Общая информация (WS-C3560CX-8PC-S)
WS-C3560CX-8PC-S compact enterprise class layer 3 switch offers 8-port Gigabit Ethernet data POE+ models. This switch support both 2 x 1 Gigabit copper and 2 x 1 Gigabit SFP uplinks.
Быстрые спецификацииs
На рисунке 1 показан внешний вид WS-C3560CX-8PC-S.
Таблица 1 показывает Быстрые спецификацииs.
Product Code |
WS-C3560CX-8PC-S |
Feature Set |
IP Base |
Uplink Interfaces |
2 Gigabit Ethernet RJ-45 uplinks, 2 SFP upliks |
Ports |
8 x Gigabit Ethernet ports |
Forwarding Bandwidth |
16 Gbps |
Switching Bandwidth (full-duplex capacity) |
32 Gbps |
Available POE Power |
240W |
RAM |
512 MB |
Flash Memory |
128 MB |
Dimensions |
4.44 x 26.9 x 23.8 cm |
Package Weight |
4.65 kg |
Детали продукта
На рисунке 2 показана передняя панель WS-C3560CX-8PC-S.
Note:
? |
Mode button |
? |
SFP module slots |
? |
USB Type A port |
? |
12 x 10/100/1000 ports |
? |
USB mini-Type B (console) port |
? |
Switch LEDs |
? |
2 x 1G copper |
? |
RJ-45 Console Port |
·Switch LEDs include SYST, STAT, SPEED, POE LEDs and Console LED.
Table 2 shows the three LEDs descriptions.
LED |
Color/Port Mode |
Description |
SYST (System LED) |
Off |
System is not powered on. |
Green |
System is operating normally. |
|
Amber |
System is receiving power but is not operating properly. |
|
STAT |
Port status |
The port status. This is the default mode. |
SPEED |
Port speed |
The port operating speed: 10, 100,1000 Mb/s. |
POE |
Off |
PoE is not enabled. |
Green |
PoE is enabled. Ports are functioning correctly. |
|
Blinking Amber |
· PoE mode is not selected · At least one of the 10/10010/100/100 PoE ports has been denied power · At least one of the ports has a PoE fault |
The console LEDs show which console port is in use.
If you connect a cable to a console port, the switch automatically uses that port for console communication. If you connect two console cables, the USB-mini console port has priority.
Table 3 shows the Console LED description.
LED |
Color |
Description |
RJ-45 console port |
Green |
RJ-45 console port is active. USB-mini console port LED is not active. |
Off |
Port is not active. USB-mini console port is active. |
|
USB-mini console port |
Green |
USB-mini console port is active. RJ-45 console port LED is not active. |
Off |
Port is not active. RJ-45 console port is active. |
Аксессуары
Table 4 shows some recommended cables.
Models |
Descriptions |
CAB-CONSOLE-USB |
Cisco CAB-CONSOLE-USB Console Cable 6 ft with USB Type A and mini-B |
CAB-CONSOLE-RJ45 |
Cisco CAB-CONSOLE-RJ45 Console Cable 6ft with RJ45 and DB9F |
Сравнение с аналогом
Models |
WS-C3560CX-12PC-S |
WS-C3560CX-8PC-S |
Uplinks |
2 x 1G copper plus 2 x 1G SFP+ |
2 x 1G copper plus 2 x 1G SFP+ |
Ports |
12 x 10/100/1000 Gigabit Ethernet |
8 x 10/100/1000 Gigabit Ethernet |
Feature set |
IP Base |
IP Base |
PoE Output Ports |
12 PoE+ |
12 PoE+ |
Available POE Power |
240W |
240W |
Что бы получить больше информации
У вас есть какие-либо вопросы о WS-C3560CX-8PC-S?
Свяжитесь с нами через ЧАТ или e-mail: info@itg-spb.ru.
Specification | |
Telco | Common Language Equipment Identifier (CLEI) code |
Maximum transmission unit (MTU) | Up to 9000 bytes |
Dimensions (H x W x D) | 1.75 x 10.6 x 8.4 in (4.44 x 26.9 x 21.3cm) |
MTBF | 569,530 |
Flash memory | 128 MB |
Standards | IEEE 802.1D Spanning Tree Protocol IEEE 802.1p CoS Prioritization IEEE 802.1Q VLAN IEEE 802.1s IEEE 802.1w IEEE 802.1x IEEE 802.1AB (LLDP) IEEE 802.3ad IEEE 802.3af IEEE 802.3ah (100BASE-X single/multimode fiber only) IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports IEEE 802.3 10BASE-T specification IEEE 802.3u 100BASE-TX specification IEEE 802.3ab 1000BASE-T specification IEEE 802.3z 1000BASE-X specification 100BASE-BX (SFP) 100BASE-FX (SFP) 100BASE-LX (SFP) 1000BASE-BX (SFP) 1000BASE-SX (SFP) 1000BASE-LX/LH (SFP) 1000BASE-ZX (SFP) 1000BASE-CWDM SFP 1470 nm 1000BASE-CWDM SFP 1490 nm 1000BASE-CWDM SFP 1510 nm 1000BASE-CWDM SFP 1530 nm 1000BASE-CWDM SFP 1550 nm 1000BASE-CWDM SFP 1570 nm 1000BASE-CWDM SFP 1590 nm 1000BASE-CWDM SFP 1610 nm RMON I and II standards SNMPv1, SNMPv2c, and SNMPv3 |
RFC compliance | RFC 768: UDP RFC 783: TFTP RFC 791: IP RFC 792: ICMP RFC 793: TCP RFC 826: ARP RFC 854: Telnet RFC 951: Bootstrap Protocol RFC 1542: BOOTP Extensions RFC 959: FTP RFC 1058: RIP Routing RFC 1112: IP Multicast and IGMP RFC 1157: SNMPv1 RFC 1166: IP Addresses RFC 1253: OSPF Routing RFC 1256: ICMP Router Discovery RFC 1305: NTP RFC 1492: TACACS+ RFC 1493: Bridge MIB RFC 1542: Bootstrap Protocol RFC 1583: OSPFv2 RFC 1643: Ethernet Interface MIB RFC 1723: RIPv2 Routing RFC 1757: RMON RFC 1812: IP Routing RFC 1901: SNMPv2C RFC 1902-1907: SNMPv2 RFC 1981: MTU Path Discovery IPv6 FRC 2068: HTTP RFC 2080: RIP for IPv6 RFC 2131: DHCP RFC 2138: RADIUS RFC 2233: IF MIB RFC 2236: IP Multicast RFC 2328: OSPFv2 RFC 2273-2275: SNMPv3 RFC 2373: IPv6 Aggregatable Addrs RFC 2453: RIPv2 Routing RFC 2460: IPv6 protocol RFC 2461: IPv6 Neighbor Discovery RFC 2462: IPv6 Autoconfiguration RFC 2463: ICMP IPv6 RFC 2474: DiffServ Precedence RFC 2597: Assured Forwarding RFC 2598: Expedited Forwarding RFC 2571: SNMP Management RFC 2740: OSPF for IPv6 RFC 3046: DHCP Relay Agent Information Option RFC 3101, 1587: NSSAs RFC 3376: IGMPv3 RFC 3580: 802.1x RADIUS |
Management | BRIDGE-MIB CISCO-CABLE-DIAG-MIB CISCO-CDP-MIB CISCO-CLUSTER-MIB CISCO-CONFIG-COPY-MIB CISCO-CONFIG-MAN-MIB CISCO-DHCP-SNOOPING-MIB CISCO-ENTITY-VENDORTYPE-OID-MIB CISCO-ENVMON-MIB CISCO-ERR-DISABLE-MIB CISCO-FLASH-MIB CISCO-FTP-CLIENT-MIB CISCO-IGMP-FILTER-MIB CISCO-IMAGE-MIB CISCO-IP-STAT-MIB CISCO-LAG-MIB CISCO-MAC-NOTIFICATION-MIB CISCO-MEMORY-POOL-MIB CISCO-PAGP-MIB CISCO-PING-MIB CISCO-POE-EXTENSIONS-MIB CISCO-PORT-QOS-MIB CISCO-PORT-SECURITY-MIB CISCO-PORT-STORM-CONTROL-MIB CISCO-PRODUCTS-MIB CISCO-PROCESS-MIB CISCO-RTTMON-MIB CISCO-SMI-MIB CISCO-STP-EXTENSIONS-MIB CISCO-SYSLOG-MIB CISCO-TC-MIB CISCO-TCP-MIB CISCO-UDLDP-MIB CISCO-VLAN-IFTABLE RELATIONSHIP-MIB CISCO-VLAN-MEMBERSHIP-MIB CISCO-VTP-MIB ENTITY-MIB ETHERLIKE-MIB IEEE8021-PAE-MIB IEEE8023-LAG-MIB IF-MIB INET-ADDRESS-MIB OLD-CISCO-CHASSIS-MIB OLD-CISCO-FLASH-MIB OLD-CISCO-INTERFACES-MIB OLD-CISCO-IP-MIB OLD-CISCO-SYS-MIB OLD-CISCO-TCP-MIB OLD-CISCO-TS-MIB RFC1213-MIB RMON-MIB RMON2-MIB SNMP-FRAMEWORK-MIB SNMP-MPD-MIB SNMP-NOTIFICATION-MIB SNMP-TARGET-MIB SNMPv2-MIB TCP-MIB UDP-MIB ePM MIB |
Environmental | Reduction of Hazardous Substances (ROHS) 6 |
Operating altitude | Up to 3048 m (Up to 10,000 ft) |
Storage altitude | Up to 4000 m (Up to 15,000 ft) |
Operating relative humidity | 5% to 95% noncondensing |
Uplinks | 2 x 1G copper plus 2 x 1G SFP |
Storage relative humidity | 5% to 95% noncondensing |
Weight | 5.0 lb (2.27 Kg) |
Ethernet Ports | 8 x 10/100/1000 Gigabit Ethernet |
Default Software | IP Base (IP Services with RTU License) |
Forwarding Bandwidth | 16 Gbps |
Memory DRAM | 512 MB |
Max VLANs | 1023 |
VLAN IDs | 4000 |
Jumbo frames | 9198 bytes |
Forwarding rate 64 Byte Packet | 17.9 mpps |
Operating* temperature up to 5000 ft (1524 m) | -5°C to +45°C (+23°F to +113°F) |
Operating* temperature up to 10,000 ft (3048 m) | -5°C to +45°C (+23°F to +113°F) |
Storage temperature up to 15,000 ft (4572 m) | -25°C to +70°C (-13°F to +158°F) |
PoE Output Ports | 8 PoE+ |
Available PoE Power | 240W |
Powering Option | Internal power supply |
Available PoE Power (W) | 240W |
Can Switch Be Powered with Uplinks | No |
Safety standards | UL 60950-1 CAN/CSA 22.2 No. 60950-1 EN 60950-1 IEC 60950-1 CE Marking GB 4943 IEC 60825 |
Electromagnetic emissions certifications | FCC Part 15, CFR 47, Class A, North America EN/IEC 61000-4-5 EN 55022 (CISPR22) and EN 55024 (CISPR24), CE marking, European Union AS/NZS, Class A, CISPR22:2004 or EN55022, Australia and New Zealand VCCI Class A, V-3/2007.04, Japan KCC (Formerly MIC, GB17625.1-1998) Class A, KN24/KN22, Korea ANATEL, Brazil CCC, China GOST, Russia |
Switching Bandwidth (full-duplex capacity) | 32 Gbps |