
QoS/ACL | Inbound and outbound traffic rate limiting on a port Packet redirection Broadcast storm control Port-based traffic policing and two-rate and three-color CAR Eight queues per port, Weighted Round Robin (WRR), Deficit Round Robin (DRR) Strict Priority (SP), WRR + SP, and DRR + SP queue scheduling algorithms Weighted Random Early Detection (WRED) Re-marking of the 802.1p priority and DSCP value of packets Packet filtering based on Layer 2 to Layer 4 information, including source MAC addresses, destination MAC addresses, source IP addresses, destination IP addresses, TCP/UCD source/destination ports, protocol types, and VLAN IDs Per queue rate limiting and interface traffic shaping 1:1, N:1, N:4 port mirroring VLAN mirroring |
Access Security | DHCP Relay DHCP Server DHCP Snooping DHCP Client DHCP Security |
DRAM and Flash Memory | SDRAM: 2 GB Flash: 340 MB |
Extended Slot | NA |
DRAM and Flash | SDRAM: 2 GB Flash: 340 MB |
Jumbo Frame | 12K |
Multicast Forwarding | IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load splitting among trunk member ports Controllable multicast Layer 2 multicast control Port-based multicast traffic statistics collection IGMPv1/v2/v3, Protocol Independent Multicast Sparse Mode (PIM-SM), and Protocol Independent Multicast Dense Mode (PIM-DM), and Protocol Independent Multicast Source-Specific Multicast (PIM-SSM) Multicast Source Discovery Protocol (MSDP) |
Port Aggregation | LACP Up to 128 trunk groups Up to 8 member interfaces in each trunk group |
Surge Protection | Surge protection capability of service ports: 6 kV |
Front Power Input | Yes |
Typical Power Consumption | 55.5W |
MPLS | MPLS L3VPN MPLS L2VPN (VPWS/VPLS) MPLS-TE MPLS QoS |
Ring Protection | RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover Smart Ethernet Protection (SEP), G.8032 Ethernet Ring Protection Switching (ERPS) STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) BPDU protection, root protection, and loop protection BPDU tunnel |