+7 (812) 309 34 73

по будням с 10:00 до 18:00

C9500-16X-EDU

Производитель: Cisco
Код товара: C9500-16X-EDU - Cisco Switch Catalyst 9500
Артикул:
По запросу
Сроки: 14 дней
Нашли дешевле?

+7 (812) 309 34 73. Договоримся!

Характеристики
Altitude Operation up to 13,000 feet at 40°C
ASIC UADP 2.0
Dimensions (H x W x D) 1.73 x 17.5 x 21.52 in
DRAM 16 GB
EMI and EMC Compliance •47 CFR Part 15 Class A•CNS13438: 2006 Class A•EN 300 386 V1.6.1•EN61000-3-2: 2014•EN61000-3-3: 2013•ICES-003 Issue 6: 2016 Class A•KN 32: 2015 Class A•TCVN 7189: 2009 Class A•EN 55032:2012/ AC:2013 Class A•EN 55032:2015 Class A•CISPR 32 Edition 2 Class A•V-2/2015.04 Class A•V-3/2015.04 Class A•CISPR24: 2010 + A1: 2015•EN 300 386 V1.6.1•EN55024: 2010 + A1: 2015•KN35: 2015•TCVN 7317: 2003
Flash 16 GB
FNF entries Up to 512,000
Forwarding Rate Up to 360 Mpps
Input voltage 90 to 264 VAC
Jumbo frame 9198 bytes
Minimum software requirement Open Cisco IOS-XE Software Release 16.8.1
MTBF (Hours) 315,790
NEBS criteria levels NEBS:•Normal operating temperature range: 5C to 40C (up to 1829 meters (6000 ft)•Short term operating temperature range: -5C to 55C•Normal Relative Humidity range: 5% to 85%•Short term Relative Humidity range: 5% to 93%•Operating Altitude: up to 1829 m (6000 ft) at 55C•ETSI 300-019 Requirements are covered under GR-63-CORE with some deviations.•SR-3580 NEBS level 3 (GR-63-CORE, to current issue, GR-1089-CORE, to current issue
Operating Temperature 32°to 104°F (0°to 40°C)
Product Code C9500-16X-EDU
Product Description Catalyst 9500 16-port 10G, K12
QoS ACL scale Up to 18000
Rack Units (RU) 1 RU
Relative humidity operating and nonoperating noncondensing Ambient (noncondensing) operating: 5% to 90%Ambient (noncondensing) nonoperating and storage: 5% to 95%
Safety Certifications C9500-12Q, C9500-24Q, C9500-40X,C9500-16X•UL 60950-1•CAN/CSA-C22.2 No. 60950-1•EN 60950-1•IEC 60950-1•AS/NZS 60950-1•GB4943C9500-32C, C9500-32QC, C9500-24Y4C, C9500-48Y4C•IEC 60950-1 plus Am1, Am2 Am9, Am10, Am11, Am12 and all deviations and differences•AS/NZS 60950.1.2011•CAN/CSA-C22.2 No. 60950-1-07•GB 4943-95•EN 60950-1; 2006 plus Am1, Am 2, Am9, Am10, Am11, Am12 and all deviations and differences•NOM-019-SCFI-1998•UL 60950-1, Second Edition
Security ACL scale Up to 18000
Storage temperature -4°to 149°F (-20°to 65°C)
Switching capacity Up to 480 Gbps
Total number of IPv4 Multicast routes Up to 32,000
Total number of IPv4 routes (Address Resolution Protocol [ARP] p Up to 64,000 indirectUp to 80,000 host
Total number of IPv6 Multicast routes Up to 16,000
Total number of IPv6 routes Up to 32,000 indirectUp to 40,000 host
Total number of MAC addresses Up to 64,000
Total Switched Virtual Interfaces (SVIs) 4000
VLAN IDs 4094
  Написать отзыв