The Cisco Nexus® 3164Q Switch is an ultra-high density, power efficient, 10/40-Gbps switch designed for the data center. This compact, two-rack-unit (2RU) model offers wire-rate Layer 2 and Layer 3 switching on all ports. It runs the enhanced version of the Cisco® NX-OS Software operating system, that also supports Nexus 9000 series switches.
Quick Specs
Table 1 shows the Quick Specs.
Product Code |
N3K-C3164Q-2PK |
Product Description |
2 x Nexus 3164Q bundle |
Dimensions (H x W x D) |
3.48 x 17.41 x 22.32in. (88.4 x 442 x 566 mm) |
Number of VLANS |
MSTP: 4096 |
Number of spanning-tree instances |
MSTP: 64 RPVST+: 507 |
Number of EtherChannels |
256 |
Number of ports per EtherChannel |
32 |
Buffer size |
48 MB shared |
System memory |
16 GB |
Product Details
The Cisco Nexus 3164Q provides these highlights:
•Wire-rate Layer 2 and 3 switching on all ports up to 5.12 terabits per second (Tbps) and up to 3.8 billion packets per second (bpps).
•Rich Programmability, with support for NX-API, Linux Containers, XML/JavaScript Object Notation (JSON) APIs, Openstack plugin, Python, and Puppet/Chef configuration and automation tools.
•High Performance and Scalability with 6 core CPU, 16GE DRAM and 64 GB SSD, with 48 Mbytes of dynamic buffer allocation. Ideal for massively scalable data centers and big data applications.
•Flexibility
-The QSFP port can be configured to work as four 10-Gbps ports, offering deployment flexibility, up to a maximum of 256 10G ports.
-The Cisco® Quad Small Form-Factor (QSFP) 40-Gbps Bidirectional (BiDi) Transceiver technology allows the reuse of existing 10G cablings, a smooth transition from 10 to 40 Gigabit Ethernet infrastructures in data centers.
-Both fiber and copper cabling solutions for both 10-Gbps and 40-Gbps, with the SFP options of Bidi, AOC, SR4 fiber optics.
•High availability
-Virtual PortChannel (vPC) technology provides Layer 2 multipathing through the elimination of Spanning Tree Protocol. It also enables fully utilized bisectional bandwidth and simplified Layer 2 logical topologies without the need to change the existing management and deployment models.
-The 64-way equal-cost multipath (ECMP) routing enables the use of Layer 3 fat-tree designs. This allows organizations to prevent network bottlenecks, increase resiliency, and add capacity with little network disruption.
-Advanced reboot capabilities include hot/cold pathching and Fast Reboot capabilities.
-Hot swappable power-supply units (PSUs) and fans.
•Purpose-built Cisco NX-OS operating system with comprehensive, proven innovations
-PowerOn Auto Provisioning (POAP) enables touchless bootup and configuration of the switch, drastically reducing provisioning time.
-Cisco Embedded Event Manager (EEM) and Python scripting enable automation and remote operations in the data center.
-Advanced buffer monitoring reports real-time buffer utilization per port and per queue, which allows organizations to monitor traffic bursts and application traffic patterns.
-EtherAnalyzer is a built-in packet analyzer for monitoring and troubleshooting control-plane traffic and is based on the popular Wireshark open source network protocol analyzer.
-Complete Layer 3 unicast and multicast routing protocol suites are supported, including Border Gateway Protocol (BGP), Open Shortest Path First (OSPF), Enhanced Interior Gateway Routing Protocol (EIGRP), Routing Information Protocol Version 2 (RIPv2), Protocol Independent Multicast sparse mode (PIM-SM), Source-Specific Multicast (SSM), and Multicast Source Discovery Protocol (MSDP).
The Accessories
Table 2 shows the supported accessories.
Model |
Description |
QSFP-40G-SR-BD |
Cisco QSFP40G BiDi Short-reach Transceiver |
QSFP-H40G-AOC1M |
QSFP 40G Active Optical Cable 1m |
QSFP-H40G-AOC2M |
QSFP 40G Active Optical Cable 2m |
QSFP-H40G-AOC3M |
QSFP 40G Active Optical Cable 3m |
QSFP-H40G-AOC5M |
QSFP 40G Active Optical Cable 5m |
QSFP-H40G-AOC7M |
QSFP 40G Active Optical Cable 7m |
QSFP-H40G-AOC10M |
QSFP 40G Active Optical Cable 10m |
QSFP-4X10G-AOC1M |
QSFP to 4 x SFP 10Gbps Active Optical Cable 1m |
QSFP-4X10G-AOC2M |
QSFP to 4 x SFP 10Gbps Active Optical Cable 2m |
QSFP-4X10G-AOC3M |
QSFP to 4 x SFP 10Gbps Active Optical Cable 3m |
QSFP-4X10G-AOC5M |
QSFP to 4 x SFP 10Gbps Active Optical Cable 5m |
QSFP-4X10G-AOC7M |
QSFP to 4 x SFP 10Gbps Active Optical Cable 7m |
QSFP-4X10G-AOC10M |
QSFP to 4 x SFP 10Gbps Active Optical Cable 10m |
QSFP-4SFP10G-CU5M |
QSFP to 4 x SFP 10-Gbps passive copper splitter cable, 5m |
QSFP-4SFP10G-CU3M |
QSFP to 4 x SFP 10-Gbps passive copper splitter cable, 3m |
QSFP-4SFP10G-CU1M |
QSFP to 4 x SFP 10-Gbps passive copper splitter cable, 1m |
QSFP-H40G-CU3M |
40GBASE-CR4 passive copper cable, 3m |
QSFP-H40G-CU1M |
40GBASE-CR4 passive copper cable, 1m |
QSFP-40G-SR4 |
40GBASE-SR4 QSFP transceiver module with MPO connector |
QSFP-40G-CSR4 |
40GBASE-CSR4 QSFP+ transceiver module for MMF, MPO/MTP connector, 300 m reach with OM3 fiber |
QSFP-40GE-LR4 |
40GBASE-LR4 QSFP+ transceiver module for SMF, 4 CWDM lanes in 1310 nm window Muxed inside module, duplex LC connector, 10 km reach |
N9K-C9300-FAN3 |
Nexus 3164 Fan Module, Port side intake |
N9K-PAC-1200W |
Nexus 3164 1200W AC Power Supply, Port side intake |
L-N3K-LAN1K9= |
Nexus 3000 LAN Enterprise License, eDelivery |
Compare to Similar Items
Table 3 shows the comparison.
Product Code |
N3K-C3264Q |
N3K-C3164Q-2PK |
Description |
Nexus 3264Q, 64 QSFP+ ports, 2RU switch |
Nexus 3164Q, 64 QSFP+ ports, 2RU switch |
Physical dimensions |
3.39 x 17.41 x 22.32 in. (88.4 x 442 x 566 mm) |
3.48 x 17.41 x 22.32in. (88.4 x 442 x 566 mm) |
Frequency |
50 to 60 Hz |
50 to 60 Hz |
Power supply types |
AC |
AC |
Typical operating power |
285 watts (W) |
803 Watts (W) with SR4 optics at 100% load; 2 PSUs |
Maximum power |
715 W |
1100 W |
Get More Information
Do you have any question about the N3K-C3164Q-2PK?
Contact us now via Live Chat or info@itg-spb.ru.
N3K-C3164Q-2PK Specification |
|||
Physical
|
•2 RU fixed form-factor switch •64 QSFP+ ports; each supports native 40 Gigabit Ethernet and 4 x 10 Gigabit Ethernet modes •2 redundant power supplies •3+1 redundant fans •Management, console, and USB flash-memory ports |
||
Performance
|
•5.12 Tbps switching capacity •Forwarding rate up to 3.8 bpps •Line-rate traffic throughput (both Layer 2 and 3) on all ports •Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
||
Hardware tables and scalability |
|||
Number of VLANS |
MSTP: 4096 |
||
Number of spanning-tree instances |
MSTP: 64 RPVST+: 507 |
||
Number of access control list (ACL) entries |
4000 to 16000 ingress 1000 to 4000 egress |
||
Routing table |
Maximum number of longest prefix match (LPM) routes 128,000 Maximum number of IP host entries 120,000 Maximum number of MAC address entries 96,000 |
||
Number of EtherChannels |
256 |
||
Number of ports per EtherChannel |
32 |
||
Buffer size |
48 MB shared |
||
System memory |
16 GB |
||
Number of spanning-tree instances |
MSTP: 64 RPVST+: 507 |
||
Hardware tables and scalability |
|||
Number of spanning-tree instances |
MSTP: 64 RPVST+: 507 |
||
Number of access control list (ACL) entries |
4000 to 16000 ingress 1000 to 4000 egress |
||
Routing table |
Maximum number of longest prefix match (LPM) routes 128,000 Maximum number of IP host entries 120,000 Maximum number of MAC address entries 96,000 |
||
Number of EtherChannels |
256 |
||
Number of ports per EtherChannel |
32 |
||
Buffer size |
48 MB shared |
||
System memory |
16 GB |
||
Power |
|||
Frequency |
50 to 60 Hz |
||
Power supply types |
AC |
||
Typical operating power |
803 Watts (W) with SR4 optics at 100% load; 2 PSUs |
||
Maximum power |
1100 Watts (W) |
||
AC PSUs •Input voltage •Frequency •Efficiency |
•200 to 240 VAC •50 to 60 Hz •93% at 220V |
||
Typical heat dissipation |
2739 BTU/hr (with SR4 optics at 100% load) |
||
Maximum heat dissipation |
3753 BTU/hr |
||
Cooling |
Port-side intake and port-side exhaust options Port-side intake: Yes Port-side exhaust: Post FCS |
||
Dimensions (height x width x depth) |
3.48 x 17.41 x 22.32in. (88.4 x 442 x 566 mm) |
||
Environment |
|||
Operating temperature |
32 to 104°F (0 to 40°C) |
||
Storage temperature |
-40 to 158°F (-40 to 70°C) |
||
Operating relative humidity |
•10 to 85% noncondensing •Up to 5 days at maximum (85%) humidity Recommend ASHRAE data center environment |
||
Storage relative humidity |
5% to 95% noncondensing |
||
Altitude |
0 to 10,000 ft (0 to 3000m) |
||
Software Features |
|||
Maximum number of longest prefix match (LPM) routes |
128,000 |
||
Maximum number of IP host entries |
120,000 |
||
Maximum number of MAC address entries |
96,000 |
||
Number of multicast routes |
16,000, up to 60,000 |
||
Number of Interior Gateway Management Protocol (IGMP) snooping groups |
8,000, up to 60,000 |
||
Number of access control list (ACL) entries |
1000 to 4000 egress 4000 to 16000 ingress |
||
Maximum number of VLANs |
4000 |
||
Maximum number of Virtual Routing and Forwarding (VRF) instances |
1000 |
||
Maximum number of links in a PortChannel |
32 |
||
Maximum number of ECMP paths |
64 |
||
Maximum number of PortChannels |
256 |
||
Number of active Switched Port Analyzer (SPAN) sessions |
4 |
||
Maximum number of Rapid per-VLAN Spanning Tree (RPVST) instances |
507 |
||
Maximum number of Hot Standby Router Protocol (HSRP) groups |
490 |
||
Maximum number of Multiple Spanning Tree (MST) instances |
64 |
||
Maximum number of tunnel endpoints (VTEP) and VXLAN physical servers (per VLAN) |
10,000 |
||
Regulatory Standards Compliance: Safety and EMC |
|||
Regulatory compliance |
•Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC |
||
Safety |
•UL 60950-1 Second Edition •CAN/CSA-C22.2 No. 60950-1 Second Edition •EN 60950-1 Second Edition •IEC 60950-1 Second Edition •AS/NZS 60950-1 •GB4943 |
||
EMC: Emissions |
•47CFR Part 15 (CFR 47) Class A •AS/NZS CISPR22 Class A •CISPR22 Class A •EN55022 Class A •ICES003 Class A •VCCI Class A •EN61000-3-2 •EN61000-3-3 •KN22 Class A •CNS13438 Class A |
||
EMC: Immunity |
•EN55024 •CISPR24 •EN300386 •KN24 |
Характеристики | |
10,000 | Regulatory Standards Compliance: Safety and EMC |
1000 | Maximum number of links in a PortChannel |
1000 to 4000 egress4000 to 16000 ingress | Maximum number of VLANs |
1100 Watts (W) | AC PSUs•Input voltage•Frequency•Efficiency |
120,000 | Maximum number of MAC address entries |
128,000 | Maximum number of IP host entries |
16 GB | Number of spanning-tree instances |
16,000, up to 60,000 | Number of Interior Gateway Management Protocol (IGMP) snooping groups |
256 | Number of active Switched Port Analyzer (SPAN) sessions |
2739 BTU/hr (with SR4 optics at 100% load) | Maximum heat dissipation |
3.48 x 17.41 x 22.32in. (88.4 x 442 x 566 mm) | Environment |
32 | Maximum number of ECMP paths |
3753 BTU/hr | Cooling |
4 | Maximum number of Rapid per-VLAN Spanning Tree (RPVST) instances |
4000 | Maximum number of Virtual Routing and Forwarding (VRF) instances |
4000 to 16000 ingress1000 to 4000 egress | Routing table |
48 MB shared | System memory |
490 | Maximum number of Multiple Spanning Tree (MST) instances |
50 to 60 Hz | Power supply types |
507 | Maximum number of Hot Standby Router Protocol (HSRP) groups |
64 | Maximum number of tunnel endpoints (VTEP) and VXLAN physical servers (per VLAN) |
8,000, up to 60,000 | Number of access control list (ACL) entries |
803 Watts (W) with SR4 optics at 100% load; 2 PSUs | Maximum power |
96,000 | Number of multicast routes |
AC | Typical operating power |
Altitude | 0 to 10,000 ft (0 to 3000m) |
Buffer size | 48 MB shared |
EMC: Emissions | •47CFR Part 15 (CFR 47) Class A•AS/NZS CISPR22 Class A•CISPR22 Class A•EN55022 Class A•ICES003 Class A•VCCI Class A•EN61000-3-2•EN61000-3-3•KN22 Class A•CNS13438 Class A |
EMC: Immunity | •EN55024•CISPR24•EN300386•KN24 |
Hardware tables and scalability | Number of VLANS |
Maximum number of longest prefix match (LPM) routes 128,000Maxim | Number of EtherChannels |
MSTP: 4096 | Number of spanning-tree instances |
MSTP: 64RPVST+: 507 | Hardware tables and scalability |
Number of access control list (ACL) entries | 4000 to 16000 ingress1000 to 4000 egress |
Number of EtherChannels | 256 |
Number of ports per EtherChannel | 32 |
Number of spanning-tree instances | MSTP: 64RPVST+: 507 |
Operating Relative Humidity | •10 to 85% noncondensing•Up to 5 days at maximum (85%) humidityRecommend ASHRAE data center environment |
Operating Temperature | 32 to 104°F (0 to 40°C) |
Performance | •5.12 Tbps switching capacity•Forwarding rate up to 3.8 bpps•Line-rate traffic throughput (both Layer 2 and 3) on all ports•Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
Physical | •2 RU fixed form-factor switch•64 QSFP+ ports; each supports native 40 Gigabit Ethernet and 4 x 10 Gigabit Ethernet modes•2 redundant power supplies•3+1 redundant fans•Management, console, and USB flash-memory ports |
Port-side intake and port-side exhaust optionsPort-side intake: | Dimensions (height x width x depth) |
Power | Frequency |
Regulatory Compliance | •Products should comply with CE Markings per directives 2004/108/EC and 2006/95/EC |
Routing table | Maximum number of longest prefix match (LPM) routes 128,000Maximum number of IP host entries 120,000Maximum number of MAC address entries 96,000 |
Safety | •UL 60950-1 Second Edition•CAN/CSA-C22.2 No. 60950-1 Second Edition•EN 60950-1 Second Edition•IEC 60950-1 Second Edition•AS/NZS 60950-1•GB4943 |
Software features | Maximum number of longest prefix match (LPM) routes |
Storage relative humidity | 5% to 95% noncondensing |
Storage temperature | -40 to 158°F (-40 to 70°C) |
System memory | 16 GB |
•200 to 240 VAC •50 to 60 Hz•93% at 220V | Typical heat dissipation |
Теги: N3K-C3164Q-2PK Cisco