+7 (812) 309 34 73. Договоримся!
Общая информация (WS-C2960+48PST-S)
Cisco Catalyst WS-C2960+48PST-S is a LAN Lite switch that provides 48 x 10/100 PoE Ethernet ports, 2 x 1000BT and 2 x SFP uplink interfaces.
Быстрые спецификацииs
На рисунке 1 показан внешний вид WS-C2960+48PST-S.
Таблица 1 показывает Быстрые спецификацииs.
Product Code |
WS-C2960+48PST-S |
Enclosure Type |
Rack-mountable 1U |
Feature Set |
LAN Lite |
Uplink Interfaces |
2 x SFP and 2 x 1000BASE-T |
Ports |
48 x 10/100 Ethernet Ports |
Available PoE Power |
370W |
Maximum Number of PoE (IEEE 802.3af) Ports |
24 ports up to 15.4W |
Forwarding Bandwidth |
16 Gbps |
RAM |
128MB |
Flash Memory |
64MB |
Dimensions |
4.4cm x 45.0cm x 33.2cm |
Package Weight |
9.19 Kg |
Детали продукта
На рисунке 2 показана передняя панель WS-C2960+48PST-S.
Note:
? Switch LEDs ? Mode Button ? 10/100 PoE ports ? 10/100/1000 uplink ports ? SFP module slots
·The Switch LEDs include SYST, RPS, Status, PoE, Duplex and Speed LED.
·10/100 PoE ports mean that Ports 1 to 48 on the switch are PoE ports
·Each of the PoE ports deliver up to 15.4 W of PoE.
На рисунке 3 показана задняя панель WS-C2960+48PST-S.
Note:
? RJ-45 console port ? Fan exhaust ? RPS connector ? AC power connector
Аксессуары
Table 2 shows Аксессуары of WS-C2960+48PST-S.
Models |
Description |
CAB-CONSOLE-RJ45 |
Console Cable 6ft with RJ45 and DB9F |
GLC-SX-MMD |
1000BASE-SX SFP transceiver module, MMF, 850nm, DOM |
GLC-LH-SM |
GE SFP, LC connector LX/LH transceiver |
Datasheet Download
Cisco Switch Catalyst 2960-Plus Series Datasheet.pdf
Что бы получить больше информации
У вас есть какие-либо вопросы о Cisco C2960+48PST-S switch?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
10/100 Ethernet Interfaces | 48 |
Uplink Interfaces | 2 SFP and 2 1000BASE-T |
Cisco IOS Software Feature Set | LAN Lite |
Flash memory | 64 MB |
Forwarding bandwidth | 16 Gbps |
VLAN IDs available | 4K |
Maximum transmission unit (MTU) - L3 packet | 9000 bytes |
Jumbo frame - Ethernet frame | 9018 bytes |
Forwarding Rate: 64-Byte L3 Packets, Millions of packets per sec | 13.1 |
Maximum active VLANs | 64 |
Sound Pressure, dBA | Typical, LpAm: 41<BR>Maximum, LpAD: 44 |
Sound Power, dbA | Typical, LwA: 51<BR>Maximum, LwAD: 54 |
MTBF in thousands of hours | 312 |
Ethernet Interfaces | 10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 unshielded twisted-pair (UTP) cabling<BR>100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling<BR>1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling<BR>1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
Indicator LEDs | Per-port status: Link integrity, disabled, activity, speed, and full duplex<BR>System status, Port Status, PoE, RPS, link duplex, and link speed |
Console | Cisco Catalyst console cables:<BR>CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45 |
Standards | IEEE 802.1D Spanning Tree Protocol<BR>IEEE 802.1p CoS Prioritization<BR>IEEE 802.1Q VLAN<BR>IEEE 802.1s<BR>IEEE 802.1w<BR>IEEE 802.1X<BR>IEEE 802.1ab (LLDP)<BR>IEEE 802.3ad<BR>IEEE 802.3af<BR>IEEE 802.3ah (100BASE-X single/multimode fiber only)<BR>IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports<BR>IEEE 802.3 10BASE-T<BR>IEEE 802.3u 100BASE-TX<BR>IEEE 802.3ab 1000BASE-T<BR>IEEE 802.3z 1000BASE-X<BR>RMON I and II standards<BR>SNMP v1, v2c, and v3 |
RFC compliance | RFC 768 - UDP<BR>RFC 783 - TFTP<BR>RFC 791 - IP<BR>RFC 792 - ICMP<BR>RFC 793 - TCP<BR>RFC 826 - ARP<BR>RFC 854 - Telnet<BR>RFC 951 - Bootstrap Protocol (BOOTP)<BR>RFC 959 - FTP<BR>RFC 1112 - IP Multicast and IGMP<BR>RFC 1157 - SNMP v1<BR>RFC 1166 - IP Addresses<BR>RFC 1256 - Internet Control Message Protocol (ICMP) Router Discovery<BR>RFC 1305 - NTP<BR>RFC 1492 - TACACS+<BR>RFC 1493 - Bridge MIB<BR>RFC 1542 - BOOTP extensions<BR>RFC 1643 - Ethernet Interface MIB<BR>RFC 1757 - RMON<BR>RFC 1901 - SNMP v2C<BR>RFC 1902-1907 - SNMP v2<BR>RFC 1981 - Path MTU Discovery for IPv6<BR>FRC 2068 - HTTP<BR>RFC 2131 - DHCP<BR>RFC 2138 - RADIUS<BR>RFC 2233 - IF MIB v3<BR>RFC 2373 - IPv6 Aggregatable Addrs<BR>RFC 2460 - IPv6<BR>RFC 2461 - IPv6 Neighbor Discovery<BR>RFC 2462 - IPv6 Autoconfiguration<BR>RFC 2463 - ICMP IPv6<BR>RFC 2474 - Differentiated Services (DiffServ) Precedence<BR>RFC 2597 - Assured Forwarding<BR>RFC 2598 - Expedited Forwarding<BR>RFC 2571 - SNMP Management<BR>RFC 3046 - DHCP Relay Agent Information Option<BR>RFC 3376 - IGMP v3<BR>RFC 3580 - 802.1X RADIUS |
Voltage (Autoranging) | 100 to 240 VAC |
Current (Amperes) | 4.0 - 2.0 |
Frequency | 50 to 60Hz |
Power Rating (kVA) | 0.46 |
DC Input Voltages (RPS Input) | 3A at 12V (7A at -52V) |
Short-term exception at sea level* | 23 to 131 F<BR>(-5 to 55 C) |
Dimensions (H x W x D) | 1.73 x 17.70 x 13.07 in (4.4 x 45.0 x 33.2 cm) |
Power Consumption | 0% traffic: 50.8<BR>10% traffic: 50.3<BR>100% traffic: 51.1<BR>ATIS weighted average: 50.5 |
Package Weight | 20.26 lb (9.19 Kg) |
Short-term exception up to 5000 feet (1500 m)* | 23 to 122 F<BR>(-5 to 50 C) |
Regulatory Compliance | Products should comply with CE Marking per directives 2004/108/EC and 2006/95/EC |
Management | BRIDGE-MIB<BR>CISCO-CABLE-DIAG-MIB<BR>CISCO-CDP-MIB<BR>CISCO-CLUSTER-MIB<BR>CISCO-CONFIG-COPY-MIB<BR>CISCO-CONFIG-MAN-MIB<BR>CISCO-DHCP-SNOOPING-MIB<BR>CISCO-ENTITY-VENDORTYPE-OID-MIB<BR>CISCO-ENVMON-MIB<BR>CISCO-ERR-DISABLE-MIB<BR>CISCO-FLASH-MIB<BR>CISCO-FTP-CLIENT-MIB<BR>CISCO-IGMP-FILTER-MIB<BR>CISCO-IMAGE-MIB<BR>CISCO-IP-STAT-MIB<BR>CISCO-LAG-MIB<BR>CISCO-MAC-NOTIFICATION-MIB<BR>CISCO-MEMORY-POOL-MIB<BR>CISCO-PAGP-MIB<BR>CISCO-PING-MIB<BR>CISCO-POE-EXTENSIONS-MIB<BR>CISCO-PORT-QOS-MIB<BR>CISCO-PORT-SECURITY-MIB<BR>CISCO-PORT-STORM-CONTROL-MIB<BR>CISCO-PRODUCTS-MIB<BR>CISCO-PROCESS-MIB<BR>CISCO-RTTMON-MIB<BR>CISCO-SMI-MIB<BR>CISCO-STP-EXTENSIONS-MIB<BR>CISCO-SYSLOG-MIB<BR>CISCO-TC-MIB<BR>CICSO-TCP-MIB<BR>CISCO-UDLDP-MIB<BR>CISCO-VLAN-IFTABLE<BR>RELATIONSHIP-MIB<BR>CISCO-VLAN-MEMBERSHIP-MIB<BR>CISCO-VTP-MIB<BR>ENTITY-MIB<BR>ETHERLIKE-MIB<BR>IEEE8021-PAE-MIB<BR>IEEE8023-LAG-MIB<BR>IF-MIB<BR>INET-ADDRESS-MIB<BR>OLD-CISCO-CHASSIS-MIB<BR>OLD-CISCO-FLASH-MIB<BR>OLD-CISCO-INTERFACES-MIB<BR>OLD-CISCO-IP-MIB<BR>OLD-CISCO-SYS-MIB<BR>OLD-CISCO-TCP-MIB<BR>OLD-CISCO-TS-MIB<BR>RFC1213-MIB<BR>RMON-MIB<BR>RMON2-MIB<BR>SNMP-FRAMEWORK-MIB<BR>SNMP-MPD-MIB<BR>SNMP-NOTIFICATION-MIB<BR>SNMP-TARGET-MIB<BR>SNMPv2-MIB<BR>TCP-MIB<BR>UDP-MIB<BR>ePM MIB |
Short-term exception up to 10,000 feet (3000 m)* | 23 to 113 F<BR>(-5 to 45 C) |
Short-term exception up to 13,000 feet (4000 m)* | 23 to 104 F<BR>(-5 to 40 C) |
EMC - Emissions | 47CFR Part 15 (CFR 47) Class A<BR>AS/NZS CISPR22 Class A<BR>CISPR22 Class A<BR>EN55022 Class A<BR>ICES003 Class A<BR>VCCI Class A<BR>EN61000-3-2<BR>EN61000-3-3<BR>KN22 Class A<BR>CNS13438 Class A |
Operating temperature up to 5000 ft (1500 m) | 23 to 113 F<BR>(-5 to 45 C) |
Storage temperature up to 15,000 feet (4573 m) | 23 to 158 F<BR>(-25 to 70 C) |
EMC - Immunity | EN55024<BR>CISPR24<BR>EN300386<BR>KN24 |
Environmental | Reduction of Hazardous Substances (RoHS) including Directive 2011/65/EU |
Safety | UL 60950-1 Second Edition<BR>CAN/CSA-C22.2 No. 60950-1 Second Edition<BR>EN 60950-1 Second Edition<BR>IEC 60950-1 Second Edition<BR>AS/NZS 60950-1 |
Operating temperature up to 10,000 ft (3000 m) | 23 to 104 F<BR>(-5 to 40 C) |
Operating altitude | Up to 10,000 Feet<BR>(Up to 3,000 Meters) |
Storage altitude | Up to 13,000 Feet<BR>(Up to 4,000 Meters) |
Operating relative humidity | 10% to 95% noncondensing |
Storage relative humidity | 10% to 95% noncondensing |
Available PoE Power | 370W (24 ports up to 15.4W) |
DRAM | 128 MB |
Weight | 12 lb (5.4Kg) |
Power | The internal power supply is an auto-ranging unit and supports input voltages between 100 and 240V AC.<BR>Use the supplied AC power cord to connect the AC power connector to an AC power outlet.<BR>The Cisco RPS connector offers connection for an optional Cisco RPS 2300 that uses AC input and supplies DC output to the switch.<BR>Only the Cisco RPS 2300 (model PWR-RPS2300) should be attached to the redundant-power-system receptacle. |
Теги: WS-C2960+48PST-S