+7 (812) 309 34 73

по будням с 10:00 до 18:00

Huawei FusionServer RH5885H V3 Rack Server

Производитель: Huawei
Код товара: Huawei FusionServer RH5885H V3 Rack Server
Артикул: ART7985
По запросу
Сроки: 14 дней
Нашли дешевле?

+7 (812) 309 34 73. Договоримся!

Specification
Input voltage Two PSUs:
2500 W DC PSUs: –48 V DC to –60 V DC
2000 W AC PSUs:
100 V AC to 240 V AC, 50 Hz/60 Hz
240 V DC
3000 W AC PSUs:
100 V AC to 240 V AC, 50 Hz/60 Hz
240 V DC
Four PSUs:
800 W AC PSUs:
100 V AC to 240 V AC, 50 Hz/60 Hz
240 V DC
NOTE:
Recommended current for external circuit breakers:
DC: 63 A
AC: 32 A
380 V HVDC: 32 A
Chipset Intel Patsburg PCH.
Processor A maximum of four Intel® Xeon® E7-4800 or E7-8800 v2 (Ivy Bridge-EX) processors, with up to 15 cores and 37.5 MB L3 cache per processor.
A maximum of four Intel® Xeon® E7-4800 or E7-8800 v3 (Haswell-EX) processors, with up to 18 cores and 45 MB L3 cache per processor.
A maximum of four Intel® Xeon® E7-4800 or E7-8800 v4 (Broadwell-EX) processors, with up to 24 cores and 60 MB L3 cache per processor.
Expansion slot The RH5885H V3 supports a non-standard PCIe slot dedicated for a RAID controller card.
The RH5885H V3 also supports various PCIe risers with different PCIe specifications:
16 standard PCIe slots
Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover
Eight PCIe 3.0 x8 slots for installing full-height full-length cards
Two PCIe 3.0 x4 slots for installing full-height full-length cards
Two PCIe 2.0 x4 slots for installing full-height full-length cards
12 standard PCIe slots
Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover
Four PCIe 3.0 x16 slots for installing full-height full-length cards
Two PCIe 3.0 x4 slots for installing full-height full-length cards
Two PCIe 2.0 x4 slots for installing full-height full-length cards
14 standard PCIe slots
Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover
Four PCIe 3.0 x8 slots for installing full-height full-length cards
Two PCIe 3.0 x16 slots for installing full-height full-length cards
Two PCIe 3.0 x4 slots for installing full-height full-length cards
Two PCIe 2.0 x4 slots for installing full-height full-length cards
NOTICE:
The RH5885H V3 cannot be equipped with Huawei ES3000 V3 NVMe PCIe SSD cards and Intel NVMe PCIe SSDs at the same time.
When Huawei ES3000 V3 NVMe PCIe SSD cards are installed, upgrade the ES3000 V3 driver to the latest version.
Temperature Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant)
Storage temperature: -40°C to +65°C (-40°F to +149°F)
Maximum temperature change rate: 20°C/h (36°F/h)
Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)
NOTE:
If an SSD card or a GPU is configured, the maximum operating temperature is 35°C (95°F).
Acoustic noise The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Idle:
LWAd: 7.1 Bels
LpAm: 58.8 dBA
Operating:
LWAd: 7.1 Bels
LpAm: 58.8 dBA
NOTE:
The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.
Altitude 3000 m (9842.40 ft)
The highest operating temperature decreases by 1°C (1.8°F) with every increase of 300 m (984.24 ft) in an altitude above 900 m (2952.72 ft).
At an altitude of over 3000 m (9842.5 ft), only Titanium PSUs can be used.
HDDs are not supported at an altitude of over 3000 m (9842.5 ft).
Input current DC PSUs: 63 A
AC PSUs: 10 A or 16 A
HVDC PSUs: 10 A or 16 A
NOTE:
2000 W PSUs: 25 A fuse
2500 W PSUs: 50 A fuse
3000 W PSUs: 25 A fuse
800 W PSUs: 12.5 A fuse
Form factor/height 4U rack server, supporting hold rails and cable management assemblies.
DIMM slot 96 slots for installing DDR3 or DDR4 DIMMs.
There are 8 memory risers in total. Each processor supports two memory risers, and each memory riser supports 8 or 12 DIMMs.
Hard disk tray 8 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs.
23 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs.
8 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs + 4 x 2.5-inch scheduled hot-swappable NVMe PCIe SSDs.
NOTICE:
The RH5885H V3 cannot be equipped with Huawei ES3000 V3 NVMe PCIe SSDs and Intel NVMe PCIe SSDs at the same time.
When Huawei ES3000 V3 NVMe PCIe SSDs are installed, upgrade the ES3000 V3 driver to the latest version.
Maximum memory capacity 6 TB (using 64 GB DIMMs).
Maximum local storage capacity 8 hard disks: 8 x 1.2 TB = 9.6 TB
23 hard disks: 23 x 1.2 TB = 27.6 TB
8 + 4 hard disks: 8 x 1.2 TB + 4 x 2 TB = 17.6 TB
NOTE:
The RH5885H V3 supports 8, 23, and 8 + 4 hard disk configurations.
Network port The onboard NIC can be flexibly configured to provide either of the following ports:
Four integrated GE 1000BASE-T ports
Two 10GE optical ports
Two GE electrical ports
Rated power Two or four PSUs can be installed on one server.
PSU rated power:
Two PSUs:
2500 W DC PSUs: 2500 W (input voltage: –48 V DC to –60 V DC)
2000 W AC PSUs:
800 W (input voltage: 100 V to 130 V AC)
1800 W (input voltage: 200 V to 220 V AC)
2000 W (input voltage: 220 V to 240 V AC)
2000 W (input voltage: 240 V DC)
3000 W AC PSUs:
1200 W (input voltage: 100 V to 130 V AC)
2500 W (input voltage: 200 V to 220 V AC)
3000 W (input voltage: 220 V to 240 V AC)
3000 W (input voltage: 240 V DC)
Four PSUs:
800 W AC PSUs:
600 W (input voltage: 100 V to 127 V AC)
800 W (input voltage: 200 V to 240 V AC)
800 W (input voltage: 240 V DC)
External port Front panel: two USB 2.0 ports, one power button, one UID button, one video graphics array (VGA) port, and one touched diagnostic LCD.
Rear panel: two USB 2.0 ports, one VGA port, one serial port, one 100 Mbit/s management port, one UID indicator, and one plug-in NIC.
DVD-ROM drive One
RAID A RAID controller card supports either of the following:
RAID 0, 1, 10, and 1E
RAID 0, 1, 10, 5, 50, 6, and 60, a maximum cache capacity of 2 GB, and a supercapacitor for power-off protection
Video card The system mainboard integrates the display chip and provides 16 MB display memory. The maximum resolution is 1024 x 768.
Chassis dimensions (H x W x D) 175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10 in.)
Installation space The server fits into a standard cabinet that complies with the IEC 297 standard:
Width: 19 in.
Minimum depth: 1000 mm (39.37 in.)
The guide rails to be used vary with cabinets:
Use L-shaped guide rails for a Huawei cabinet.
Use adjustable guide rails if the distance between the front and rear mounting bars of a cabinet is 560 mm (22.05 in.) to 858 mm (33.78 in.).
Use holding rails if the distance between the front and rear mounting bars of a cabinet is 610 mm (24.02 in.) to 914 mm (35.98 in.).
Maximum weight 8-bay server: 52 kg (114.66 lb)
12-bay server: 53 kg (116.84 lb)
23-bay server: 56 kg (123.48 lb)
NOTE:
Maximum weight
Includes the weight of CPUs, DIMMs, and hard disks in full configuration.
Does not include the weight of the package or PCIe cards.
PCIe card weight
Standard half-height half-length PCIe card: 0.3 kg (0.66 lb)
Standard full-height half-length PCIe card: 0.4 kg (0.88 lb)
Standard full-height full-length dual-slot PCIe card (for example, a GPU): 1 kg (2.21 lb)
Relative humidity (non-condensing) Operating humidity: 10% to 90%
Storage humidity: 5% to 95%
Maximum humidity change rate: 20%/h
Long-term storage humidity: 30% RH to 69% RH (non-condensing)
Corrosive air pollutant Corrosion rate of the copper test piece: < 300 A/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)
Corrosion rate of the silver test piece: < 200 A/month
Particulate pollutant The ISO14664-1 Class 8 requirements are met.
You are advised to ask a professional organization to monitor particulate pollutants in the equipment room.
There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.
PSU The PSUs can be configured as follows:
Two 3000 W AC PSUs in 1+1 redundancy mode
Two 2000 W AC PSUs in 1+1 redundancy mode
Two 2500 W DC PSUs in 1+1 redundancy mode
Four 800 W AC PSUs in 2+2 redundancy mode
Security feature Power-on password and administrator password.
Front bezel.
System management IPMI/SNMP/CLI
  Написать отзыв