Specification
Dimensions (D X W X H) 46.74 x 44.27 x 4.32 cm (18.4 x 17.43 x 1.7 in) (1U height)
Device management RFC 1591 DNS (client)
RFC 2576 (Coexistence between SNMP V1, V2, V3)
RFC 2579 (SMIv2 Text Conventions)
RFC 2580 (SMIv2 Conformance)
RFC 3416 (SNMP Protocol Operations v2)
RFC 3417 (SNMP Transport Mappings)
HTML and telnet management
General protocols IEEE 802.1ad Q-in-Q
IEEE 802.1AX-2008 Link Aggregation
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1v VLAN classification by Protocol and Port
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3af Power over Ethernet
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 868 Time Protocol
RFC 951 BOOTP
RFC 1058 RIPv1
RFC 1350 TFTP Protocol (revision 2)
RFC 1519 CIDR
RFC 1542 BOOTP Extensions
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2453 RIPv2
RFC 2548 (MS-RAS-Vendor only)
RFC 3046 DHCP Relay Agent Information Option
RFC 3575 IANA Considerations for RADIUS
RFC 3576 Ext to RADIUS (CoA only)
RFC 3768 VRRP
RFC 4675 RADIUS VLAN & Priority
RFC 3768 VRRP
RFC 4675 RADIUS VLAN & Priority
RFC 5798 VRRP (exclude Accept Mode and sub-sec timer)
RFC 5905 Network Time Protocol Version 4: Protocol and Algorithms Specification
UDLD (Uni-directional Link Detection)
Power supplies (2 power supply slots 1 minimum power supply requ 1 x J9581A (HP X311 400 W 100-240 V ac to 12 V dc power supply)
IP multicast RFC 3376 IGMPv3 (host joins only)
RFC 3973 Draft 2 PIM Dense Mode
RFC 4601 Draft 10 PIM Sparse Mode
Maximum heat dissipation 635 BTU/hr (669.93 kJ/hr)
Voltage 100-127/200-240 V ac
Current 6/3 A
Idle power 74 W
QoS/CoS RFC 2474 DiffServ Precedence, including 8 queues/port
RFC 2475 DiffServ Architecture
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 2598 DiffServ Expedited Forwarding (EF)
Maximum power rating 186 W
PoE power -
Nonoperating/Storage temperature -40° to 70°C (-40° to 158°F)
Conducted IEC 61000-4-6; 3 V
Nonoperating/Storage relative humidity 15% to 90% @ 65°C (149°F), noncondensing
Power frequency magnetic field IEC 61000-4-8; 1 A/m, 50 or 60 Hz
Voltage dips and interruptions IEC 61000-4-11; >95% reductions, 0.5 period; 30% reduction, 25 periods
Acoustic Power: 34 dB, Pressure: 24.5 dB
Harmonics EN 61000-3-2, IEC 61000-3-2
Flicker EN 61000-3-3, IEC 61000-3-3
10 Gb/s latency <1.9 s (LIFO 64-byte packets)
Memory and processor HPE ProVision ASIC/ARM @ 350 MhzHP ProVision ASIC/ARM @ 350 Mhz
Freescale PowerPC @ 1200 MHz, 4 GB flash, 2 GB SDRAM
Packet buffer size: 36MB dynamic
Throughput (64-byte packets) 130.9 million packets per sec
Routing table size 10000 entries
1000Mb latency <2.8 s (LIFO 64-byte packets)
EN EN 55024, CISPR 24
ESD IEC 61000-4-2
Switching capacity 176 Gb/s
Radiated IEC 61000-4-3; 3 V/m
MAC address table size 65500 entries
EFT/Burst IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
Surge IEC 61000-4-5; 1 or 2 kV ac
OSPF RFC 2328 OSPFv2
RFC 3101 OSPF NSSA
RFC 3623 Graceful OSPF Restart (Unplanned Outages only)
RFC 5340 OSPFv3 for IPv6
Emissions FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
Network management IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events)
RFC 3176 sFlow
RFC 3411 SNMP Management Frameworks
RFC 3412 Message Processing and Dispatching for the Simple Network Management Protocol (SNMP)
RFC 3413 Simple Network Management Protocol (SNMP) Applications
RFC 3414 User-based Security Model (USM) for version 3 of the Simple Network Management Protocol (SNMPv3)
RFC 3415 View-based Access Control Model (VACM) for the Simple Network Management Protocol (SNMP)
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
RFC 3418 Management Information Base (MIB) for the Simple Network Management Protocol (SNMP)
RFC 5424 Syslog Protocol
ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
SNMPv1/v2c/v3
XRMON
Fan tray 1 x J9582A
1 fan tray slot
MIBs IEEE 802.1ap (MSTP and STP MIB's only)
IEEE 8021-Bridge-MIB (2008)
IEEE 8021-Q-Bridge-MIB (2008)
RFC 1155 Structure & ID of Mgmt Info for TCP/IP Internets
RFC 1213 MIB II
RFC 1493 Bridge MIB
RFC 1724 RIPv2 MIB
RFC 1850 OSPFv2 MIB
RFC 2021 RMONv2 MIB
RFC 2096 IP Forwarding Table MIB
RFC 2613 SMON MIB
RFC 2618 RADIUS Client MIB
RFC 2620 RADIUS Accounting MIB
RFC 2665 Ethernet-Like-MIB
RFC 2668 802.3 MAU MIB
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB
RFC 2737 Entity MIB (Version 2)
RFC 2787 VRRP MIB
RFC 2863 The Interfaces Group MIB
RFC 2925 Ping MIB
RFC 2932 IP (Multicast Routing MIB)
RFC 2933 IGMP MIB
RFC 4836 Managed Objects for 802.3 Medium Attachment Units (MAU)
Operating temperature 0° to 55°C (32° to 131°F); Max temperature is 45°C when SFP+ Tranceivers are installed.
Altitude Up to 3 km (10,000 ft)
Security IEEE 802.1X Port Based Network Access Control
RFC 1321 The MD5 Message-Digest Algorithm
RFC 1492 TACACS+
RFC 2818 HTTP Over TLS
RFC 2865 RADIUS (client only)
RFC 2866 RADIUS Accounting
RFC 3579 RADIUS Support For Extensible Authentication Protocol (EAP)
Access Control Lists (ACLs)
MAC Authentication
MAC Lockdown
MAC Lockout
Port Security
Secure Sockets Layer (SSL)
SSHv1/SSHv2 Secure Shell
SSHv2 Secure Shell
Web Authentication
IPv6 RFC 1981 IPv6 Path MTU Discovery
RFC 2080 RIPng for IPv6
RFC 2081 RIPng Protocol Applicability Statement
RFC 2082 RIP-2 MD5
RFC 2375 IPv6 Multicast Address Assignments
RFC 2460 IPv6 Specification
RFC 2464 Transmission of IPv6 over Ethernet Networks
RFC 2710 Multicast Listener Discovery (MLD) for IPv6
RFC 2925 Remote Operations MIB (Ping only)
RFC 3019 MLDv1 MIB
RFC 3315 DHCPv6 (client only)
RFC 3484 Default Address Selection for IPv6
RFC 3587 IPv6 Global Unicast Address Format
RFC 3596 DNS Extension for IPv6
RFC 3810 MLDv2 (host joins only)
RFC 4022 MIB for TCP
RFC 4087 IP Tunnel MIB
RFC 4113 MIB for UDP
RFC 4213 Basic Transition Mechanisms for IPv6 Hosts and Routers
RFC 4251 SSHv6 Architecture
RFC 4252 SSHv6 Authentication
RFC 4253 SSHv6 Transport Layer
RFC 4254 SSHv6 Connection
RFC 4291 IP Version 6 Addressing Architecture
RFC 4293 MIB for IP
RFC 4294 IPv6 Node Requirements
RFC 4419 Key Exchange for SSH
RFC 4443 ICMPv6
RFC 4541 IGMP & MLD Snooping Switch
RFC 4861 IPv6 Neighbor Discovery
RFC 4862 IPv6 Stateless Address Auto-configuration
RFC 5095 Deprecation of Type 0 Routing Headers in IPv6
RFC 5340 OSPFv3 for IPv6
RFC 5453 Reserved IPv6 Interface Identifiers
RFC 5519 Multicast Group Membership Discovery MIB (MLDv2 only)
RFC 5722 Handling of Overlapping IPv6 Fragments
RFC 6620 FCFS SAVI
draft-ietf-savi-mix
Frequency 50/60 Hz
Safety EN 60950/IEC 60950; UL 60950; CAN/CSA 22.2 No. 60950; EN 60825
Type HP E3800-48G-4XG Switch
Operating relative humidity 15% to 95% @ 40°C (104°F), noncondensing
Ports 48 RJ-45 autosensing 10/100/1000 ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASE-TX, IEEE 802.3ab Type 1000BASE-T)
Duplex: 10BASE-T/100BASE-TX: half or full
1000BASE-T: full only
4 RJ-45 10-GbE ports IEEE 802.3an-2006 Type 10GBASE-T
Duplex: full only
1 RJ-45 serial console port
1 RJ-45 out-of-band management port
1 Stacking module slot
Weight 7.42 kg (16.36 lb)