+7 (812) 309 34 73. Договоримся!
Общая информация (Huawei FusionServer 5288 V3 rack server)
Huawei new-generation FusionServer 5288 V3 rack server delivers ultra-large local storage capacity, flexible resource expansion and high computing performance in 4U spaces. This rack server is ideal choice for cold date and cloud storage, video surveillance and big data applications. Huawei FusionServer 5288 V3 supports up to 2 Intel Xeon E5-2600 v3 Series processors, 16 DDR4 DIMMS, 6 PCIe 3.0 slots and 40 SASSATA disks. Moreover, Huawei FusionServer 5288 V3 uses dynamic energy management technology to adjust server operating status dynamically and limit power consumption to an optimal level, and uses proportion integration differentiation to control heat dissipation and fan speed adjustment policies, implements stepless speed regulation and on-demand allocation of heat dissipation resources, and minimizes power consumption and noise.
Быстрые спецификацииs
На рисунке 1 показан внешний вид Huawei FusionServer 5288 V3 rack server.
Таблица 1 показывает Быстрые спецификацииs.
Product |
Huawei FusionServer 5288 V3 rack server |
Form factor |
4 U rack server |
Number of processors |
Onetwo |
Processor model |
Intel® Xeon® E5-2600 v3/v4 series processors |
Number of DIMM slots |
816 slots for DDR4 RDIMMsLRDIMMs |
Memory |
16 DDR4 RDIMMs/LRDIMMs |
Internal Storage |
5288 V3 with 40 hard disks Rear: ·16 x 3.5-inch SAS/SATA HDDs·14 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDsSAS/SATA HDDs ·12 x 3.5-inch SAS/SATA HDDs + 4 x 2.5-inch SSDsSAS/SATA HDDs
Rear: ·4 x 3.5-inch SAS/SATA HDDs·2 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDsSAS/SATA HDDs ·4 x 2.5-inch SSDsSAS/SATA HDDs |
RAID |
·RAID 0, 1, 10, 5, 50, 6,60 ·Configured with a supercapacitor for power-off protection for the cache (optional) ·RAID state transition, configuration memory, self-diagnosis, and web-based remote configuration |
LOM Network Ports |
Supported network configurations: ·2 GE electrical ports, supporting Network Controller Sideband Interface (NC-SI), Wake on LAN (WoL), and pre-boot execution environment (PXE)·4 GE electrical ports, supporting NC-SI, WoL, and PXE ·2 x 10 GE optical ports, supporting NC-SI and PXE ·2 x 10 GE electrical ports, supporting NC-SI, WoL, and PXE ·2 GE electrical ports and 2 x 10 GE optical ports, supporting NC-SI, WoL, and PXE |
PCIe Expansion |
Up to 6 PCIe 3.0 slots |
Fan Modules |
Hot-swappable fan modules in N+1 redundancy mode |
Power Supply Units |
2 hot-swappable PSUs in 1+1 redundancy mode |
Management |
·Uses Huawei Hi1710 management chip and independent ports ·Supports standard management interfaces, such as SNMP and IPMI; provides GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring ·Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft System Center, and Nagios |
Operating Temperature |
5ºC to 40ºC (41ºF to 104ºF), ASHRAE Class A3 compliant |
Dimensions (H x W x D) |
175 mm x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.) |
Детали продукта
На рисунке 2 показана передняя панель Huawei FusionServer 5288 V3 rack server.
Note:
? |
Network port link status indicators |
? |
USB 2.0 port |
? |
Hard disk fault indicator |
? |
Hard disk activity indicator |
? |
Hard disks (numbered 0 to 23 from top to bottom and from left to right) |
? |
Fault diagnosis LED |
? |
Health indicator |
? |
UID button/indicator |
? |
Power button/indicator |
На рисунке 3 показана задняя панель Huawei FusionServer 5288 V3 rack server.
Note:
? |
Rear hard disk |
? |
Hard disk fault indicator |
? |
Hard disk activity indicator |
? |
I/O module |
? |
PSU port |
? |
PSU indicator |
? |
PSU |
? |
Serial port |
? |
VGA port |
? |
Connectivity status indicator |
? |
Management network port (Mgmt) |
? |
Data transmission status indicator |
? |
USB 3.0 port |
? |
UID indicator |
? |
PCIe slot |
? |
LAN on motherboard (LOM) |
? |
Rear hard disk |
– |
– |
Сравнить похожие товары
Table 3 shows the comparison of Huawei FusionServer 5288 V3 rack server, Huawei FusionServer RH5885 V3 Rack Server and Huawei FusionServer RH5885H V3 Rack Server.
Product |
Huawei FusionServer 5288 V3 rack server |
Huawei FusionServer RH5885 V3 Rack Server |
Huawei FusionServer RH5885H V3 Rack Server |
Form factor |
4 U rack server |
4U rack server |
4U rack server |
Number of processors |
Onetwo |
24 |
24 |
Processor model |
Intel® Xeon® E5-2600 v3/v4 series processors |
Intel® Xeon® E7-4800 v3/v4E7-8800 v3/v4 processors, with an L3 cache capacity of 60 MB maximum |
Intel® Xeon® E7-4800 v3/v4E7-8800 v3/v4 processors, with an L3 cache capacity of 60 MB maximum |
Number of DIMM slots |
816 slots for DDR4 RDIMMsLRDIMMs |
48 DIMMs, up to 3 TB (64 GB DIMMs) |
96 DIMMs, up to 6 TB (using 64 GB DIMMs) |
Memory |
16 DDR4 RDIMMs/LRDIMMs |
48 DIMMs |
96 DIMMs |
Internal Storage |
5288 V3 with 40 hard disks Rear: ·16 x 3.5-inch SAS/SATA HDDs·14 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDsSAS/SATA HDDs ·12 x 3.5-inch SAS/SATA HDDs + 4 x 2.5-inch SSDsSAS/SATA HDDs
Rear: ·4 x 3.5-inch SAS/SATA HDDs·2 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDsSAS/SATA HDDs ·4 x 2.5-inch SSDsSAS/SATA HDDs |
823 x 2.5-inch SAS/SATA HDDsSSDs,8 x 2.5-inch SAS/SATA HDDs + 4 x 2.5-inch NVMes |
823 x 2.5-inch SAS/SATA HDDsSSDs,8 x 2.5-inch SAS/SATA HDDs + 4 x 2.5-inch NVMes |
Что бы получить больше информации
У вас есть какие-либо вопросы о Huawei FusionServer 5288 V3 rack server?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
Number of processors | One or two |
Memory | 16 DDR4 RDIMMs/LRDIMMs |
Form factor | 4 U rack server |
Dimensions (H x W x D) | 175 mm x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.) |
Management | ·Uses Huawei Hi1710 management chip and independent ports ·Supports standard management interfaces, such as SNMP and IPMI; provides GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring ·Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft System Center, and Nagios |
Operating Temperature | 5 C to 40 C (41 F to 104 F), ASHRAE Class A3 compliant |
Certification | CE, UL, FCC, CCC, and RoHS |
Processor model | Intel® Xeon® E5-2600 v3/v4 series processors |
Number of DIMM slots | 8 or 16 slots for DDR4 RDIMMs or LRDIMMs |
LOM Network Ports | Supported network configurations: ·2 GE electrical ports, supporting Network Controller Sideband Interface (NC-SI), Wake on LAN (WoL), and pre-boot execution environment (PXE) ·4 GE electrical ports, supporting NC-SI, WoL, and PXE ·2 x 10 GE optical ports, supporting NC-SI and PXE ·2 x 10 GE electrical ports, supporting NC-SI, WoL, and PXE ·2 GE electrical ports and 2 x 10 GE optical ports, supporting NC-SI, WoL, and PXE |
Fan Modules | Hot-swappable fan modules in N+1 redundancy mode |
Power Supply Units | 2 hot-swappable PSUs in 1+1 redundancy mode |
PCIe expansion | A maximum of six PCIe slots. |
RAID | ·RAID 0, 1, 10, 5, 50, 6, or 60 ·Configured with a supercapacitor for power-off protection for the cache (optional) ·RAID state transition, configuration memory, self-diagnosis, and web-based remote configuration |
Supported OS | ·CentOS · Citrix XenServer · Microsoft Windows Sever · Red Hat Enterprise Linux · SUSE Linux Enterprise Server · VMware ESXi |
Installation suite | ·Guide rails ·Hold rails and cable management arm (optional) |
PSU | ·Two hot-swappable PSUs in 1+1 redundancy ·Supports 750 W and 1200 W Platinum AC PSUs. |
PCIe Expansion | Up to 6 PCIe 3.0 slots |
Internal Storage | 5288 V3 with 40 hard disks Front: ·24 x 3.5-inch SAS/SATA HDDs Rear: ·16 x 3.5-inch SAS/SATA HDDs ·14 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDs or SAS/SATA HDDs ·12 x 3.5-inch SAS/SATA HDDs + 4 x 2.5-inch SSDs or SAS/SATA HDDs 5288 V3 with 28 hard disks Front: ·24 x 3.5-inch SAS/SATA HDDs Rear: ·4 x 3.5-inch SAS/SATA HDDs ·2 x 3.5-inch SAS/SATA HDDs + 2 x 2.5-inch SSDs or SAS/SATA HDDs ·4 x 2.5-inch SSDs or SAS/SATA HDDs |