+7 (812) 309 34 73. Договоримся!
Общая информация (Huawei RH1288 V2 Rack Server)
Huawei RH1288 V2 rack server is designed for compute intensive and cloud applications. This high-performance 1U rack server supports 2*Intel Xeon E5-2600Intel Xeon E5-2600 V2 series processors, 24*DDR3 RDIMMs/LRDIMMS slots to support up to 768GB memory capacity, 8*2.5” SAS/SATA HDDsSSDs4*3.5” SASSATA HDDSs. This server supports twofour GE portstwo 10 GE ports without occupying any PCIe slots, improving network availability. Moreover, Dynamic energy-saving and power-capping technologies limit server power consumption to a preset threshold, improving overall energy efficiency.
Быстрые спецификацииs
На рисунке 1 показан внешний вид Huawei RH1288 V2 Rack Server. The RH1288 V2 has two models:
Figure 1-1 shows the RH1288 V2-8S that supports eight 2.5-inch SAS HDDs, SATA HDDs,solid-state drives (SSDs).
Figure 1-2 shows the RH1288 V2-4L that supports four 3.5-inch SASSATA HDDs.
Таблица 1 показывает Быстрые спецификацииs.
Product |
Huawei RH1288 V2 Rack Server |
Processors |
Onetwo Intel Xeon E5-2600E5-2600 v2 series processors |
Memory |
24 DDR3 RDIMMs/LRDIMMs |
Internal Storage |
Hard disk configurations: |
RAID Support |
? RAID 0, 1, 10, 5, 50, 6,60 ? Supercapacitor ? RAID state migration, configuration memory, self-diagnosis, and web-based remote configuration |
LOM Network Ports |
Network configuration: twofour GE portstwo 10 GE ports |
PCIe Expansion |
Up to 3 PCIe slots |
Fan Modules |
Seven hot-swappable fan modules in N+1 redundancy mode |
PSUs |
2 hot-swappable PSUs in 1+1 redundancy mode |
Management |
Uses Huawei Hi1710 management chip and independent ports, supports standard management interfaces, such as SNMP and IPMI, and provides a GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring |
Operating Temperature |
5ºC to 35ºC (41ºF to 95ºF) |
Детали продукта
На рисунке 2 показана передняя панель Huawei RH1288 V2 Rack Server.
Figure 2-1 RH1288 V2-8S front view.
Note:
? |
|
UID button/indicator |
? |
Power button/indicator |
? |
|
USB port 1 |
? |
USB port 2 |
? |
|
Ethernet port indicator 1 |
? |
Ethernet port indicator 2 |
? |
|
HEALTHY indicator |
? |
VGA port |
? |
|
Disk |
? |
Captive screw |
? |
|
Hard disk fault indicator |
? |
Hard disk active indicator |
? |
|
Label (including ESN label) |
? |
(Optional) Built-in DVD-ROM driver (only for the RH1288 V2-8S) |
? |
|
Hard disk slot label |
? |
– |
Figure 2-2 RH1288 V2-4L front view.
? |
UID button/indicator |
? |
Power button/indicator |
? |
USB port 1 |
? |
USB port 2 |
? |
Ethernet port indicator 1 |
? |
Ethernet port indicator 2 |
? |
HEALTHY indicator |
? |
Disk |
? |
Captive screw |
? |
Hard disk fault indicator |
? |
Hard disk active indicator |
? |
Label (including ESN label) |
? |
Hard disk slot label |
? |
– |
На рисунке 3 показана задняя панель Huawei RH1288 V2 Rack Server.
Note:
? |
Connection status indicator |
? |
GE port 4 |
? |
Data transmission status indicator |
? |
GE port 3 |
? |
GE port 2 |
? |
GE port 1 |
? |
UID indicator |
? |
Management network port |
? |
USB port 2 |
? |
USB port 1 |
? |
VGA port |
? |
Serial port |
? |
Power socket of PSU 2 |
? |
PSU 2 indicator |
? |
PSU 2 |
? |
Power socket of PSU 1 |
? |
PSU 1 indicator |
? |
PSU 1 |
Сравнить похожие товары
Table 3 shows the comparison of Huawei RH1288 V2 Rack Server and Huawei RH1288A V2 Rack Server.
Product |
Huawei RH1288 V2 Rack Server |
Huawei RH 1288A V2 server |
Processors |
Onetwo Intel Xeon E5-2600E5-2600 v2 series processors |
12 Intel® Xeon® E5-2600 v2 series processors |
Memory |
24 DDR3 RDIMMs/LRDIMMs |
8 DDR3 RDIMMs/LRDIMMs |
Internal Storage |
Hard disk configurations: |
Hard disk configurations: |
LOM Network Ports |
Network configuration: twofour GE portstwo 10 GE ports |
Network configuration: 2 x GE electrical ports |
Fan Modules |
Seven hot-swappable fan modules in N+1 redundancy mode |
5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans |
Что бы получить больше информации
У вас есть какие-либо вопросы о Huawei RH1288 V2 Rack Server?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
Expansion slots | A maximum of three PCIe cards are supported: One standard PCIe slot of full height and full length One standard PCIe slot of half height and half length One non-standard PCIe slot for installing a RAID controller card The PCIe slots support the Huawei PCIe iNIC to improve the I/O bandwidth and throughput. The PCIe slots support one Huawei PCIe SSDs for search, cache, and download services to greatly improve the I/O performance. The PCIe expansion slots support the GPUs, such as Quadro 2000. |
Chipset | Intel® C602 chipset. |
Storage | NOTE: The total storage capacity of the server is different along with the single hard disk most large-capacity. The server supports two types of hard disk configurations: RH1288 V2-8S: supports eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs at the front. RH1288 V2-4L: supports four 3.5-inch SAS HDDs or SATA HDDs at the front. The following information lists the total storage capacity of eight 2.5-inch hard disks: SAS HDD: 7.2 TB SATA HDD: 8 TB SSD: 4.8 TB The following information lists the total storage capacity of four 3.5-inch hard disks: SAS HDD: 4 TB SATA HDD: 16 TB Hard disks are hot-swappable. SAS HDDs, SATA HDDs, and SSDs can be installed in one chassis. The server supports RAID 0, 1, 10, 5, 50, 6, and 60. It supports iBBU battery protection, RAID state migration, RAID configuration memory, self-diagnosis, and web-based configuration. The mainboard can be configured with an Serial Attached SCSI (SAS) card or an SAS RAID controller card (with the maximum 1 GB cache) for improving hard disk storage performance and protecting user data. RAID controller cards do not occupy standard PCIe slots, which ensures high scalability for the system. |
Humidity | Operating humidity: 8% to 90% RH (non-condensing) Storage humidity: 5% to 95% RH (non-condensing) The humidity change rate is smaller than 20% RH/h. Long-term storage humidity: 30% RH to 69% RH (non-condensing) |
Acoustic Noise | The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7999 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Idle: LWAd: 6.0 Bels LpAm: 43.0 dBA Operating: LWAd: 6.7 Bels LpAm: 50.1 dBA NOTE: The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature. |
Temperature | Operating temperature: 5°C to 35°C (41°F to 95°F) Storage temperature: -40°C to +65°C (-40°F to +149°F) The temperature change rate is smaller than 20°C (36°F)/h. Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F) |
Memory | Maximum number of double data rate 3 (DDR3) DIMMs: 24 Maximum memory capacity: 768 GB Capacity of a single DIMM: 4 GB, 8 GB, 16 GB, or 32 GB Memory speed: DDR3 800/1066/1333/1600/1866 MHz |
Altitude | 3000 m (9842 ft). When the altitude is higher than 900 m (2952.72 ft), the operating temperature decreases by 1°C (1.8°F) per 300 m (984.24 ft). |
Dimensions (H x W x D) | 43.6 mm (1 U) x 447 mm x 740 mm (1.72 in. x 17.60 in. x 29.92 in.) |
CPU | The server supports two Intel Xeon® E5-2600 (Sandy Bridge-EP) series CPUs. One or two CPUs of quad-core, six-core, or eight-core Highest CPU frequency: 3.3 GHz Maximum power consumption of each CPU: 135 W Maximum L3 cache of each CPU: 20 MB NOTE: The performance of the 135 W CPU may deteriorate when one fan fails. The server supports two Intel Xeon® E5-2600 v2 (Ivy Bridge-EP) series CPUs. One or two CPUs of 4/6/8/10/12 cores Highest CPU frequency: 3.5 GHz Maximum power consumption of each CPU: 130 W Maximum L3 cache of each CPU: 30 MB NOTE: The performance of the 130 W CPU may deteriorate when one fan fails. Two CPUs are connected through two QuickPath buses of full bandwidth. Each link provides a unidirectional transmission rate of up to 8.0 GT/s. |
Certification | Including CCC, CE, FCC, IC, VCCI, and C-tick |
I/O port | One onboard DVD-ROM/DVD-RW connector Five USB 2.0 ports: two on the front panel, two on the rear panel, and one on the mainboard One USB flash port on the mainboard One VGA port on the front panel for the RH1288 V2-8S and none for the RH1288 V2-4L; one VGA port on the rear panel for either server One RS232 port on the rear panel One RJ45 management port on the rear panel |
Network port | Four types of NICs are supported, providing the following network ports: Two GE electrical ports, supporting Network Controller Sideband Interface (NCSI), Wake on LAN (WOL), Preboot eXecution Environment (PXE). Four GE electrical ports, supporting NCSI, WOL, PXE. Two 10GE optical ports, supporting NCSI, PXE. Two 10GE electrical ports, supporting NCSI, WOL, PXE. |
Rated power | The rated power for compatible PSUs: 460 W 750 W 800 W |
DVD-ROM drive | DVD-ROM/DVD-RW drive, optional when the server is RH1288 V2 (8 hard disks). |
Rated input voltage | AC: 100 to 240 V AC DC: -48 V DC to -60 V DC NOTE: The recommended current specification for the external power circuit breaker connected to the server is 32A. AC module Emerson 800W-AC(EPW800W-AC) and DC modules not support the high tension directing current. |
Installation dimensions | The rack server can be installed in a common rack that complies with the IEC 297 standard: Width: 19 inches Depth: > 1000 mm (39.37 inches) Guide rail installation requirements are as follows: L-shaped guide rail: applies only to Huawei cabinets. Adjustable guide rail: The distance between the front rear mounting bars is 557 mm to 862 mm. |
Weight (in full configuration) | Net weight: Eight 2.5-inch HDDs: 19.6 kg (43.22 lb) Four 3.5-inch HDDs: 20 kg (44.10 lb) Packing material weight: 5.3 kg (11.68 lb) |