Huawei’s FusionServer RH5885H V3 is a next-generation 4U, 4-socket rack server that supports Intel® Xeon® E7 v3 and v4 series processors with up to 96 cores and a 6 TB memory capacity. It is ideal for mission-critical applications, such as databases, Enterprise Resource Planning (ERP), Business Intelligence (BI) analytics, Big Data, and virtualization. Get high reliability and better performance with Huawei’s RH5885H V3 rack server.
Быстрые спецификацииs
На рисунке 1 показан внешний вид Huawei FusionServer RH5885H V3 Rack Server.
Таблица 1 показывает Быстрые спецификацииs.
Product |
Huawei FusionServer RH5885H V3 Rack Server |
Form factor |
4U rack server |
Number of processors |
24 |
Processor model |
Intel® Xeon® E7-4800 v3/v4E7-8800 v3/v4 processors, with an L3 cache capacity of 60 MB maximum |
Number of DIMM slots |
96 DIMMs, up to 6 TB (using 64 GB DIMMs) |
Memory |
96 DIMMs |
Internal Storage |
823 x 2.5-inch SAS/SATA HDDsSSDs,8 x 2.5-inch SAS/SATA HDDs + 4 x 2.5-inch NVMes |
RAID |
·RAID 0, 1, 10, 5, 50, 6,60 ·Configured with a supercapacitorBattery Backup Unit (BBU) for power-off protection (optional) |
LOM Network Ports |
2 GE4 GE ports,2 x 10 GE ports |
PCIe Expansion |
Up to 17 PCIe slots (including one for RAID) |
Fan Modules |
5 hot-swappable fan modules in N+1 redundancy mode |
Power Supply Units |
Hot-swappable PSUs in 1+12+2 redundancy mode |
Management |
·Provides independent ports; supports standard management interfaces, such as SNMP and IPMI; provides GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring ·Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft System Center, and Nagios |
Operating Temperature |
5ºC to 40ºC (41ºF to 104ºF), ASHRAE Class A3 compliant |
Dimensions (H x W x D) |
447 mm x 790 mm x 175 mm (17.60 in. x 31.10 in. x 6.89 in.) |
Детали продукта
На рисунке 2 показана передняя панель Huawei FusionServer RH5885H V3 Rack Server.
Note:
? |
Fan modules (numbered 1 to 5 from left to right) |
? |
Network port link status indicators |
? |
Health indicator |
? |
UID button/indicator |
? |
Power button/indicator |
? |
Fan status indicator |
? |
Label (including the ESN label) |
? |
Hard disk fault indicator |
? |
Hard disk activity indicator |
? |
Hard disks |
? |
DVD drive |
? |
LED diagnosis panel |
? |
VGA port |
? |
USB port 2 |
? |
USB port 1 |
- |
- |
На рисунке 3 показана задняя панель Huawei FusionServer RH5885H V3 Rack Server.
Note:
? |
PCIe card status indicator (hot-swappable PCIe card) |
? |
PCIe card power indicator (hot-swappable PCIe card) |
? |
PCIe card hot swap button (hot-swappable PCIe card) |
? |
PCIe riser card 1 (supporting non-hot-swappable PCIe cards) |
? |
LOM |
? |
UID indicator |
? |
Serial port |
? |
VGA port |
? |
iMana 200 or iBMC management network port |
? |
USB port |
? |
PCIe riser card 2 (supporting non-hot-swappable PCIe cards) |
? |
PSU (in 2-PSU mode, PSU 1 to PSU 2 from left to right; in 4-PSU mode, PSU 1 to PSU 4 from left to right) |
? |
PSU indicator |
? |
PCIe riser card 3 (supporting hot-swappable PCIe cards) |
Сравнить похожие товары
Table 3 shows the comparison of Huawei FusionServer RH5885H V3 Rack Server, Huawei FusionServer RH5885 V3 Rack Server and Huawei FusionServer 5288 V3 rack server.
Product |
Huawei FusionServer RH5885H V3 Rack Server |
Huawei FusionServer RH5885 V3 Rack Server |
Huawei FusionServer 5288 V3 rack server |
Form factor |
4U rack server |
4U rack server |
4 U rack server |
Number of processors |
24 |
24 |
Onetwo |
Processor model |
Intel® Xeon® E7-4800 v3/v4E7-8800 v3/v4 processors, with an L3 cache capacity of 60 MB maximum |
Intel® Xeon® E7-4800 v3/v4E7-8800 v3/v4 processors, with an L3 cache capacity of 60 MB maximum |
Intel® Xeon® E5-2600 v3/v4 series processors |
Number of DIMM slots |
96 DIMMs, up to 6 TB (using 64 GB DIMMs) |
48 DIMMs, up to 3 TB (64 GB DIMMs) |
816 slots for DDR4 RDIMMsLRDIMMs |
Memory |
96 DIMMs |
48 DIMMs |
16 DDR4 RDIMMs/LRDIMMs |
Internal Storage |
823 x 2.5-inch SAS/SATA HDDsSSDs,8 x 2.5-inch SAS/SATA HDDs + 4 x 2.5-inch NVMes |
823 x 2.5-inch SAS/SATA HDDsSSDs,8 x 2.5-inch SAS/SATA HDDs + 4 x 2.5-inch NVMes |
5288 V3 with 40 hard disks Rear: ·16 x 3.5-inch SAS/SATA HDDs·14 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDsSAS/SATA HDDs ·12 x 3.5-inch SAS/SATA HDDs + 4 x 2.5-inch SSDsSAS/SATA HDDs
Rear: ·4 x 3.5-inch SAS/SATA HDDs·2 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDsSAS/SATA HDDs ·4 x 2.5-inch SSDsSAS/SATA HDDs |
Что бы получить больше информации
У вас есть какие-либо вопросы о Huawei FusionServer RH5885H V3 Rack Server?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
Input voltage | Two PSUs: 2500 W DC PSUs: –48 V DC to –60 V DC 2000 W AC PSUs: 100 V AC to 240 V AC, 50 Hz/60 Hz 240 V DC 3000 W AC PSUs: 100 V AC to 240 V AC, 50 Hz/60 Hz 240 V DC Four PSUs: 800 W AC PSUs: 100 V AC to 240 V AC, 50 Hz/60 Hz 240 V DC NOTE: Recommended current for external circuit breakers: DC: 63 A AC: 32 A 380 V HVDC: 32 A |
Chipset | Intel Patsburg PCH. |
Processor | A maximum of four Intel® Xeon® E7-4800 or E7-8800 v2 (Ivy Bridge-EX) processors, with up to 15 cores and 37.5 MB L3 cache per processor. A maximum of four Intel® Xeon® E7-4800 or E7-8800 v3 (Haswell-EX) processors, with up to 18 cores and 45 MB L3 cache per processor. A maximum of four Intel® Xeon® E7-4800 or E7-8800 v4 (Broadwell-EX) processors, with up to 24 cores and 60 MB L3 cache per processor. |
Expansion slot | The RH5885H V3 supports a non-standard PCIe slot dedicated for a RAID controller card. The RH5885H V3 also supports various PCIe risers with different PCIe specifications: 16 standard PCIe slots Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover Eight PCIe 3.0 x8 slots for installing full-height full-length cards Two PCIe 3.0 x4 slots for installing full-height full-length cards Two PCIe 2.0 x4 slots for installing full-height full-length cards 12 standard PCIe slots Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover Four PCIe 3.0 x16 slots for installing full-height full-length cards Two PCIe 3.0 x4 slots for installing full-height full-length cards Two PCIe 2.0 x4 slots for installing full-height full-length cards 14 standard PCIe slots Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover Four PCIe 3.0 x8 slots for installing full-height full-length cards Two PCIe 3.0 x16 slots for installing full-height full-length cards Two PCIe 3.0 x4 slots for installing full-height full-length cards Two PCIe 2.0 x4 slots for installing full-height full-length cards NOTICE: The RH5885H V3 cannot be equipped with Huawei ES3000 V3 NVMe PCIe SSD cards and Intel NVMe PCIe SSDs at the same time. When Huawei ES3000 V3 NVMe PCIe SSD cards are installed, upgrade the ES3000 V3 driver to the latest version. |
Temperature | Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant) Storage temperature: -40°C to +65°C (-40°F to +149°F) Maximum temperature change rate: 20°C/h (36°F/h) Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F) NOTE: If an SSD card or a GPU is configured, the maximum operating temperature is 35°C (95°F). |
Acoustic noise | The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Idle: LWAd: 7.1 Bels LpAm: 58.8 dBA Operating: LWAd: 7.1 Bels LpAm: 58.8 dBA NOTE: The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature. |
Altitude | 3000 m (9842.40 ft) The highest operating temperature decreases by 1°C (1.8°F) with every increase of 300 m (984.24 ft) in an altitude above 900 m (2952.72 ft). At an altitude of over 3000 m (9842.5 ft), only Titanium PSUs can be used. HDDs are not supported at an altitude of over 3000 m (9842.5 ft). |
Input current | DC PSUs: 63 A AC PSUs: 10 A or 16 A HVDC PSUs: 10 A or 16 A NOTE: 2000 W PSUs: 25 A fuse 2500 W PSUs: 50 A fuse 3000 W PSUs: 25 A fuse 800 W PSUs: 12.5 A fuse |
Form factor/height | 4U rack server, supporting hold rails and cable management assemblies. |
DIMM slot | 96 slots for installing DDR3 or DDR4 DIMMs. There are 8 memory risers in total. Each processor supports two memory risers, and each memory riser supports 8 or 12 DIMMs. |
Hard disk tray | 8 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs. 23 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs. 8 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs + 4 x 2.5-inch scheduled hot-swappable NVMe PCIe SSDs. NOTICE: The RH5885H V3 cannot be equipped with Huawei ES3000 V3 NVMe PCIe SSDs and Intel NVMe PCIe SSDs at the same time. When Huawei ES3000 V3 NVMe PCIe SSDs are installed, upgrade the ES3000 V3 driver to the latest version. |
Maximum memory capacity | 6 TB (using 64 GB DIMMs). |
Maximum local storage capacity | 8 hard disks: 8 x 1.2 TB = 9.6 TB 23 hard disks: 23 x 1.2 TB = 27.6 TB 8 + 4 hard disks: 8 x 1.2 TB + 4 x 2 TB = 17.6 TB NOTE: The RH5885H V3 supports 8, 23, and 8 + 4 hard disk configurations. |
Network port | The onboard NIC can be flexibly configured to provide either of the following ports: Four integrated GE 1000BASE-T ports Two 10GE optical ports Two GE electrical ports |
Rated power | Two or four PSUs can be installed on one server. PSU rated power: Two PSUs: 2500 W DC PSUs: 2500 W (input voltage: –48 V DC to –60 V DC) 2000 W AC PSUs: 800 W (input voltage: 100 V to 130 V AC) 1800 W (input voltage: 200 V to 220 V AC) 2000 W (input voltage: 220 V to 240 V AC) 2000 W (input voltage: 240 V DC) 3000 W AC PSUs: 1200 W (input voltage: 100 V to 130 V AC) 2500 W (input voltage: 200 V to 220 V AC) 3000 W (input voltage: 220 V to 240 V AC) 3000 W (input voltage: 240 V DC) Four PSUs: 800 W AC PSUs: 600 W (input voltage: 100 V to 127 V AC) 800 W (input voltage: 200 V to 240 V AC) 800 W (input voltage: 240 V DC) |
External port | Front panel: two USB 2.0 ports, one power button, one UID button, one video graphics array (VGA) port, and one touched diagnostic LCD. Rear panel: two USB 2.0 ports, one VGA port, one serial port, one 100 Mbit/s management port, one UID indicator, and one plug-in NIC. |
DVD-ROM drive | One |
RAID | A RAID controller card supports either of the following: RAID 0, 1, 10, and 1E RAID 0, 1, 10, 5, 50, 6, and 60, a maximum cache capacity of 2 GB, and a supercapacitor for power-off protection |
Video card | The system mainboard integrates the display chip and provides 16 MB display memory. The maximum resolution is 1024 x 768. |
Chassis dimensions (H x W x D) | 175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10 in.) |
Installation space | The server fits into a standard cabinet that complies with the IEC 297 standard: Width: 19 in. Minimum depth: 1000 mm (39.37 in.) The guide rails to be used vary with cabinets: Use L-shaped guide rails for a Huawei cabinet. Use adjustable guide rails if the distance between the front and rear mounting bars of a cabinet is 560 mm (22.05 in.) to 858 mm (33.78 in.). Use holding rails if the distance between the front and rear mounting bars of a cabinet is 610 mm (24.02 in.) to 914 mm (35.98 in.). |
Maximum weight | 8-bay server: 52 kg (114.66 lb) 12-bay server: 53 kg (116.84 lb) 23-bay server: 56 kg (123.48 lb) NOTE: Maximum weight Includes the weight of CPUs, DIMMs, and hard disks in full configuration. Does not include the weight of the package or PCIe cards. PCIe card weight Standard half-height half-length PCIe card: 0.3 kg (0.66 lb) Standard full-height half-length PCIe card: 0.4 kg (0.88 lb) Standard full-height full-length dual-slot PCIe card (for example, a GPU): 1 kg (2.21 lb) |
Relative humidity (non-condensing) | Operating humidity: 10% to 90% Storage humidity: 5% to 95% Maximum humidity change rate: 20%/h Long-term storage humidity: 30% RH to 69% RH (non-condensing) |
Corrosive air pollutant | Corrosion rate of the copper test piece: < 300 A/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1) Corrosion rate of the silver test piece: < 200 A/month |
Particulate pollutant | The ISO14664-1 Class 8 requirements are met. You are advised to ask a professional organization to monitor particulate pollutants in the equipment room. There is no explosive, conductive, magnetic, or corrosive dust in the equipment room. |
PSU | The PSUs can be configured as follows: Two 3000 W AC PSUs in 1+1 redundancy mode Two 2000 W AC PSUs in 1+1 redundancy mode Two 2500 W DC PSUs in 1+1 redundancy mode Four 800 W AC PSUs in 2+2 redundancy mode |
Security feature | Power-on password and administrator password. Front bezel. |
System management | IPMI/SNMP/CLI |