+7 (812) 309 34 73

по будням с 10:00 до 18:00

C9500-24Y4C-1E

Производитель: Cisco
Код товара: C9500-24Y4C-1E - Cisco Switch Catalyst 9500
Артикул:
По запросу
Сроки: 14 дней
Нашли дешевле?

+7 (812) 309 34 73. Договоримся!

Характеристики
Altitude Operation up to 13,000 feet at 40°C
ASIC UADP 3.0
Dimensions (H x W x D) 1.73 x 17.5 x 18.0 in
DRAM 16 GB
EMI and EMC Compliance •47 CFR Part 15 Class A•CNS13438: 2006 Class A•EN 300 386 V1.6.1•EN61000-3-2: 2014•EN61000-3-3: 2013•ICES-003 Issue 6: 2016 Class A•KN 32: 2015 Class A•TCVN 7189: 2009 Class A•EN 55032:2012/ AC:2013 Class A•EN 55032:2015 Class A•CISPR 32 Edition 2 Class A•V-2/2015.04 Class A•V-3/2015.04 Class A•CISPR24: 2010 + A1: 2015•EN 300 386 V1.6.1•EN55024: 2010 + A1: 2015•KN35: 2015•TCVN 7317: 2003
Flash 16 GB
FNF entries Up to 98,000
Forwarding Rate Up to 1 Bpps
Input voltage 90 to 264 VAC
Jumbo frame 9216 bytes
Minimum software requirement Cisco IOS XE Software Release 16.8.1a
MTBF (Hours) 336,780
NEBS criteria levels NEBS:•Normal operating temperature range: 5C to 40C (up to 1829 meters (6000 ft)•Short term operating temperature range: -5C to 55C•Normal Relative Humidity range: 5% to 85%•Short term Relative Humidity range: 5% to 93%•Operating Altitude: up to 1829 m (6000 ft) at 55C•ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations.•SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue
Operating Temperature 32°to 104°F (0°to 40°C)
Product Code C9500-24Y4C-1E
Product Description 9500 1Y DNA Essentials, HW
QoS ACL scale Up to 16000
Rack Units (RU) 1 RU
Relative humidity operating and nonoperating noncondensing Ambient (noncondensing) operating: 5% to 90%Ambient (noncondensing) nonoperating and storage: 5% to 95%
Safety Certifications C9500-12Q, C9500-24Q, C9500-40X, C9500-16X•UL 60950-1•CAN/CSA-C22.2 No. 60950-1•EN 60950-1•IEC 60950-1•AS/NZS 60950-1•GB4943C9500-32C, C9500-32QC, C9500-24Y4C, C9500-48Y4C•IEC 60950-1 plus Am1, Am2 Am9, Am10, Am11, Am12 and all deviations and differences•AS/NZS 60950.1.2011•CAN/CSA-C22.2 No. 60950-1-07•GB 4943-95•EN 60950-1; 2006 plus Am1, Am 2, Am9, Am10, Am11, Am12 and all deviations and differences•NOM-019-SCFI-1998•UL 60950-1, Second Edition
Security ACL scale Up to 27000
Storage temperature -4°to 149°F (-20°to 65°C)
Switching capacity Up to 2.0Tbps
Total number of IPv4 Multicast routes Up to 32,000
Total number of IPv4 routes (Address Resolution Protocol [ARP] p Up to 212,000 indirect + directUp to 90,000 host/ARP
Total number of IPv6 Multicast routes Up to 32,000
Total number of IPv6 routes Up to 212,000 indirect + directUp to 90,000 host
Total number of MAC addresses Up to 82,000
Total Switched Virtual Interfaces (SVIs) 4000
VLAN IDs 4094