+7 (812) 309 34 73. Договоримся!
N9K-C9504 is the Nexus 9504 Chassis with 8 line card slots. The Cisco Nexus 9500 platform, part of the Cisco Nexus 9000 Series, offers three modular options: the Cisco Nexus 9504 Switch with 4 slots, the Cisco Nexus 9508 Switch with 8 slots, and the Cisco Nexus 9516 Switch with 16 slots. All three switches use the same supervisor, system controller, power supplies, and line cards. The Cisco Nexus 9500 platform consists of Layer 2 and 3 nonblocking Ethernet switches with backplane bandwidth of up to 115.2 Terabits per second (Tbps). The Cisco Nexus 9504, 9508, and 9516 Switches support 1, 10, 25, 40, 50, and 100 Gigabit Ethernet interfaces through a comprehensive selection of modular line cards. Configurable with up to 2304 x 10 Gigabit Ethernet ports, 2048 x 25 Gigabit Ethernet ports, 576 x 40 Gigabit Ethernet ports, 1024 x 50 Gigabit Ethernet ports, or 512 x 100 Gigabit Ethernet ports, they provide ample capacity for both access- and aggregation-layer deployments.
Quick Specs
Table 1 shows the Quick Specs.
Product Code |
N9K-C9504 |
Chassis |
● Up to 4 line cards ● Up to 4 power supplies ● Up to 6 fabric modules ● Up to 2 system controllers ● Up to 2 supervisors ● Up to 3 fan trays |
Physical (H x W x D) |
12.25 x 17.50 x 33.15 in. (31.1 x 44.50 x 84.20 cm) |
Weight (chassis) |
84 lb (38.2 kg) |
Product Details
Figure 1 shows the front panel of N9K-C9504. The modules and cards in it need to be purchased separately.
Note: ① Line cards (up to 4) ② Supervisor modules (1 or 2) ③ 3-kW AC power supplies (up to two without power redundancy or up to four with power redundancy) in slots PS 1 to PS 4 (AC power supplies shown).
*The back panel have these things:
① Fan trays
② Grounding pad
③ Fabric modules
④ Chassis handles
⑤ System controllers
The Modules
Table 2 shows the supported accessories.
Model |
Description |
N9K-SUP-B+ |
Nexus 9500 6-Core/12-Thread Supervisor |
N9K-SUP-B |
Nexus 9500 6-Core/12-Thread Supervisor |
N9K-SC-A |
Nexus 9500 System Controller |
N9K-PAC-3000W-B |
Nexus 9500 3000W 200V to 240V AC AC PS, Port Side Intake |
N9K-PDC-3000W-B |
Nexus 9500 3000W -48V-60V DC PS, Port Side Intake |
N9K-PUV-3000W-B |
Nexus 9500 3000W 200V to 277V AC or 240V to 380V DC Universal high voltage AC/DC PS, Port Side Intake |
Compare to Similar Items
Table 3 shows the comparison.
Product Code |
N9K-C9508 |
N9K-C9504 |
Chassis |
● Up to 8 line cards ● Up to 8 power supplies ● Up to 6 fabric modules ● Up to 2 system controllers ● Up to 2 supervisors ● Up to 3 fan trays |
● Up to 4 line cards ● Up to 4 power supplies ● Up to 6 fabric modules ● Up to 2 system controllers ● Up to 2 supervisors ● Up to 3 fan trays |
Physical (H x W x D) |
22.70 x 17.50 x 31.76 in. (57.78 x 44.50 x 80.67 cm) |
12.25 x 17.50 x 33.15 in. (31.1 x 44.50 x 84.20 cm) |
Weight (chassis) |
150 lb (68.2 kg) |
84 lb (38.2 kg) |
Get More Information
Do you have any question about the Cisco N9K-C9504?
Contact us now via Live Chat or info@itg-spb.ru.
N9K-C9504 Specification |
|
Chassis |
● Up to 4 line cards ● Up to 4 power supplies ● Up to 6 fabric modules ● Up to 2 system controllers ● Up to 2 supervisors ● Up to 3 fan trays |
Physical (H x W x D) |
12.25 x 17.50 x 33.15 in. (31.1 x 44.50 x 84.20 cm) |
Weight (chassis) |
84 lb (38.2 kg) |
Operating temperature |
32 to 104°F (0 to 40°C) |
Nonoperating (storage) temperature |
-40 to 158°F (-40 to 70°C) |
Humidity |
5 to 95% (noncondensing) |
Altitude |
0 to 13,123 ft (0 to 4000m) |
MTBF (Hours) |
Chassis: 1,038,080 |
Regulatory compliance |
Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC |
Safety |
● UL 60950-1 Second Edition ● CAN/CSA-C22.2 No. 60950-1 Second Edition ● EN 60950-1 Second Edition ● IEC 60950-1 Second Edition ● AS/NZS 60950-1 ● GB4943 |
EMC: Emissions |
● 47CFR Part 15 (CFR 47) Class A ● AS/NZS CISPR22 Class A ● CISPR22 Class A ● EN55022 Class A ● ICES003 Class A ● VCCI Class A ● EN61000-3-2 ● EN61000-3-3 ● KN22 Class A ● CNS13438 Class A |
EMC: Immunity |
● EN55024 ● CISPR24 ● EN300386 ● KN 61000-4 series |
RoHS |
The product is RoHS-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. |
Характеристики | |
Altitude | 0 to 13,123 ft (0 to 4000m) |
Chassis | ● Up to 4 line cards● Up to 4 power supplies● Up to 6 fabric modules● Up to 2 system controllers● Up to 2 supervisors● Up to 3 fan trays |
EMC: Emissions | ● 47CFR Part 15 (CFR 47) Class A● AS/NZS CISPR22 Class A● CISPR22 Class A● EN55022 Class A● ICES003 Class A● VCCI Class A● EN61000-3-2● EN61000-3-3● KN22 Class A● CNS13438 Class A |
EMC: Immunity | ● EN55024● CISPR24● EN300386● KN 61000-4 series |
Humidity | 5 to 95% (noncondensing) |
MTBF (Hours) | Chassis: 1,038,080 |
Nonoperating (storage) temperature | -40 to 158°F (-40 to 70°C) |
Operating Temperature | 32 to 104°F (0 to 40°C) |
Physical (H x W x D) | 12.25 x 17.50 x 33.15 in. (31.1 x 44.50 x 84.20 cm) |
Regulatory Compliance | Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC |
RoHS | The product is RoHS-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors. |
Safety | ● UL 60950-1 Second Edition● CAN/CSA-C22.2 No. 60950-1 Second Edition● EN 60950-1 Second Edition● IEC 60950-1 Second Edition● AS/NZS 60950-1● GB4943 |
Weight (chassis) | 84 lb (38.2 kg) |