Huawei Huawei RH 1288A V2 server
  +7 (812) 309 34 73

по будням с 10:00 до 18:00

Huawei RH 1288A V2 server

Производитель: Huawei
Код товара: Huawei RH1288A V2 server
Артикул: ART7979

Цена договорная

Сроки: 14 дней
Нашли дешевле?

+7 (812) 309 34 73. Договоримся!

Specification
Input voltage AC: 100-240 V AC (with an input frequency of 50 Hz or 60 Hz)
240 V HV DC: 192-288 V DC
NOTE:
The recommended current specification for the external power circuit breaker connected to the RH1288A V2 is 32 A.
Chipset Intel C602
Storage ·The RH1288A V2 supports the following hard disk configurations:
·RH1288A V2-8S: eight front 2.5-inch SAS HDDs (7.2 TB), SATA HDDs (8 TB), or SSDs (4.8 TB)
·RH1288A V2-4L: four front 3.5-inch SAS HDDs (4 TB) or SATA HDDs (16 TB)
·Hard disks are hot-swappable.
·The server supports RAID 0, 1, 10, 1E, 5, 50, 6, and 60. It protects cache data from power failures, and supports RAID state migration, RAID configuration memory, self-diagnosis, and web-based configuration.
·The mainboard can be configured with a SAS adapter or SAS RAID controller card (with a maximum of 1 GB cache) to improve hard disk storage performance and ensure user data security.
·The RAID controller card does not occupy a standard PCIe slot, improving system scalability.
Processor Up to two Intel® Xeon® E5-2600 v2 series processors:
·Number of cores per processor: 10 cores (2.4 GHz), 8 cores (2.6 GHz), 6 cores (2.6 GHz), and 4 cores (2.5 GHz)
·Number of QPI links: 2
·Maximum transmission speed per QPI link: 8.0 GT/s
·Maximum memory speed: 1866 MHz
·Maximum L3 cache capacity: 25 MB
Up to two Intel® Xeon® E5-2600 series processors:
·Number of cores per processor: 8 cores (2.2 GHz), 6 cores (2.5 GHz), and 4 cores (2.4 GHz)
·Number of QPI links: 2
·Maximum transmission speed per QPI link: 8.0 GT/s
·Maximum memory speed: 1600 MHz
·Maximum L3 cache capacity: 20 MB
Humidity Operating humidity: 8% RH to 90% RH (non-condensing)
Storage humidity: 5% RH to 95% RH (non-condensing)
Humidity change rate: < 20% RH/hour
Long-term storage humidity: 30% RH to 69% RH (non-condensing)
Acoustic Noise The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7999 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle:
LWAd: 5.9Bels
LpAm: 43dBA
Operating:
LWAd: 6.7Bels
LpAm: 50.1dBA
NOTE:
The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.
Temperature Operating temperature: 5°C to 35°C (41°F to 95°F)
Storage temperature: –40°C to +65°C (–40 F to +149 F)
Temperature change rate: < 20°C/h (36°F/h)
Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)
Power rating 460 W
Altitude 3000 m (9842.40 ft) When the altitude is higher than 900 m (2952.72 ft), the operating temperature decreases by 1°C (33.8°F) per 300 m (984.24 ft).
Security Power-on password
Administrator password
Form factor 1 U rack server
Dimensions (H x W x D) 43.6 mm x 447 mm x 740 mm (1.78 in. x 17.05 in. x 29.13 in.)
Port Ports on the front panel:
Two USB 2.0 ports
One DB15 video port (provided by the RH1288A V2-8S)
Ports on the rear panel:
Two USB 2.0 ports
One DB15 video port
One DB9 serial port
One RJ45 system management port
One built-in USB port (for the embedded system management program)
DIMM ·Up to 8 DIMM slots (4 DIMMs per processor) for installing either RDIMMs or LRDIMMs
·8 x 32 GB RDIMMs for two processors, with a maximum memory capacity of 256 GB
·8 x 32 GB LRDIMMs for two processors, with a maximum memory capacity of 256 GB
·Maximum memory speed: 1866 MHz (E5-2600 v2)
·Data protection measures: ECC, memory mirroring, Single Device Data Correction (SDDC), memory sparing, and lockstep
Network port Two GE ports (Intel I350) on the mainboard, supporting NC-SI, WOL, and PXE
PCIe slot The server provides three PCIe slots: one for a full-height full-length PCIe card, one for a half-height half-length PCIe card, and one for a non-standard RAID controller card.
One Huawei PCIe intelligent network interface card (iNIC), which improves the I/O bandwidth and throughput.
One Huawei SSD card, which greatly improves I/O performance for search, cache, and download services.
NVS315 GPU.
GPU The mainboard integrates the SM750 display chip and provides 32 MB display memory. The maximum resolution is 1920 pixels x 1200 pixels at 60 Hz with 16 M colors.
Installation dimensions The RH1288A V2 fits into a common rack complying with the IEC 297 standard.
Rack width: 19 in.
Rack depth: > 1000 mm (39.37 in.)
Guide rail installation requirements are as follows:
L-shaped guide rails: apply only to Huawei racks.
Adjustable guide rail: The distance between the front rear mounting bars is 557 mm to 862 mm.
Weight in full configuration Net weight:
RH1288A V2-8S: 19.6 kg
RH1288A V2-4L: 20 kg
Packaging materials: 5.3 kg (11.69 lb)
Fan module Five hot-swappable fan modules, tolerating the failure of a single fan. Each fan module consists of two counter-rotating fans.
PSU Two hot-swappable 460 W AC PSU in redundancy mode, supporting efficiency of up to 94 percent.
System management UEFI
Huawei iBMC: supports Intelligent Platform Management Interface (IPMI), Serial over LAN (SOL), KVM over IP, and virtual media, and provides one 10/100/1000M RJ-45 management network port.
NC-SI
  Написать отзыв