Specification
Slot orientation Vertical
Cisco ASR 9000 Series RSP Dual redundant RSPs with integrated fabric in 2 slots
Cisco ASR 9000 Series line cards 8 line-card slots
“Commons” components 2 RSPs
2 fan trays
2 PEMs (either DC or AC)
1 fan filter
Rack mounting 19-in. default
21- and 23-in. adapters available
Note: Minimum 17.75-in. opening between posts is needed for proper operation
Cabinet mounting Yes
Note: Doors not recommended in enclosed cabinets
Wall mounting No
Reliability and availability Fabric redundancy
Fan redundancy
Feed redundancy
Power-supply redundancy
RSP redundancy
Software redundancy
Fabric One per RSP:
Active/active nonblocking operation mode in dual-RSP redundant configuration
Fully redundant in dual-RSP redundant configuration
Built-in service-intelligence and traffic-prioritization capability
Thermal Two fan trays:
12 high-efficiency fans per tray
Variable-speed fans for optimal thermal performance
No single point of failure
Modularity Pay-as-you-grow power for future scalability, available in AC and DC.
Multiple power module types:
6 kW and 3 kW AC power modules
4.4 kW and 2.1 kW DC power modules
Note: Mixing of AC and DC modules is not supported
Power zones No power zone restrictions
Fully load-sharing power infrastructure
Power-module airflow Front-to-back
Storage temperature -40 to 158 F (-40 to 70 C)
Storage (relative humidity) 5 to 93%
ETSI standards Cisco ASR 9010 Routers are designed to meet:
EN300 386: Telecommunications Network Equipment (EMC)
ETSI 300 019 Storage Class 1.1
ETSI 300 019 Transportation Class 2.3
ETSI 300 019 Stationary Use Class 3.1
EMC standards emission Cisco ASR 9010 Routers are designed to meet:
FCC Class 47CFR15 A
ICES 003 Class A
AS/NZS CISRP22 Class A
CISPR 22 (EN55022) Class A
VCCI Class A
BSMI Class A
IEC/EN 61000-3-12: Power Line Harmonics
IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
EN55022: Information Technology Equipment (Emissions)
EN 50121-4: Railway EMC
EMC standards immunity Cisco ASR 9010 Routers are designed to meet:
IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
IEC/EN-61000-4-3: Radiated Immunity (10V/m)
IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
IEC/EN-61000-4-5: Signal Surge Ports (1kV)
IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
EN55024: Information Technology Equipment (Immunity)
EN50082-1/EN-61000-6-1: Generic Immunity Standard
EN 50121-4: Railway EMC
Redundancy AC: N+N redundancy
DC: N+1 redundancy
Power module redundancy
A/B Feed redundancy
PEM redundancy
Physical specifications Height: 36.75 in. (933.45 mm) (21 RU)
Width: 17.38 in. (441.45 mm)
Depth:
With doors: 29.03 in. (737.4 mm)
Without doors: 28.24 in. (717.3 mm)
Weight:
155.6 lb (70.73 kg) (chassis with PEM)
231.6 lb (105.27 kg) (fully loaded, excluding linecards and power modules) – RSP, two v2 fan trays, PEMs
Operating temperature (nominal) 41 to 104 F (5 to 40 C)
Operating humidity (nominal) (relative humidity) 5 to 90%
Description Cisco ASR 9010 chassis, ASR-9010-DC, ASR-9010 DC chassis
Power input Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)
Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
Airflow Front-to-back
Operating temperature (short-term) ASR 9006: 23 to 131 F (-5 to 55 C)
ASR 9010: 23 to 122 F (-5 to 50 C)
Safety Cisco ASR 9010 Routers are designed to meet:
UL/CSA/IEC/EN 60950-1
IEC/EN 60825 Laser Safety
ACA TS001
AS/NZS 60950
FDA Code of Federal Regulations Laser Safety
Network Equipment Building Standards (NEBS) Cisco ASR 9010 Routers are designed to meet:
SR-3580: NEBS Criteria Levels (Level 3)
GR-1089-CORE: NEBS EMC and Safety
GR-63-CORE: NEBS Physical Protection
VZ.TPR.9205: Verizon TEEER
Operating altitude -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)