+7 (812) 309 34 73. Договоримся!
Общая информация (9000-P36)
Huawei OceanStor 9000 P36 (AC, 4U 36 Disks, 48G Mem, SPE31M0138) 9000-P36.
Быстрые спецификацииs
На рисунке 1 показан внешний вид 9000-P36.
Таблица 1 показывает Быстрые спецификацииs.
Product Code |
9000-P36 |
System architecture |
Fully symmetrical distributed architecture |
Number of nodes |
3 to 288 |
CPUs per node |
2 x Intel E5 series |
NVDIMM |
2 GB NVDIMM |
Cache per node |
Standard configuration: 48 GB, scalable to 192 GB |
Data disk type |
3.5-inch SSD, SATA disks, and NL-SAS disks |
Front-end network type |
10GE, InfiniBand, and 1GE |
Internal network type |
10GE and InfiniBand |
Dimensions (H x W x D) |
Node :4 U, 175 mm x 446 mm x 582 mm (3.39 in. x 17.56 in. x 22.91 in.) Cabinet: Maximum size: 2000 mm x 600 mm x 1200 mm (78.4 in. x 23.62 in. x 47.24 in.) |
Детали продукта
Figure 2 shows the front view of a P36 node.
Note:
? |
System power indicator/power button |
? |
System alarm indicator |
? |
System location indicator |
? |
USB port |
? |
Disk activity indicator |
? |
Disk alarm/location indicator |
Figure 3 shows the rear panel of a P36 node.
Note:
? |
Power module handle |
? |
Power status/alarm indicator |
? |
Power socket |
? |
PCIe expansion slot |
? |
SAS HBA |
? |
GE network port |
? |
IPMI management network port |
? |
USB port |
? |
Serial port |
? |
VGA port |
? |
System alarm indicator |
? |
System location indicator |
? |
LNK indicator of the IPMI management network port |
? |
ACT indicator of the IPMI management network port |
? |
ACT indicator of the GE network port |
? |
LNK indicator of the GE network port |
? |
Disk activity indicator |
? |
Disk alarm/location indicator |
? |
Indicator of the 10GE SFP+ Ethernet optical port |
? |
10GE SFP+ Ethernet optical port |
Сравнить похожие товары
В таблице 2 показано сравнение of 9000-C36B2-4T and 9000-P36.
Model |
9000-P36 |
9000-C36B2-4T |
Product Part Number |
02350FUS |
02350GDT |
Description |
P36(AC. 4U 36 Disks. 48G Mem. SPE31M0138) |
C36(AC, 4U, 32G Mem, Front end 4*GE, Back end 2*10GE, 36*4TB SATA cold datalow load special, SPE31M0138) Pending |
Что бы получить больше информации
У вас есть какие-либо вопросы о 9000-P36?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
Operating temperature | 5 C to 35 C (41 F to 95 F) when the altitude ranges from –60 m to +1,800 m (–196.85 ft to +5,905.44 ft) When the altitude is higher than 1,800 m (5,905.44 ft) but lower than or equal to 3,000 m (9,842.4 ft), the ambient temperature drops by 0.6 C (1.08 F) for every 100-m (328.08-ft) increment in altitude. |
Software | Dynamic storage tiering (InfoTier) Automatic load balancing of client connections (InfoEqualizer) Space quota management (InfoAllocator) Snapshot (InfoStamper) WORM (InfoLocker) Remote replication (InfoReplicator) Surveillance video and imagery restoration (SecureVideo) |
Dimensions (H x W x D) | Node :4 U, 175 mm x 446 mm x 582 mm (3.39 in. x 17.56 in. x 22.91 in.) |
Power supply | 200 V AC to 240 V AC |
Weight | Fully loaded with 3.5-inch disks: 70 kg (154 lb.) |
Operating humidity | 20% RH to 80% RH |
System architecture | Fully symmetrical distributed architecture |
Number of nodes | 3 to 288 |
CPUs per node | 2 x Intel E5 series |
NVDIMM | 2 GB NVDIMM |
Cache per node | Standard configuration: 48 GB, scalable to 192 GB |
Data disk type | 3.5-inch SSD, SATA disks, and NL-SAS disks |
Number of disks per node | Standard configuration: 1 x 3.5-inch 400 GB SSD + 35 x 3.5-inch 2 TB/4 TB/6 TB/8 TB/10 TB SATA or 2 TB/4 TB NL-SAS (The SSD/ HDD configuration ratio can be adjusted based on actual performance requirements.) |
Front-end network type | 10GE, InfiniBand, and 1GE |
Internal network type | 10GE and InfiniBand |
Application Scenarios | Large-capacity and highbandwidth |
Data protection level | N+1, N+2, N+3, N+4 (Data is still usable even if 4 nodes failed.) |
File system | OceanStor DFS, which supports the global namespace and can be dynamically expanded up to 100 PB |
Value-added object storage feature | Object-level deduplication Multi-tenant HTTPs Encrypted transmission |
Thin provisioning | Support for thin provisioning, which does not need to be configured |
Data self-healing | Automatic, concurrent, and quick data restoration, with maximum restoration speed at 1 TB/hour |
System expansion | One-click online expansion, with less than 60 seconds needed for expansion of a single node |
Global cache | Up to 55 TB of global cache |
Operating system | Windows, Linux, UNIX, and Mac OS |
Supported protocols | NFS, CIFS, FTP, HDFS, S3/Swift, NDMP, NIS, Microsoft Active Directory, and LDAP |
System management | Support for users with different management rights, and domain- and rights-based user management Alarm notification by email, SMS, SNMP, and Syslog |
Bad disk detection | Automatic bad disk detection and alarm notification as well as batch replacement of bad disks, avoiding the need for immediate replacement while freeing up maintenance personnel to handle more pressing tasks. |
Typical power | 580 W |
Теги: 9000-P36 Huawei