+7 (812) 309 34 73

по будням с 10:00 до 18:00

ASR-9006-AC

Производитель: Cisco
Код товара: ASR-9006-AC Cisco ASR 9006 Series Chassis
Артикул: ART2905
По запросу
Сроки: 14 дней
Нашли дешевле?

+7 (812) 309 34 73. Договоримся!

Specification
Slot orientation Horizontal
Cisco ASR 9000 Series RSP Dual redundant RSPs with integrated fabric in 2 slots
Cisco ASR 9000 Series line cards 4 line-card slots
“Commons” components 2 RSPs
2 fan trays
1 PEM (either DC or AC)
1 fan filter
Rack mounting 19-in. default
21- and 23-in. adapters available
Note: Minimum 17.75-in. opening between posts is needed for proper operation
Cabinet mounting Yes
Note: Doors not recommended in enclosed cabinets
Wall mounting No
Reliability and availability Fabric redundancy
Fan redundancy
Feed redundancy
Power-supply redundancy
RSP redundancy
Software redundancy
Fabric One per RSP:
· Active/active nonblocking operation mode in dual-RSP redundant configuration
· Fully redundant in dual-RSP redundant configuration
· Built-in service-intelligence and traffic-prioritization capability
Thermal Two fan trays:
· 6 high-efficiency fans per tray
· Variable-speed fans for optimal thermal performance
· No single point of failure
Modularity Pay-as-you-grow power for future scalability, available in AC and DC.
Multiple power module types:
· 3 kW AC power module
· 2.1 kW DC power module
Note: Mixing of AC and DC modules is not supported
Power zones No power zone restrictions
Fully load-sharing power infrastructure
Power-module airflow Front-to-back
Storage temperature -40 to 158 F (-40 to 70 C)
Storage (relative humidity) 5 to 93%
ETSI standards Cisco ASR 9006 is designed to meet:
· EN300 386: Telecommunications Network Equipment (EMC)
· ETSI 300 019 Storage Class 1.1
· ETSI 300 019 Transportation Class 2.3
· ETSI 300 019 Stationary Use Class 3.1
EMC standards emission Cisco ASR 9006 is designed to meet:
· FCC Class 47CFR15 A
· ICES 003 Class A
· AS/NZS CISRP22 Class A
· CISPR 22 (EN55022) Class A
· VCCI Class A
· BSMI Class A
· IEC/EN 61000-3-12: Power Line Harmonics
· IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
· EN55022: Information Technology Equipment (Emissions)
· EN 50121-4: Railway EMC
EMC standards immunity Cisco ASR 9006 is designed to meet:
· IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
· IEC/EN-61000-4-3: Radiated Immunity (10V/m)
· IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
· IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
· IEC/EN-61000-4-5: Signal Surge Ports (1kV)
· IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
· IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
· IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
· IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
· EN55024: Information Technology Equipment (Immunity)
· EN50082-1/EN-61000-6-1: Generic Immunity Standard
· EN 50121-4: Railway EMC
Redundancy · AC: N+N redundancy
· DC: N+1 redundancy
· Power module redundancy
· A/B Feed redundancy
Physical specifications Height: 17.50 in. (444.5 mm) (10 RU)
Width: 17.38 in. (441.45 mm)
Depth:
· With doors: 29.05 in. (737.9 mm)
· Without doors: 29.05 in. (737.9 mm)
Weight:
· 89.55 lb (40.7 kg) (chassis with PEM)
150 lb (65.91 kg) (fully loaded, excluding line cards and power modules) – RSP, two v2 FAN trays, PEMs
Operating temperature (nominal) 41 to 104 F (5 to 40 C)
Operating humidity (nominal) (relative humidity) 5 to 90%
Description Cisco ASR 9006 Chassis, ASR-9006-AC, ASR-9006 AC Chassis
Power input Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)
Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
Airflow Right-to-back, Front-to-back with baffle
Operating temperature (short-term) ASR 9006: 23 to 131 F (-5 to 55 C)
ASR 9010: 23 to 122 F (-5 to 50 C)
Safety Cisco ASR 9006 is designed to meet:
· UL/CSA/IEC/EN 60950-1
· IEC/EN 60825 Laser Safety
· ACA TS001
· AS/NZS 60950
· FDA Code of Federal Regulations Laser Safety
Network Equipment Building Standards (NEBS) Cisco ASR 9006 is designed to meet:
· SR-3580: NEBS Criteria Levels (Level 3)
· GR-1089-CORE: NEBS EMC and Safety
· GR-63-CORE: NEBS Physical Protection
· VZ.TPR.9205: Verizon TEEER
Operating altitude -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
  Написать отзыв